Case: T10FR02631
Case Details
Entered Date:
12/14/2010
Applicant:
DELTA BETA HOUSE LLC
Description:
FULL FIRE INSPECTION
Completed Inspections
Case Status: COMPLETE
Case Number: T10FR02631
Case Description: INSPECTION
Total Completed Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/14/2010 | VIOL - MEANS OF EGRESS | JVINCENT | Approved | 1008.1.8.5 Unlatching. The unlatching of any door or leaf shall not require more than one operation. 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. 1028.8 Panic hardware. Where panic and fire exit hardware is installed, the panic or fire exit hardware shall be the only locking device on the door except where otherwise permitted in this code. ____REMOVE ONE OF THE DOORKNOBS FROM THE KITCHEN SECURITY GATE. ____REMOVE DOUBLE KEYED DEADBOLTS ON BOTH EXIT DOORS FROM 3RD FLOOR. |
12/14/2010 | VIOL - FIRE RESIST.RATED CONST | JVINCENT | Approved | 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. ____REPAIR DRYWALL IN BASEMENT. CEILING. ____COVER HOLE IN DRYWALL CEILING. 1ST FLOOR BEDROOM HALL. |
12/14/2010 | VIOL - FIRE PROTECTION SYSTEMS | JVINCENT | Approved | 906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ____SERVICE AND TAG EXPIRED OR DISCHARGED EXTINGUISHERS. |
12/14/2010 | INSP - LIFE SAFETY | JVINCENT | Approved | NEW KITCHEN FIRE SUPPRESSION SYSTEM. FINALED 04/23/10. NEW FIRE SPRINKLER SYSTEM. FINALED 08/03/09. |
12/14/2010 | INSP - FULL | JVINCENT | Approved | FULL ANNUAL FIRE INSPECTION. |