Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL
Address:

Entered Date:

01/08/2010

Applicant:

ZEPEDA PAUL D JR & DARRELL

Description:

APARTMENT #C: ELECTRICAL OUTLETS IN WALLS ARE LOOSE AND NO LONGER HOLDING PLUGS, LEAK IN WALL EVIDENT BY DRYWALL BULGING/BOWING AT SEEMS, LEAN IN ROOF EVIDENT BY PAINT ON KITCHEN CEILING PEELING BADLY.

Case Violations

Case Number: T10DV00103
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 1
Violation Date Code Statue
01/22/2010 CONTACTED BY EMAIL

Outstanding Inspections

Case Number: T10DV00103
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
09/17/2010 NPO(EL)-WIRING/SWITCH/OUTLT/FX JVALDEZ Item closed
09/17/2010 NPO - INT. BUILDING MAINTENANC JVALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T10DV00103
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/21/2010 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved THE TENANT IS COMPLAINING OF THE 30 AMP FUSE CONSTANTLY BLOWING. THERE ARE APPLIANCES IN THE UNIT SUCH AS A COFFEE POT, MICROWAVE, PORTABLE ELECTRIC HEATER AND A WASHING MACHINE THAT DRAW A LOT OF WATTS. I DID FINE GROUNDED ADAPTER OUTLETS CONNECTED ON TOP OF THE NON GROUNDED OUTLETS. THE HOME APPEARS TO BE A TWO WIRE SYSTEM. THE STOVE, WATER HEATER AND FURNACE ARE GAS OPERATED. THERE IS AN EVAPORATED COOLER ON THE ROOF. UNIT ( C ) WAS CONDEMNED DUE TO HAZARDOUS ELECTRICAL CONDITIONS, 30 AMP FUSE TYPE DISCONNECT HAS BROKEN INTERNAL COMPONENTS THAT WONT ALLOW THE EXTERIOR HANDLE TO DISCONNECT THE POWER TO THE DWELLING. ONE OF THE KNIFE BLADE WILL NOT DISENGAGE AND IS CAUSING AN ARC IN THE DISCONNECT. ONCE THE HANDLE IS MOVE TO THE OFF POSITION AND RAISED TO THE ON POSITION NEITHER LEG ( KNIFE BLADE) MOVE. THERE IS NO MEANS TO DISCONNECT POWER FROM THE DWELLING. TEP WAS CALLED TO PULL THE METER. UNIT WAS POSTED AN ORDER TO VACATE WAS ISSUED AND SIGNED BY THE TENANT AN NOTICE OF VIOLATION FOR PERMIT REQUIRED WAS ISSUED AND SIGNED BY THE MANAGER REQUIRING A PERMIT FOR THE LACK OF ENCLOSURES TO BOTH WATER HEATERS. THE VENT SYSTEM IN NOT PROPERLY INSTALLED THE LACK OF PITCH AND THE WOOD TO VENT CONTACT.
09/17/2010 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved COMBO PERMIT T10CM00401 WAS FINAL 04/13/2010 ALL VIOLATIONS ABATED CLOSE CASE

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T10DV00103
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
01/22/2010 CONTACTED IN PERSON
01/29/2010 RED CROSS / PRIMAVERA
02/03/2010 NOTICE OF VIOLATION ISSUED
09/27/2010 VIOLATION CLOSED

Documents

File Name Document Type  
NOV.PDF DOCUMENTS VIEW
NOV2.PDF DOCUMENTS VIEW