Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

03/11/2010

Applicant:

FRANK G & FLORENCE COTTA CP/RS

Description:

Exterior complaints: Stairwell to the second story is not safe. Wooden support railing is rotting at the base. Stairs are loose and wood is soft. Paint chipping off over 50% of the exterior of the complex. Inside Unit 25 Water damage in the bathroom has never been repaired. The floor under the toilet is peeling up and mold is growing under the floor. Back patio floor and railing is soft and loose. Railing is attached by wire ties. Tenant has already fallen on the outside patio due to wood damage. Appliances are very old and not reliable. Bathroom sink has been plugged up for months. Calls to have the sink fixed have gone unanswered.

Case Violations

Case Number: T10DV01253
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 4
Violation Date Code Statue
05/10/2010 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.
05/10/2010 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (3) The building, structure or any portion thereof has been damaged by fire, earthquake, wind, flood or any other cause, to such an extent that the structural strength or stability thereof is materially less than it was before the damage and is less than the minimum requirements of the building code for new buildings of similar structure, purpose or location.
05/10/2010 T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition.
05/10/2010 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T10DV01253
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
03/26/2010 NPO(PL)-PLUMBING SYSTEM & FX JHURD Item closed
07/21/2010 NPO(EL)-WIRING/SWITCH/OUTLT/FX JHURD Follow-up inspection
07/21/2010 NPO - EXT. BUILDING MAINTENANC JHURD Follow-up inspection
07/21/2010 NPO - INT. BUILDING MAINTENANC JHURD Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV01253
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/26/2010 INSP - INITIAL CODE ENFORCMENT JHURD Approved VISITED SITE, MET W/OCCUPANT. SHOWED ISSUES. 2 STORY STRUCTURE. METAL TRAYS WHICH HOLD CONCRETE FORM STEPS DETERORIATED, RUSTING THROUGH BOTTOM, CONCRETE CHIPPING, BREAKING, 1 AREA HAS SIGN DO NOT USE STEP. OPEN EXPOSED ROMEX WIRING LAYING ON TOP OF GROUND EITHER FOR EXTERIOR LIGHTING OR WIRING TO IRRIGATION SYSTEM. OPEN JUNCTION BOXES THROUGHOUT. STRUCTURAL BLOCKS HAVE BEEN REMOVED FROM STRUCTURE TO MAKE ACCESS HOLES IN STRUCTURE WALLS TO ACCESS BATHTUBS WATER SUPPLY SYSTEMS. NO SDDITIONAL SUPPORT HAS BEEN ADDED TO HOLD STRUCTURE WALLS. 2 SEPERATE PILLERS HOLDING UP 2ND FLOOR WALKWAY ARE CRACKING AND BLOWING OUT AT BOTTOM. 4" HOLES HAVE BEEN BORED THROUGH BLOCK WALL FOR DRYER VENTS. DRYER VENTS LACK REQUIRED DRYER CAP. UNIT 25 REAR BALCONY FLOOR WEAK IN AREAS, WOOD ROTTED DETERIORATED IN S/W CORNER OF BALCONY. BALCONY RAILING LOOSE DOES NOT SECURE AS REQUIRED.B HALLWAY VYNIL FLOOR RIPPED, TORN MISSING IN AREAS. HOT WATER TANK LEAKING WATER ONTO FLOOR. BATH TUB/SHOWER AREA CAULKING DETERIORATED, CRACKING ALLOWS WATER TO ENTER BEHIND AND DETERIORATE STRUCTURE. BATHROOM FLOOR VYNIL RIPPED, TORN LIFTING FROM FLOOR. BATHROOM SINK PLUGED WATER DOES NOT DRAIN. LAUNDRYROOM ELECTRICAL SERVICE BOX HAS BEEN ENCLOSED BY 2X4'S AND DRYWALL. FUSES SHOW DOUBLE LUGGING ON SOME. NETURAL DOUBLE AND TRIPLE LUGGED.
07/21/2010 INSP - FOLLOW UP CODE ENFORCE JHURD Approved VISITED SITE. 2 ISSUES REMAIN, OTHERS ABATED. TALKED WITH OWNER WENT OVER ISSUES. NEEDS MORE TIME. EXPLAINED CAN GRANT 30 DAY EXTENSION. WILL CONSIST OF A $ 75.00 REINSPECTION. FOLLOW UP INSP. 30 DAYS. 8/21/2010

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T10DV01253
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
07/07/2010 CONTACTED BY PHONE
06/02/2010 CONTACTED BY MAILING
06/02/2010 NOTICE OF VIOLATION ISSUED
05/01/2012 VIOLATION CLOSED
07/21/2010 REINSPECTION FEE - FIRST
04/07/2011 REINSP FEE - PAID IN FULL