Case: T11DV04363
Case Details
Entered Date:
06/13/2011
Applicant:
DINA WESTERMEYER
Description:
Currently no A/C. Has been an ongoing issue for approx. 6 weeks. Last night spoke with manager and was told someone would be out today to repair again & no one has gone out. Note: Inspector please contact Occupant prior to going out to ensure entry.
Case Violations
Case Number: T11DV04363
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 06/13/2011 | T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced. |
| 06/13/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 06/13/2011 | T.C. Ch. 16, Sec. 16-11(f)(1) Every wall or vertical support must be sufficient to carry imposed loads safely, and must not lean, buckle, or split due to defect or lack of maintenance. |
| 06/13/2011 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
| 06/13/2011 | T.C. Ch. 16, Sec. 16-13(f) BURNING OF REFUSE PROHIBITED. Except as specifically permitted by this or other adopted codes, the open burning or incineration of refuse is prohibited. |
| 06/14/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (3) Every habitable room must have at least two electrical receptacle outlets, or one outlet and one electric light fixture. Every bathroom, water closet compartment, and laundry room must have at least one electric light fixture. |
Outstanding Inspections
Case Number: T11DV04363
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected | ||
| 08/15/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | DJOHNSTO | Item closed | |
| 08/15/2011 | NPO(HC)-COOLING | DJOHNSTO | Item closed | |
| 08/15/2011 | NPO - INT. BUILDING MAINTENANC | DJOHNSTO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV04363
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/13/2011 | INSP - INITIAL CODE ENFORCMENT | ASMITH | Approved | Inspection found that the A/C unit was not working; but the manager has been working the issue all weekend long, they have had a number of issue with the compressor going bad( 2 times). There are a number of other issues with the unit. The outlets in the living room and loft are not work. The circit breckers seem to be lose when you re-set them, there are holes in the wall in the living and doors in the bed rooms. They are storing hazdous cleaners near the furnaces and boxs are blocking the return air duct. Have talked to manager and owner about the issues. manager will have an electrcian there with in the hour to check the outlets and the breckers. NOV will be sent. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T11DV04363
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 08/15/2011 | CONTACTED BY PHONE |
| 06/22/2011 | CONTACTED BY MAILING |
| 06/22/2011 | NOTICE OF VIOLATION ISSUED |
| 08/16/2011 | VIOLATION CLOSED |