Case: T09FR03666
Case Details
Entered Date:
11/30/2009
Applicant:
CAMELBACK CORPORATE CENTER
Description:
FULL FIRE INSPECTION. Contact: Gilbert Esterla phone 327-2841.
Completed Inspections
Case Status: COMPLETE
Case Number: T09FR03666
Case Description: INSPECTION
Total Completed Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/30/2009 | VIOL - COMPRESSED GASES | WMOTTO | Approved | 3003.5.3 Securing compressed gas containers, cylinders and tanks. Compressed gas containers, cylinders and tanks shall be secured to prevent falling caused by contact, vibration or seismic activity. ____1. SECURE CYLINDERS IN KITCHEN PROPERLY TO WALL. |
| 11/30/2009 | VIOL - FIRE PROTECTION SYSTEMS | WMOTTO | Approved | IFC 901.4.1 Required fire protection systems. Fire protection systems required by this code or the International Building Code shall be installed, repaired, operated, tested and maintained in accordance with this code. ____1. SPRINKLER SYSTEM SHALL BE SERVICED PROVIDE REPORT UPON REINSPECTION. |
| 11/30/2009 | VIOL - FIRE PROTECTION SYSTEMS | WMOTTO | Approved | IFC 906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. ____1. CLASS K EXTINGUISHER IN KITCHENT NEEDS TO BE SERVICED AND TAGED. |
| 11/30/2009 | VIOL - FIRE PROTECTION SYSTEMS | WMOTTO | Approved | IFC 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. _____1. NOZZLES NEED TO BE ADJUSTED FOR PROPER COVERAGE ON HOOD SYSTEM. _____2. NEED SIX MONTH ANUAL HOOD INSPECTION DONE. SHOW REPORT UPON REINSPECTION. |
| 11/30/2009 | VIOL - FIRE PROTECTION SYSTEMS | WMOTTO | Approved | IFC Section 904.11.7 All deep-fat fryers shall be installed with at least a 16 inch (406 mm) space between the fryer and surface flames of adjacent cooking appliances. Exception: 1. Where a steel or tempered glass baffle plate is installed at a minimum 8 inches (203 mm) in height between the fryer and surface flames of the adjacent cooking appliance, the requirement for a 16 inch space shall not apply. Where the fryer and the surface flames of the adjacent cooking appliance are at different horizontal planes, the minimum height of 8 inches (203 mm) shall be measured from the higher of the two. _____ 1. THE FRYER SHALL COMPLY WITH THE ABOVE REQUIREMENTS. |
| 11/30/2009 | VIOL - BUILDING SVCS & SYSTEMS | WMOTTO | Approved | 605.1 Abatement of electrical hazards. Identified electrical hazards shall be abated. Identified hazardous electrical conditions in permanent wiring shall be brought to the attention of the code official responsible for enforcement of the ICC Electrical Code. Electrical wiring, devices, appliances and other equipment that is modified or damaged and constitutes an electrical shock or fire hazard shall not be used. ____1. ELECTRICAL PANNEL IN KITCHEN NEEDS TO BE REPAIRED. OPEN SLOT IN PANNEL. Re-inspection date scheduled on or after December 14th, 2009. If you have any questions or concerns please call Inspector motto at 837-7127. Thank you, _____________________________________________ William Motto, Inspector, Tucson Fire Department __________________________ - I have received a copy of this inspection report. Building Representative Re-inspection approved: ___________________________Date:__________ Captain - Tucson Fire Dept. ________________________________________ |
| 11/30/2009 | INSP - FULL | WMOTTO | Approved | Please correct tucson fire code violations. |