Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

04/05/2011

Applicant:

MYRNA G RUIZ

Description:

TFD REQUEST FOR INSPECTOR / HOUSE FIRE

Case Violations

Case Number: T11DV02202
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Violations: 1
Violation Date Code Statue
07/15/2011 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T11DV02202
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
07/14/2011 NPO(EL)-MAIN/PANEL/SUB/DISCONT LPUMPHRE Follow-up inspection
07/14/2011 NPO(EL)-WIRING/SWITCH/OUTLT/FX LPUMPHRE Follow-up inspection
07/14/2011 NPO - INT. BUILDING MAINTENANC LPUMPHRE Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T11DV02202
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/02/2011 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved VISITED SITE, MET WITH TFD INVESTIGATORS, THEY MENTIONED THAT FIRE HAD STARTED IN THE S/W BEDROOM. FURTHER INSP BY TFD FOUND SMALL DRYER APPLIANCE CONNECTED TO A 50 FT CORD HAD ARCHED AT THE APPLIANCE/ CORD CONNECTION, CORD HAD NEW FEMALE END. END HAD BEEN REPLACED. CORD WAS KICKED UNDER THE BED WHICH CAUGHT FIRE WHEN THE APPLIANCE ARCED. TFD BROKE WINDOW AND CUT A HOLE IN THE ROOF/CEILING. TEP ARRIVED ONSITE AGREED THERE WAS NO REASON TO CUT POUER. S/W GAS ARRIVED ONSITE CONDUCTED LINE TEST AND CHECKED OUT APPLIANCES. CHECKED OUT OK. *INTERIOR OF STRUCTURE HAD A MINIMUM ONE INCH OF WATER THRU OUT THE STRUCTURE. *HEAVY SMOKE DAMAGE THRU OUT. * NEW GAS PACK INSTALLED ON THE ROOF WITHOUT PERMIT (CHECKED P+ AT LATER DATE) *ELECTRICAL SERVICE PANEL HAS MISMATCHED BREAKERS INSTALLED,ONE OR TWO INSTALLED INCORRECTLY. INTERIOR SUB-PANEL BURIED INSIDE KITCHEN CABINET. EXPOSED WIRING AT THE FAN ABOVE STOVE. EMERGENCY ORDER TO VACATE ISSUED FOR UNSAFE ELECTRICAL, UNSANITARY CONDITIONS (WATER AND SMOKE DAMAGE) , AND FIRE DAMAGE
07/14/2011 INSP - FOLLOW UP CODE ENFORCE LPUMPHRE Approved No compliance; no permits on file. Unable to assess occupancy. NOV will be sent requesting repairs under permit.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T11DV02202
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
07/15/2011 CONTACTED BY PHONE
07/25/2011 CONTACTED IN PERSON
04/06/2011 NOTICE AND ORDER ISSUED
04/06/2011 NOTICE OF VIOLATION ISSUED
02/02/2012 VIOLATION CLOSED
07/15/2011 RESEARCH

Documents

File Name Document Type  
INSPECTION NOTES.PDF DOCUMENTS VIEW
DAMAGE REPORT/EMERGENCY DOCS.PDF DOCUMENTS VIEW