Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

CANCEL

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

09/16/2011

Applicant:

AMY S. COLES

Description:

Exposed wiring in one of the bathrooms. Shower has no doors. There is a curtain in the shower that is too short in length. Water flows out of the shower onto the bathroom floor when used. Locks to the main door have not been repaired/replaced for over a month. Venelation into one of the bedrooms is not good. (There may be an illegal addition of one the bedroom with bad venelation.)

Case Violations

Case Number: T11DV07415
Case Status: CANCEL
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
Violation Date Code Statue
11/01/2011 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
11/02/2011 T.C. Ch. 16, Sec. 16-11(a)(2) Every dwelling unit or guest room shall have unobstructed access directly to the outside, or to a public corridor. Every door, stairway, passageway or other means of exit shall be of sufficient size, width and arrangement so as to provide safe and rapid egress in the event of fire. Every walking surface of any means of exit shall be maintained free of warping, rotting, or other damage or obstructions so as to provide safe and rapid egress in the event of fire.

Outstanding Inspections

Case Number: T11DV07415
Case Status: CANCEL
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
10/04/2011 NPO(HC)-NO VENTILATION HLOPEZ Item closed
12/08/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Follow-up inspection
12/08/2011 NPO - WORK WITHOUT PERMIT HLOPEZ Follow-up inspection
12/08/2011 NPO - INT. BUILDING MAINTENANC HLOPEZ Follow-up inspection

Completed Inspections

Case Status: CANCEL
Case Number: T11DV07415
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/04/2011 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VIOLATION PRESENT Site inspection, contact made w/tenants. Insp. allowed entry, person making complaint not present, was contacted by phone, issues reviewed, shower curtain to short, striker plate for back door missing. double keyed dead bolt lock installed at wrought iron door. J-box installed above shower not installed per code requirements, use of unapproved electrical conductors & conductors are not protected. Improper penetration through wall, knock out missing from j-box. Hot water heated lacks T.P.R.V. drain line & improper installation of flue piping & cap. (not above roof line) Possible w/o/p, back porch enclosed for habitable space w/addition of bathroom. Insp. to ck for electrical up-grade. All interior receptacles ck out good. Service panel lacks directory. Contact made w/realtor, stated several attempts made to do corrections, tenants have not allowed entry to address issues. Shower curtain & new rod have been ready to install. Research required prior to issuing NOV.
12/08/2011 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved RESEARCH PDSD / PERMIT T11CM03666 APPLIED 11/30/11, case moving forward, fw/up in 30 days

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T11DV07415
Case Status: CANCEL
Total Completed Case Activity Conditions: 7
Date Name
01/20/2012 CONTACTED BY PHONE
11/08/2011 CONTACTED BY MAILING
02/21/2012 CONTACTED BY EMAIL
11/08/2011 NOTICE OF VIOLATION ISSUED
04/04/2012 CITATION ISSUED
11/01/2011 RESEARCH
04/04/2012 REINSPECTION FEE - FIRST

Documents

File Name Document Type  
CITATION 6885271_4-5-12.PDF DOCUMENTS VIEW