Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COURTCMP

Type:

RESIDENTIAL ZONING
Address:

Entered Date:

10/18/2011

Applicant:

GERALD L. & BARBARA PELLAND & ARNULFO J. & YOLANDA C. ROBLES

Description:

Fire Hazard/Electric breaker box not up to code.

Case Violations

Case Number: T11DV08506
Case Status: COURTCMP
Case Description: RESIDENTIAL ZONING
Total Violations: 1
Violation Date Code Statue
11/02/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T11DV08506
Case Status: COURTCMP
Case Description: RESIDENTIAL ZONING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
12/05/2011 NPO(EL)-MAIN/PANEL/SUB/DISCONT JHURD Extension granted 30 days

Completed Inspections

Case Status: COURTCMP
Case Number: T11DV08506
Case Description: RESIDENTIAL ZONING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/28/2011 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE: TALKED WITH OCC. OF #129, NOT AWARE OF ISSUES, HE DID NOT MAKE COMPLAINT. DID ALLOW ME TO LOOK AROUND AT SERVICE. 1) BREAKERS NOT COMPATIBLE WITH SERVICE. 2) WEATHER HEAD TO SHORT. 3) 30 AMP. BREAKERS TO SMALL BE TODAY'S STANDARDS, NOT ENOUGH TO SERVICE ITEMS. 4) USING ZIP CORD TO SERVICE COOLER. 5) OPEN EXPOSED ROMEX 6) SERVICE LINE FROM 129 SERVICE PANEL TO UNIT 131 WAY TO SHORT. APPROX. 7' FROM GRADE, REQUIRES MIMINUM 12' 7) SUB PANELS SCREW IN FUSES OVER PROTECTED. 8) INTERIOR CONVENIENCE OUTLET 3 PRONG ON 2 WIRE SYSTEM. SHOWS OPEN GROUND UNDER TEST. 9) #135 HOT WATER TANK REPLACED WITH NEW, NO PERMIT SECURED. ALL ISSUES MENTIONED ABOVE CREATE A HAZARDOUS CONDITION. N/O/V TO BE ISSUED AFTER RESEARCH. (P.D.S.D). SEE COND.
11/03/2011 INSP - FOLLOW UP CODE ENFORCE JHURD Approved VISITED SITE: MET WITH OWNERS, WENT OVER ALL ISSUES, HAND DELIVERED N/O/V. ELECTRICAL ISSUES. FOLLOW UP 30 DAYS.

Completed Activity Special Conditions

Case Description - RESIDENTIAL ZONING
Case Number - T11DV08506
Case Status: COURTCMP
Total Completed Case Activity Conditions: 10
Date Name
11/01/2011 CONTACTED BY PHONE
03/13/2013 CONTACTED BY MAILING
03/25/2013 CERTIFIED RECEIPT CARD
11/07/2011 NOTICE OF VIOLATION ISSUED
03/13/2013 CITATION ISSUED
06/06/2013 VIOLATION CLOSED
05/14/2013 COURT HEARING INFO
11/02/2011 RESEARCH
08/29/2012 REINSPECTION FEE - FIRST
08/29/2012 REINSP LETTER SENT

Documents

File Name Document Type  
CITATION(S) 6885180, 6884926-6884928.PDF DOCUMENTS VIEW
NOV T11DV08506 11-3-11.PDF DOCUMENTS VIEW