Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T11DV03383
Case Details
Entered Date:
05/10/2011
Applicant:
EDDIE COLLINS
Description:
Report of unauthorized workers doing electrical, plumbing, and other maintenance on the trailers and to the main property office. Caller states you can smell gas in the park. Also there is trash and "junk" all over the property.
Outstanding Inspections
Case Number: T11DV03383
Case Status: REFERRED
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 8
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/29/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LPUMPHRE | Item closed | |
06/29/2011 | NPO(PL)-PLUMBING SYSTEM & FX | LPUMPHRE | Item closed | |
06/29/2011 | NPO(PL)-SEWAGE DISPOSAL (SYS) | LPUMPHRE | Item closed | |
06/29/2011 | NPO(PL)-WATER HEATERS | LPUMPHRE | Item closed | |
06/29/2011 | NPO - EXT. BUILDING MAINTENANC | LPUMPHRE | Item closed | |
06/30/2011 | NPO - REFUSE/TRASH/DEBRIS | LPUMPHRE | Citation | |
06/30/2011 | NPO - ILLEGAL DUMPING | LPUMPHRE | Citation | |
06/30/2011 | NPO - WORK WITHOUT PERMIT | LPUMPHRE | Citation |
Completed Inspections
Case Status: REFERRED
Case Number: T11DV03383
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2011 | INSP - INITIAL CODE ENFORCMENT | LPUMPHRE | Approved | L. Pumphrey and J. Hurd at unit #34 for inspection. Accumulation of refuse and debris on property. Water service piping from meter to trailer is PVC pipe, is leaking and not bonded. Water heater not installed to code: heater is not rated for trailer use, electrical connections are exposed and connected to extension cord running into interior of trailer, TPRV valve not installed properly, water connections leaking. Sewer piping is not supported under trailer and sits on bricks in places, with several ups and downs along length. Air conditioning unit on rear of trailer connected with extension cord instead of permanent wiring. Cooler on front of unit is also connected with extension cord; support is dilapidated. Boarded window on west side of trailer. |
06/29/2011 | INSP - FOLLOW UP CODE ENFORCE | LPUMPHRE | Approved | No compliance; large piles of refuse (demolished trailer) is left on lot. Demolition without permit. Citation will be issued to Eddie Collins. Owner has posted a forcible detainer summons on the property with the court date set at 7/1/11. |
Outstanding Case Activity Conditions
Date | Name | Approved |
05/10/2011 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. | Not Approved |
05/10/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. | Not Approved |
05/10/2011 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. | Not Approved |
05/10/2011 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. | Not Approved |
05/10/2011 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. | Not Approved |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T11DV03383
Case Status: REFERRED
Total Completed Case Activity Conditions: 3
Date | Name |
06/14/2011 | CONTACTED BY PHONE |
05/10/2011 | NOTICE OF VIOLATION ISSUED |
06/30/2011 | CITATION ISSUED |