Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T11DV05415
Case Details
Entered Date:
07/18/2011
Applicant:
JOE Y & LORI J LILLEY
Description:
#13 ---> holes in floor and wife fell through floor. walls with holes and can see outside. wires exposed to thermostat. roof leaks. water faucets exploded.
Case Violations
Case Number: T11DV05415
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 9
| Violation Date | Code Statue |
|---|---|
| 07/27/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 07/27/2011 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
| 07/27/2011 | T.C. Ch. 16, Sec. 16-12(d) COOLERS. Evaporative coolers, cooler stands, and any cooler mounting apparatus must be maintained in a safe condition. Cooler stands and any mounting apparatus must be structurally sound. |
| 07/27/2011 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition. |
| 07/27/2011 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 07/27/2011 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 07/27/2011 | T.C. Ch. 16, Sec. 16-11(f)(1) Every wall or vertical support must be sufficient to carry imposed loads safely, and must not lean, buckle, or split due to defect or lack of maintenance. |
| 07/27/2011 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 07/27/2011 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
Outstanding Inspections
Case Number: T11DV05415
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/29/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO(PL)-PLUMBING SYSTEM & FX | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO(HC)-COOLING | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO - OTHER | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO - EXT. BUILDING MAINTENANC | JHURD | Follow-up inspection | |
| 12/29/2011 | NPO - INT. BUILDING MAINTENANC | JHURD | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV05415
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/26/2011 | INSP - INITIAL CODE ENFORCMENT | JHURD | Approved | UNIT # 13 VISITED SITE: MET W/ OCCUPANT. (PIC'S) FRONT ENTRY STEP TREADS LOOSE. FRONT PORCH LIGHT HANGING BY WIRES. 1 WIRE DISCONNECTED, ELECT. ENERGIZED. FRONT DOOR LACKS PROPER WEATHER PROPECTION, WEATHERSTRIPPING HANGING FROM DOOR. KITCHEN LIGHT FIXTURE LACKS REQUIRED COVER. COOK STOVE EXHAUST FAN DOES NOT OPERATE AS INTENDED. LIVINGROOM COOLER LACKS REQUIRED PROTECTIVE COVER. OPENING TO INTERIOR FAN. FLOOR SHOWS SEVERAL WEAK SPOTS THROUGH OUT UNIT. HALLWAY WALL WHERE MEETS FLOOR DETERIORATED FROM WATER LEAK. PATCHWORK/REPAIR NOT AN ACCEPTABLE METHOD, FOAM.. CONVENIENCE OUTLETS LOOSE, SOME DO NOT OPERATE AS INTENDED. THROUGHOUT. BEDROOM 1) LACKS REQUIRED ACCEPTABLE MEANS OF EGRESS. BUNK BEDS BLOCK ANY AND ALL EGRESS. SOUTH WALL UNDER WINDOW DETERIORATED DUE TO WATER LEAK. CONVENIENCE OUTLET ON SOUTH WALL UNDER WINDOW SHOWS DETERIORATION DUE TO WATER LEAKING IN OUTLET. BEDROOM 2) WINDOW AND FRAME BROKEN. LEAKS WHEN RAINS. BATHROOM 2 HOLES IN DOOR. BATHROOM SINK CONTINOUSLY LEAKS. BATHROOM SINK VANITY INTERIOR BOTTOM DETERIORATED DUE TO WATER LEAK. WRONG APPLICATION OF REPAIR. BATH VANITY DRAWERS BROKEN OR MISSING. BATH TUB/SHOWER DOORS BROKEN, FRAME/SEAL OFF DOORS. TUB/ SHOWER AREA WALLS LACKS REQUIRED PROTECTIVE COVERING. WATER DETERIORATION. HALLWALL INTERIOR WALL DETERIORATED, HOLE COVER WITH CARDBOARD & TAPE. WHERE WALL MEETS FLOOR DETERIORATED. CONVENIENCE OUTLET DOES NOT OPERATE, RAN WIRE OUT OF OUTLET BOX. ELECTRICAL SUB-PANEL RE-LOCATED INTO HOT WATER HEATER ROOM. LACKS REQUIRED SPACING FOR ANY AND ALL REPAIR WORK. HOT WATER HEATER REPLACED NOT A MOBILE HOME HOT WATER HEATER. LACKS EMERGENCY COLD WATER SHUT OFF. HOT WATER TANK ENCLOSER ROOM LACKS DOOR. HOT WATER TANK ROOM FLOOR DETERIORATED FROM WATER LEAK, HOLES ALLOWS FOR ANIMALS TO ENTER LIVING SPACE. ELECTRICAL LIFE LINE CORD TO SHORT. ALUMINUM FROM SKIRTING SHARP EDGES ON LIFE LINE CORD. |
| 12/29/2011 | INSP - FOLLOW UP CODE ENFORCE | JHURD | Approved | VISITED SITE: REQUIRES INTERIOR INSP. NO ENTRY. FOLLOW UP 30 DAYS. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T11DV05415
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 08/19/2011 | CONTACTED IN PERSON |
| 08/10/2011 | CONTACTED BY MAILING |
| 08/10/2011 | NOTICE OF VIOLATION ISSUED |
| 10/12/2012 | VIOLATION CLOSED |
| 10/17/2011 | REINSPECTION FEE - FIRST |