Case: T11DV08506
Case Details
Entered Date:
10/18/2011
Applicant:
GERALD L. & BARBARA PELLAND & ARNULFO J. & YOLANDA C. ROBLES
Description:
Fire Hazard/Electric breaker box not up to code.
Case Violations
Case Number: T11DV08506
Case Status: COURTCMP
Case Description: RESIDENTIAL ZONING
Total Violations: 1
Violation Date | Code Statue |
---|---|
11/02/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
Outstanding Inspections
Case Number: T11DV08506
Case Status: COURTCMP
Case Description: RESIDENTIAL ZONING
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/05/2011 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | JHURD | Extension granted | 30 days |
Completed Inspections
Case Status: COURTCMP
Case Number: T11DV08506
Case Description: RESIDENTIAL ZONING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/28/2011 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | VISITED SITE: TALKED WITH OCC. OF #129, NOT AWARE OF ISSUES, HE DID NOT MAKE COMPLAINT. DID ALLOW ME TO LOOK AROUND AT SERVICE. 1) BREAKERS NOT COMPATIBLE WITH SERVICE. 2) WEATHER HEAD TO SHORT. 3) 30 AMP. BREAKERS TO SMALL BE TODAY'S STANDARDS, NOT ENOUGH TO SERVICE ITEMS. 4) USING ZIP CORD TO SERVICE COOLER. 5) OPEN EXPOSED ROMEX 6) SERVICE LINE FROM 129 SERVICE PANEL TO UNIT 131 WAY TO SHORT. APPROX. 7' FROM GRADE, REQUIRES MIMINUM 12' 7) SUB PANELS SCREW IN FUSES OVER PROTECTED. 8) INTERIOR CONVENIENCE OUTLET 3 PRONG ON 2 WIRE SYSTEM. SHOWS OPEN GROUND UNDER TEST. 9) #135 HOT WATER TANK REPLACED WITH NEW, NO PERMIT SECURED. ALL ISSUES MENTIONED ABOVE CREATE A HAZARDOUS CONDITION. N/O/V TO BE ISSUED AFTER RESEARCH. (P.D.S.D). SEE COND. |
11/03/2011 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | VISITED SITE: MET WITH OWNERS, WENT OVER ALL ISSUES, HAND DELIVERED N/O/V. ELECTRICAL ISSUES. FOLLOW UP 30 DAYS. |
Completed Activity Special Conditions
Case Description - RESIDENTIAL ZONING
Case Number - T11DV08506
Case Status: COURTCMP
Total Completed Case Activity Conditions: 10
Date | Name |
11/01/2011 | CONTACTED BY PHONE |
03/13/2013 | CONTACTED BY MAILING |
03/25/2013 | CERTIFIED RECEIPT CARD |
11/07/2011 | NOTICE OF VIOLATION ISSUED |
03/13/2013 | CITATION ISSUED |
06/06/2013 | VIOLATION CLOSED |
05/14/2013 | COURT HEARING INFO |
11/02/2011 | RESEARCH |
08/29/2012 | REINSPECTION FEE - FIRST |
08/29/2012 | REINSP LETTER SENT |