Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

04/02/2012

Applicant:

LEMKE DAVID L & BETTY M JT/RS

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T12DV02531
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
06/06/2012 NPO(EL)-MAIN/PANEL/SUB/DISCONT WNAVARRO Follow-up inspection
06/06/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX WNAVARRO Follow-up inspection
06/06/2012 NPO(DL)-DILAPIDATED STRUCTURE WNAVARRO Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T12DV02531
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/30/2012 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved EMERGENCY CALL BY TFD, HOUSE FIRE THERE WAS FIRE DAMAGE TO THE LAUNDRY ROOM'S INTERIOR FRAMING MEMBERS SUCH AS THE WALL STUDS AND THE ROOF RAFTERS WHICH DO EXTEND TO THE MAIN GARAGE AREA. THE LAUNDRY ROOM ABUTS A STORAGE ROOM WHICH ARE ALL PART OF TE ATTACHED GARAGE. THESE ROOMS ARE SEPARATED BY PARTITIONED WOOD FRAMED WALLS. THE GARAGE ROOF HAS THREE 4X4 ROOF CUT OUTS. PHOTOS IN SIRE. THE INTERIOR OF THE KITCHEN'S CEILING HAS AN INSPECTION 4X4 DRYWALL CUT OUT. THE POWER WAS CUT BY TEP. THE MAIN DISCONNECT IS LOCATED ON THE EXTERIOR LAUNDRY ROOM'S WALL, ALL THE DWELLINGS HOME RUNS ENTER THE LAUNDRY ROOM AND EXIT IN THE FIRE DAMAGED AREA. PERMITS ARE REQUIRED FOR ALL REPAIRS, A NOTICE AND ORDER WAS ISSUED AND SIGNED BY THE PROPERTY OWNER BETTY LEMKE ON SITE. THE DWELLING UNIT COULD BE SECURED BY ITS OWN WINDOW AND DOOR'S. THE CITY DID NOT SECURE THE STRUCTURE. SCHEDULE A 60 DAY FOLLOW UP INSPECTION FOR THE ARE INSPECTOR.
06/05/2012 INSP - FOLLOW UP CODE ENFORCE WNAVARRO Approved VISITED SITE. INSPECTED, FOUND A COMPANY CALLED DAMAGE CONTROL RESTORATION DEMOLISHED BURNT PART OF BUILDING AND WILL RESEARCH

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T12DV02531
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
06/06/2012 CONTACTED BY PHONE
04/02/2012 CONTACTED IN PERSON
04/02/2012 NOTICE AND ORDER ISSUED
04/11/2013 VIOLATION CLOSED
06/06/2012 RESEARCH
04/02/2012 CALLBACK

Documents

File Name Document Type  
P3190041.JPG DOCUMENTS VIEW
P3190042.JPG DOCUMENTS VIEW
P3190043.JPG DOCUMENTS VIEW
P3190044.JPG DOCUMENTS VIEW
P3190045.JPG DOCUMENTS VIEW
P3190046.JPG DOCUMENTS VIEW
DAMAGEREPORTDOCUMENTS DOCUMENTS VIEW