Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

07/09/2010

Applicant:

PARK MALL LLC

Description:

Full Inspection conducted 07/07/10 I have received a copy of this report and understand the corrections needed: ______________ Business Rep.: Kyre Pope, Phone: 514-9166 Inspector: _________________, David Greenleaf, MA 23 If you have any questions please call 791-4502. Approved: ________ Re-inspection: __/__/__ (or after) Certificate of Occupancy: On File with inaccuracies* *Occupancy Group: M, should be: B Please correct the following Tucson Fire Code violations:

Outstanding Inspections

Case Number: T10FR01305
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
07/07/2010 INSP - FULL dgreenl1 Violation TFC 904.11.6.4 - Extinguishing system service. Automatic fire-extinguishing systems shall be serviced at least every 6 months and after activation of the system. Inspection shall be by qualified individuals, and a certificate of inspection shall be forwarded to the fire code official upon completion. _____ Provide a copy of your most recent hood system report. system tagged __/__/__ by _____________________ TFC 107.1 - Maintenance of safeguards. Whenever or wherever any device, equipment, system, condition, arrangement, level of protection, or any other feature is required for compliance with the provisions of this code, or otherwise installed, such device, equipment, system, condition, arrangement, level of protection, or other feature shall thereafter be continuously maintained in accordance with this code and applicable referenced standards. _____ Emergency egress light - South sink area _____ Emergency egress light - outside office _____ Replace front door for deep fryer TFC - 3003.5.3 - Securing compressed gas containers... Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. _____ Small CO2 tank TFC 315.2.1 - Ceiling clearance. Storage shall be maintained… a minimum of 18 inches below sprinkler head deflectors in sprinklered areas of buildings. _____ Provide and maintain 18" clearance below sprinkler head deflectors (Freezer).

Completed Inspections

Case Status: COMPLETE
Case Number: T10FR01305
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
05/25/2011 INSP - REINSPECTION dgreenl1 Approved violations corrected