Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T11DV03383
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/05/2011 | INSP - INITIAL CODE ENFORCMENT | Approved | L. Pumphrey and J. Hurd at unit #34 for inspection. Accumulation of refuse and debris on property. Water service piping from meter to trailer is PVC pipe, is leaking and not bonded. Water heater not installed to code: heater is not rated for trailer use, electrical connections are exposed and connected to extension cord running into interior of trailer, TPRV valve not installed properly, water connections leaking. Sewer piping is not supported under trailer and sits on bricks in places, with several ups and downs along length. Air conditioning unit on rear of trailer connected with extension cord instead of permanent wiring. Cooler on front of unit is also connected with extension cord; support is dilapidated. Boarded window on west side of trailer. |