Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

07/02/2010

Applicant:

SHIRLEY R COONEY

Description:

DETERIORATING/DECAYING FLOOR IN BUILDING

Case Violations

Case Number: T10DV04343
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
07/26/2010 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
07/26/2010 T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition.
07/26/2010 T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons.

Outstanding Inspections

Case Number: T10DV04343
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
12/28/2010 NPO - INT. BUILDING MAINTENANC JVALDEZ Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV04343
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/12/2010 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved THE BAR AREA WHICH IS THE FIRST FLOOR HAS DAMAGE TO THE FLOOR COVERING TO BE VINYL TILE TYPE. THERE ARE AREAS OF THE SUB FLOOR THAT IS DAMAGED. I SAW ONE PENETRATION THE DIAMETER OF 1 FOOT BY 1 FOOT FROM THE FIRST FLOOR TO THE BASEMENT. FLOOR JOISTS IN THE BASEMENT AND TERMITE TUNNELS. THE BASEMENT HAS A STAIRWELL RISE THAT EXCEEDS 7 INCHES AND THE RUN IS LESS THAN 11 INCHES. ONE FLOOR JOIST WAS NOTCHED BEYOND ONE-SIXTH OF THE DEPTH OF THE JOIST. ONE 2 X 4 STUD IS BEING USED AS A POST TO SUPPORT THE STAIRWELL BY MEANS OF USING ONE BOLT TO THE FRAMING CROSS MEMBER OF THE STAIRWELL. TWO CMU WALL WERE ERECTED PERPENDICULAR TO THE FLOOR JOIST SYSTEM. THERE ARE THREE 2 BY MEMBERS ACTING AS A BEAM IN THE CENTER OF A 20 FOOT SPAN, UNABLE TO DETERMINE IF THE CMU WALL ARE FULLY GROUTED.
12/28/2010 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved PERMIT T10BU01320 EXPIRES ON 6-14-2011 SCHEDULE FOLLOW UP INSPECTION ACCORDINGLY

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T10DV04343
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
07/23/2010 CONTACTED BY PHONE
07/27/2010 CONTACTED BY MAILING
07/23/2010 CONTACTED BY EMAIL
07/27/2010 NOTICE OF VIOLATION ISSUED
07/13/2011 VIOLATION CLOSED