Case: T10DV04343
Case Details
Entered Date:
07/02/2010
Applicant:
SHIRLEY R COONEY
Description:
DETERIORATING/DECAYING FLOOR IN BUILDING
Case Violations
Case Number: T10DV04343
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date | Code Statue |
---|---|
07/26/2010 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
07/26/2010 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
07/26/2010 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
Outstanding Inspections
Case Number: T10DV04343
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/28/2010 | NPO - INT. BUILDING MAINTENANC | JVALDEZ | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T10DV04343
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/12/2010 | INSP - INITIAL CODE ENFORCMENT | JVALDEZ | Approved | THE BAR AREA WHICH IS THE FIRST FLOOR HAS DAMAGE TO THE FLOOR COVERING TO BE VINYL TILE TYPE. THERE ARE AREAS OF THE SUB FLOOR THAT IS DAMAGED. I SAW ONE PENETRATION THE DIAMETER OF 1 FOOT BY 1 FOOT FROM THE FIRST FLOOR TO THE BASEMENT. FLOOR JOISTS IN THE BASEMENT AND TERMITE TUNNELS. THE BASEMENT HAS A STAIRWELL RISE THAT EXCEEDS 7 INCHES AND THE RUN IS LESS THAN 11 INCHES. ONE FLOOR JOIST WAS NOTCHED BEYOND ONE-SIXTH OF THE DEPTH OF THE JOIST. ONE 2 X 4 STUD IS BEING USED AS A POST TO SUPPORT THE STAIRWELL BY MEANS OF USING ONE BOLT TO THE FRAMING CROSS MEMBER OF THE STAIRWELL. TWO CMU WALL WERE ERECTED PERPENDICULAR TO THE FLOOR JOIST SYSTEM. THERE ARE THREE 2 BY MEMBERS ACTING AS A BEAM IN THE CENTER OF A 20 FOOT SPAN, UNABLE TO DETERMINE IF THE CMU WALL ARE FULLY GROUTED. |
12/28/2010 | INSP - FOLLOW UP CODE ENFORCE | JVALDEZ | Approved | PERMIT T10BU01320 EXPIRES ON 6-14-2011 SCHEDULE FOLLOW UP INSPECTION ACCORDINGLY |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T10DV04343
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
07/23/2010 | CONTACTED BY PHONE |
07/27/2010 | CONTACTED BY MAILING |
07/23/2010 | CONTACTED BY EMAIL |
07/27/2010 | NOTICE OF VIOLATION ISSUED |
07/13/2011 | VIOLATION CLOSED |