Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

02/11/2010

Applicant:

BELLRICH LLC

Description:

Allied Medcor Services 2/9/10

Outstanding Inspections

Case Number: T10FR00350
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
02/11/2010 VIOL - BUILDING SVCS & SYSTEMS MPursley Correction Required 605.4.1 Power tap design Relocatable power taps shall be of the polarized or grounded type, equipped with overcurrent protection, and shall be listed in accordance with UL 1363. 605.4.2 Power supply Relocatable power taps shall be directly connected to a permanently installed receptacle. ____Remove daisy-chained multi-plug adapters. 605.5 Extension cords Extension cords and flexible cords shall not be a substitute for permanent wiring. Cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact. Extension cords shall be used only with portable appliances. _____ All extension cords shall be removed and/or replace with approved fused power strips. 605.6 Unapproved conditions Open junction boxes and open wiring splices shall be prohibited. Approved covers shall be provided for all switch and outlet covers. _____ Place approved cover(s) over the electrical outlets
02/11/2010 VIOL - HAZARDOUS MATERIALS,GEN MPursley Correction Required 2703.5 Hazard identification signs. Unless otherwise exempted by the fire code official, visible hazard identification signs as specified in NFPA 704 for the specific material contained shall be placed on stationary containers and above-ground tanks and at entrances to locations where hazardous materials are stored, dispensed, used or handled in quantities requiring a permit and at specific entrances and locations designated by the fire code official. _____Place appropriate marking 2703.1.1 Maximum allowable quantity per control area. The maximum allowable quantity per control area shall be as specified in Tables 2703.1.1(1) through 2703.1.1(4). _____Limit O2 to Maximum Allowable Quantities or build appropriately constructed containment area. 2703.7.1 Smoking. Smoking shall be prohibited and "NoSmoking" signs provided _____Place No Smoking signs in containment area
02/11/2010 VIOL - OXIDIZERS MPursley Correction Required 4003.1.2 Emergency shutoff. Compressed gas systemsconveying oxidizing gases shall be provided with approvedmanual or automatic emergency shutoff valves that can be activated at each point of use and at each source. _____Place emergency shutoff valve on filling system

Completed Inspections

Case Status: COMPLETE
Case Number: T10FR00350
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/07/2010 INSP - REINSPECTION MPursley Approved All corrections made 12/2/10