Case Details

Status:

COMPLIAN

Type:

SIGN VIOLATION

Entered Date:

07/08/2011

Applicant:

MARY L. BOATNER

Description:

Illegal signs and banners on building and in drive thru

Case Violations

Case Number: T11DV05204
Case Status: COMPLIAN
Case Description: SIGN VIOLATION
Total Violations: 1
Violation Date Code Statue
08/02/2011 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T11DV05204
Case Status: COMPLIAN
Case Description: SIGN VIOLATION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
09/09/2011 SIGN - ILLEGAL SIGN HLOPEZ Item closed
11/18/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX HLOPEZ Extension granted 30 days
11/18/2011 NPO - WORK WITHOUT PERMIT HLOPEZ Extension granted 30 days

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV05204
Case Description: SIGN VIOLATION
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/22/2011 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VIOLATIONS PRESENT Site inspection found large amounts of illegal poster signs attached to structure & poles by drive through window. Also evidence of w/o/p, roof structure for drive through lane recently rebuilt, structure measures approx. 12'x18' roof framing built by using 2"x4" and are over spanned, 1-4"x4" along south side was spliced together and installed w/metal brace & section of 4"x4" post nailed to roof to support beam. Exterior light fixture added , j-boxes are open, lacking cover plates and electrical conductor penetrating main structure roof is not in conduit. Contact made w/store operator. reviewed violations & abatement process. NOV issues for illegal signs & excessive banners. 30 days to abate & amended nov to follow for w/o/p.
11/18/2011 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved COMPLIANCE INSP. Site visited, contact made w/tenant, stated plans to be submitted monday 11/21/11. Work being scheduled. Case moving forward, 1 last 30 day extension given, if permit not in issued status by next inspection citiation will be issued. Tenant understood.

Outstanding Case Activity Conditions

Date Name Approved
08/02/2011 Notice of violation T11DV05204 issued 07/22/2011 has been amended to include the following listed violations. Not Approved

Completed Activity Special Conditions

Case Description - SIGN VIOLATION
Case Number - T11DV05204
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
09/15/2011 CONTACTED BY PHONE
08/16/2011 CONTACTED BY MAILING
08/16/2011 NOTICE OF VIOLATION ISSUED
01/19/2012 VIOLATION CLOSED
01/05/2012 RESEARCH
08/02/2011 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Documents

File Name Document Type  
NOV 7-22-11.PDF DOCUMENTS VIEW