Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Case Details

Status:

COURTCMP

Type:

RES: MINIMUM HOUSING

Entered Date:

01/25/2012

Applicant:

HEIDI D. & SERGIO R. ALVAREZ

Description:

No heating. Owner took the two portable heaters on 1/24/12. Electricty inside the home flickers and goes on and off at times. Plumbing is bad. Problems reported to owner with no repairs.

Case Violations

Case Number: T12DV00497
Case Status: COURTCMP
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date Code Statue
02/08/2012 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
02/08/2012 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
02/08/2012 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
02/08/2012 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation.
02/08/2012 T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height; (2) All weeds that exceed 6 inches in height; (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten feet of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries. Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade.
02/08/2012 T.C. Ch. 16, Sec. 16-13(d) DUTY TO REMOVE WEEDS AND REFUSE FROM ABUTTING SIDEWALKS, STREETS AND ALLEYS UPON NOTICE. Upon receipt of notice served pursuant to section 16-45, the owner, lessee, tenant or occupant of any premises shall remove from the premises and the abutting portions of contiguous sidewalks, streets and alleys, all weeds, garbage, debris or other refuse which may endanger the health, safety or welfare of the persons in the vicinity of such premises. This duty extends to and includes any abutting sidewalk area and one-half (½) the width of abutting alleys, from the property line to the center line of the alley.

Outstanding Inspections

Case Number: T12DV00497
Case Status: COURTCMP
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 9
End Date Description Inspector Results Comments
10/10/2012 LUC - ILLEGAL HOME OCCUPATION ESTEVENS Item closed
10/10/2012 NPO - SMOKE ALARMS ESTEVENS Item closed
10/10/2012 NPO - JUNKED/INOP. VEHICLE(S) ESTEVENS Item closed
10/10/2012 NPO - VEGETATION NUISANCE ESTEVENS Item closed
10/29/2012 NPO(EL)-MAIN/PANEL/SUB/DISCONT ESTEVENS Citation
10/29/2012 NPO(EL)-WIRING/SWITCH/OUTLT/FX ESTEVENS Citation
10/29/2012 NPO(PL)-PLUMBING SYSTEM & FX ESTEVENS Citation
10/29/2012 NPO(HC)-HEATING & VENTILATION ESTEVENS Citation
10/29/2012 NPO - INT. BUILDING MAINTENANC ESTEVENS Citation

Completed Inspections

Case Status: COURTCMP
Case Number: T12DV00497
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/27/2012 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VIOLATIONS PRESENT Site inspection, met w/tenant & owner also present was inspectors supervisor. Walked exterior & interior of 3 units, overgrown, unattended vegetation exceeding 6" in height through out property & along outside of fencing. Unit 1, 2317, Electrical issues, exterior receptacle lacking weather proof cover, J-box lacks cover plate below roof overhang, all receptacles tested, some lacking required grounding, some in bed rm not working, no G.F.C.I. in kitchen. Gas furnace not operable & tagged by SW gas Co. H.W.H. lacking T.R.P. drain pipe. Tub not draining. Unit 2, 2317 lacks required smoke detectors and is storing combustible in front of gas H.W.H. & furnace area. Unit 3, 2319 (B) lacks required smoke detectors, H.W.H. lacking T.R.P. drain piping & unit lacking required heating appliance.
12/10/2012 INSP - FOLLOW UP CODE ENFORCE ESTEVENS Approved At site, both units vacant. Called owner, Sergio. He stated that the property was going to go into foreclosure. Posted both units "keep vacant" F/U 90 days.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T12DV00497
Case Status: COURTCMP
Total Completed Case Activity Conditions: 9
Date Name
02/08/2012 CONTACTED BY PHONE
02/10/2012 CONTACTED BY MAILING
11/28/2012 PROCESS SERVED
02/08/2012 NOTICE OF VIOLATION ISSUED
10/29/2012 CITATION ISSUED
01/22/2013 VIOLATION CLOSED
10/29/2012 COURT HEARING INFO
02/08/2012 RESEARCH
10/17/2012 REINSPECTION FEE - FIRST

Documents

File Name Document Type  
None IMAGES VIEW
2317 E SUNLAND VISTA.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW
2317 E SUNLAND VISAT NOV.PDF DOCUMENTS VIEW
CITATION 6880740.PDF DOCUMENTS VIEW
CITATION 6880739.PDF DOCUMENTS VIEW
CITATION#6880749 PROCESS SERVER DOCUMENTS VIEW
AFF OF SERVICE - CIT6880749 DOCUMENTS VIEW