Case: T10FR01155
Case Details
Entered Date:
06/11/2010
Applicant:
BUHL PHILLIP
Description:
CODE VIOLATION
Outstanding Inspections
Case Number: T10FR01155
Case Status: COMPLETE
Case Description: COMPLAINT (RESIDENTIAL)
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/11/2010 | VIOL - FIRE PROTECTION SYSTEMS | NSPRENGE | Violation | PROBLEM #2- A FIRE EXTINGUISHER IS MISSING FROM A FIRE CABINET ON THE NORTH WALL OF THE SOUTH MOST BUILDING. THE ABOVE IS IN VIOLATION OF INTERNATION FIRE CODE REFERENCE NUMBER(S): 901.4.4Appearance of equipment. Any device that has the physical appearance of life safety or fire protection equipment but that does not perform that life safety or fire protection function, shall be prohibited. 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. CORRECTION: YOU WILL REPLACE THE EXTINGUISHER MISSING FROM THE CABINET AND CONTINUE TO MAINTAIN IT, OR YOU WILL REMOVE THE CABINET SO THERE IS NO APPEARANCE OF FIRE EQUIPMENT LEFT BEHIND. |
06/11/2010 | VIOL - MEANS OF EGRESS | NSPRENGE | Violation | PROBLEM #1- TWO EXIT GATES ARE WELDED SHUT ON THE NORTH AND SOUTH SIDE OF BUILDING, AND 1 EXIT GATE REQUIRES A KEY TO EXIT ON THE EAST SIDE OF BUILDING. THE ABOVE IS IN VIOLATION OF INTERNATION FIRE CODE REFERENCE NUMBER(S): 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. 1028.2 Reliability. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency when the areas served by such exits are occupied. Security devices affecting means of egress shall be subject to approval of the fire code official. 1024.6 Access to a public way. The exit discharge shall provide a direct and unobstructed access to a public way. 504.2 Maintenance of exterior doors and openings. Exterior doors and their function shall not be eliminated without prior approval. YOU WILL RESTORE ALL WELDED-SHUT GATES TO THEIR PREVIOUS USEABLE CAPACITY AND YOU WILL ENSURE THAT ALL EXIT GATES ARE ABLE TO BE EXITED FROM THE INSIDE WITHOUT THE USE OF A KEY OR SPECIAL KNOWLEDGE. |