Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T12DV00519
Case Details
Entered Date:
01/26/2012
Applicant:
IB PROPERTY HOLDINGS LLC: ATT: MONICA
Description:
#26102 - door in apt falls off hinges. wire hanging out of wall for smoke detector. sliding door does not lock properly. someone is home late afternoon.
Case Violations
Case Number: T12DV00519
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date | Code Statue |
---|---|
02/03/2012 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
02/03/2012 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
02/03/2012 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (1) Dwelling units shall be provided with one or more bathrooms equipped with a water closet, lavatory, and either a bathtub or shower. The number of water closets and lavatories for commercial buildings shall be determined by the International Building Code based on the use of the building. Each sink, bathtub and shower shall have hot and cold running water as necessary for its normal operation and use. |
02/03/2012 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
02/03/2012 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
02/03/2012 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
Outstanding Inspections
Case Number: T12DV00519
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/20/2012 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | WNAVARRO | Item closed | |
03/20/2012 | NPO(PL)-PLUMBING SYSTEM & FX | WNAVARRO | Item closed | |
03/20/2012 | NPO - INSECTS/PESTS | WNAVARRO | Item closed | |
03/20/2012 | NPO - SMOKE ALARMS | WNAVARRO | Item closed | |
03/20/2012 | NPO - INT. BUILDING MAINTENANC | WNAVARRO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T12DV00519
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/01/2012 | INSP - INITIAL CODE ENFORCMENT | WNAVARRO | Approved | VISITED SITE, MET TENANT, INSPECTED UNIT, FOUND AS FOLLOWSRANGE HOOD FAN FALLING OFF MOTOR, ARCADIA DOOR OUT OF PLUMB- NEEDS ADJUSTMENT TO PROPERLY SHUT AND LOCK,, SECOND FLOOR STAIRWAY SHEETROCK AT BASE IS DETERIORATED AND NEEDS REPLACED AND PAINTED, WATER CLOSET LEAKS AT BASE, BASIN CABINENT IS DETERRIORATED AND POSES A SAFETY HAZARD TO TENANTS, CLOSET DOORS IN SEVERAL BEDROOMS ARE OUT OF PLUMB AND NEEDS ADJUSTMENT, SWITCH FOR LIGHT IN BEDROOM DOES NOT OPERATE PROPERLY IN BEDROOM, SEVERAL ELECTRICAL OUTLETS ARE WORN AND DOES NOT HOLD APPLIANCE CORDS AND POSE A SAFETY HAZARD TO THE TENANTS, ALL SMOKE DETECTORS DO NOT OPERATE PROPERLY, THE TUB DIVERTER IS BROKEN AND HEEDS REPAIR OR REPLACED, ALSO HAS A COCKROACH INFESTATION, CONTACTED MANAGEMENT AND EXPLAINED THE VIOLATIONS AND PROCESS OF THE NOTICE OF VIOLATION WILL WRITE NOTICE OF VIOLATION |
03/20/2012 | INSP - FOLLOW UP CODE ENFORCE | WNAVARRO | Approved | VISITED SITE, INSPECTED, FOUND UNIT REPAIRED AND IN COMPLIANCE, CASE CLOSED ABATED |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T12DV00519
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
02/08/2012 | CONTACTED BY MAILING |
02/08/2012 | NOTICE OF VIOLATION ISSUED |
03/23/2012 | VIOLATION CLOSED |