Case: T11DV02091
Case Details
Entered Date:
03/31/2011
Applicant:
BRIAN J & MARGEAUX BOWERS
Description:
Back doors do not lock, hole in ceiling and walls, shower leaking into storage area, no ventelation, cooler doesnt work. Tenant has asked for repairs since Nov when he moved in.
Case Violations
Case Number: T11DV02091
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 04/06/2011 | T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced. |
| 04/06/2011 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 04/06/2011 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
| 04/06/2011 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 05/24/2011 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
Outstanding Inspections
Case Number: T11DV02091
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 6
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/19/2011 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Item closed | |
| 05/19/2011 | NPO - SMOKE ALARMS | RMENDOZA | Item closed | |
| 08/31/2011 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
| 08/31/2011 | NPO(HC)-COOLING | RMENDOZA | Item closed | |
| 08/31/2011 | NPO(HC)-HEATING & VENTILATION | RMENDOZA | Item closed | |
| 08/31/2011 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T11DV02091
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2011 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | WALL MOUNT HEATER NEAR FRONT WINDOW HAS BECOME DISLODGED. LIVING ROOM OUTLET IS MISSING COVER PLATE. FRONT DOOR SEAL IS INSUFFICIENT. CEILING IN THE HALLWAY IS DETERIORATED. DUCT WORK APPEARS TO BE PUSHING THROUGH THE CEILING DUE TO DETERIORATION. PLASTIC TUB IN THE PLENUM AREA. DUCT WORK IS SEVERLY DETERIORATED AND IS NOT ATTACHED IN AREAS. ELECTRICAL BOX ABOVE FRONT DOOR IS MISSING COVER PLATE. MAIN BEDROOM WALL AT VENT REGISTER IS DETERIORATED. WATER SHUT OFF IN NORTH BEDROOM CLOSET IS LEAKING. HAS BEEN SHUT OFF BUT STILL DRIPS. NORTH BEDROOM DOOR IS BROKEN. DOES NOT SHUT. BATHROOM SHOWER NOZZLE IS NOT PROPERLY SEALED ALLOWING WATER TO PENATRATE THE WALL. TILE GROUT THROUGHOUT THE SHOWER IS CRACKED AND NOT PROPERLY SEALED. CLEAR SILICONE HAS BEEN PLACED OVER MOLDED TILES. HOLE IN THE BATHROOM CEILING. STORAGE ROOM WEST WALL HAS A LARGE HOLE. STORAGE ROOM NORTH WALL IS DETERIORATED AND MOLDY FROM BATHTUB LEAKING. |
| 08/31/2011 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | ALL VIOLATIONS HAVE BEEN ABATED. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T11DV02091
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
| Date | Name |
| 04/07/2011 | CONTACTED BY PHONE |
| 04/08/2011 | CONTACTED BY MAILING |
| 04/08/2011 | NOTICE OF VIOLATION ISSUED |
| 09/20/2011 | VIOLATION CLOSED |
| 04/06/2011 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 04/06/2011 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 04/06/2011 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |