Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

01/20/2010

Applicant:

TUCSON PLACE PARTNERS LLC

Description:

Full Fire Prevention Inspection. Kristen Kellman 887-7535

Outstanding Inspections

Case Number: T10FR00120
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
01/20/2010 VIOL - FIRE PROTECTION SYSTEMS JBURGE Correction Required IFC 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. _____1. Service, tag and mount the portable fire extinguisher located in the back room. ________________________________________________ (John E. Bieg, Fire Inspector, Tucson Fire Department) I, ______________________ have received a copy of this inspection report. (Building Representative) ______________________________ (Captain) Re-inspection scheduled on or after _____/_____/_____ Call Inspector Bieg at 235-4785 or 791-4502, if you have any further questions. All noted Tucson Fire Code violations have been corrected: _____/_____/_____ ______________________ John E. Bieg
01/20/2010 VIOL - MEANS OF EGRESS JBURGE Correction Required IFC 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____1. Remove the double keyed lock from the west door in the back room. NOTE: Replace it with a thumb-turn deadbolt.
01/20/2010 VIOL - MEANS OF EGRESS JBURGE Correction Required IFC 1027.3 Exit sign illumination. Exit signs shall be internally or externally illuminated. _____1. The east EXIT sign shall be internally illuminated. _____2. The west EXIT sign shall be internally illuminated.

Completed Inspections

Case Status: COMPLETE
Case Number: T10FR00120
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
02/17/2010 INSP - FULL JBURGE Approved All noted Tucson Fire Code violations have been corrected.