Case: T09DV05974
Case Details
Entered Date:
10/19/2009
Applicant:
VALDOVINOS AUDEL & BLANCA JT/RS
Description:
House fire. Emergency call out.
Outstanding Inspections
Case Number: T09DV05974
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 11
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2009 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | MROMERO | Notice of violation | |
| 10/17/2009 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | MROMERO | Notice of violation | |
| 10/17/2009 | NPO(PL)-PLUMBING SYSTEM & FX | MROMERO | Notice of violation | |
| 10/17/2009 | NPO(PL)-GAS SUPPLY/CONNECT | MROMERO | Notice of violation | |
| 10/17/2009 | NPO(PL)-WATER HEATERS | MROMERO | Notice of violation | |
| 10/17/2009 | NPO(HC)-COOLING | MROMERO | Notice of violation | |
| 10/17/2009 | NPO(HC)-HEATING & VENTILATION | MROMERO | Notice of violation | |
| 10/17/2009 | NPO - SMOKE ALARMS | MROMERO | Notice of violation | |
| 10/17/2009 | NPO - EXT. BUILDING MAINTENANC | MROMERO | Notice of violation | |
| 10/17/2009 | NPO - WORK WITHOUT PERMIT | MROMERO | Notice of violation | |
| 10/17/2009 | NPO - INT. BUILDING MAINTENANC | MROMERO | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T09DV05974
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/17/2009 | INSP - INITIAL CODE ENFORCMENT | MROMERO | Approved | Responded to house fire. Property condemmed and posted. NOV given and signed by home owner. Red Cross was on site. Single family residence. Fire started in rear laundry room possibly at electrical outlet. Shed was built within 2' of east property line. Hot wter heater in laundry room without proper enclosure and locking return core and venting. Rear bedroom located west of laundry room built without permit. Evidnet by stud over 2' on entry. No insulation in ceiling. Owner also states friends built addition and added elecrical. Electrical service is 60 amp fuse type with added subpanel with multiple brakers added without permit. Remax wiring wound together under eves to the J Box feeding into laundry and bedroom all without permits. TEP puilled meter and cut at pole due to hazardous and unsafe modifications. Southwest Gas pinned meter. |
| 08/02/2010 | INSP - FOLLOW UP CODE ENFORCE | GGOODMAN | Approved | visited site, found interior walls stripped down to the framing exposing all plumbing and electrical, and the front carport area concrete ready to pour for carport enclosure and rear porch of house concrete ready to pour for laundry room addition. * checked permits plus, found permit has been issued to owner / builder, #T10CM00636 and does not expire until 1/29/2011. f/u insp sheduled for 1/04/2011 |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T09DV05974
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 10/19/2009 | NOTICE OF VIOLATION ISSUED |
| 01/05/2011 | VIOLATION CLOSED |