Case: T10FR02392
Case Details
Entered Date:
11/12/2010
Applicant:
WRIGHT MIRIAM E REVOCABLE TR
Description:
Full Inspection conducted 11/8/10 I have received a copy of this report and understand the corrections needed: ______________ Business Rep.: __________________, Phone: 745-3904 Inspector: _________________, David Greenleaf, MA 23 If you have any questions please call 791-4502. Approved: ________ Re-inspection: __/__/__ (or after) Certificate of Occupancy: ON FILE, A-3, OL=156 Partial-coverage sprinkler system (kitchen only, NO FDC) Hood tagged 10/10, by Kazal Deficiency Report T10FR02325 Please correct the following Tucson Fire Code violations:
Outstanding Inspections
Case Number: T10FR02392
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/08/2010 | INSP - FULL | dgreenl1 | Violation | _____ Exit Sign Illumination - Front door (repair or replace) - ____ ____ Banquet Room Exit Signs (x2) _____ Repair Emergency Light - Banquet Room - _____ BR Hall - _____ Kitchen _____ check and repair all others as necessary _____ _____ Clean grease accumulation on fryers and hoses TFC 1008.1.8.4 - Bolt locks. Manually operated flush bolts or surface bolts are not permitted. _____ Remove hasp locking device from kitchen exit door TFC 605.6 - Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. _____ Replace filters to protect exposed wiring in Icemaker _____ Replace knock-outs in electrical panel _____ Replace cover and conduit for electrical wiring penetrating hood back-splash and seal. TFC 605.4.2 - Power supply. Relocatable power taps shall be directly connected to a permanently installed receptacle. _____ Plug office power strip directly into wall outlet. TFC 605.7 - Appliances. Electrical appliances and fixtures shall be tested and listed in published reports of inspected electrical equipment by an approved agency and installed and maintained in accordance with all instructions included as part of such listing. _____ Power cord servicing timer under hood shall be replaced by licenced electrician so as to maintain it's listing. Provde a recipt so such repair. |
Completed Inspections
Case Status: COMPLETE
Case Number: T10FR02392
Case Description: INSPECTION
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/09/2011 | INSP - REINSPECTION | dgreenl1 | Approved | noted violations have been corrected Hood system still needs cleaning and semi-annual inspection... items covered in T10FR02325 |