Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T10DV04343

Parcel: 117061900


Addresses:

254 E CONGRESS ST


Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T10DV04343

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
07/12/2010 INSP - INITIAL CODE ENFORCMENT Approved THE BAR AREA WHICH IS THE FIRST FLOOR HAS DAMAGE TO THE FLOOR COVERING TO BE VINYL TILE TYPE. THERE ARE AREAS OF THE SUB FLOOR
THAT IS DAMAGED. I SAW ONE PENETRATION THE DIAMETER OF 1 FOOT BY 1 FOOT FROM THE FIRST FLOOR TO THE BASEMENT.

FLOOR JOISTS IN THE BASEMENT AND TERMITE TUNNELS.

THE BASEMENT HAS A STAIRWELL RISE THAT EXCEEDS 7 INCHES AND THE RUN IS LESS THAN 11 INCHES.

ONE FLOOR JOIST WAS NOTCHED BEYOND ONE-SIXTH OF THE DEPTH OF THE JOIST. ONE 2 X 4 STUD IS BEING USED AS A POST TO SUPPORT THE STAIRWELL BY MEANS OF USING ONE BOLT TO THE FRAMING CROSS MEMBER OF THE STAIRWELL.

TWO CMU WALL WERE ERECTED PERPENDICULAR TO THE FLOOR JOIST SYSTEM. THERE ARE THREE 2 BY MEMBERS ACTING AS A BEAM IN THE CENTER OF A 20 FOOT SPAN, UNABLE TO DETERMINE IF THE CMU WALL ARE FULLY GROUTED.