Case: T09DV02130
Case Details
Entered Date:
04/21/2009
Applicant:
CHENG HOLDINGS LP
Description:
ELECTRICAL SHORT - KITCHEN FLOOD AND WENT TO TURN OFF WATER AND GOT SHOCKED ALARM # 0924317
Outstanding Inspections
Case Number: T09DV02130
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/16/2009 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
| 06/16/2009 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Item closed | |
| 08/04/2009 | NPO(HC)-HEATING & VENTILATION | RMENDOZA | Item closed | |
| 08/04/2009 | NPO - EGRESS | RMENDOZA | Item closed | |
| 08/04/2009 | NPO - EXT. BUILDING MAINTENANC | RMENDOZA | Item closed | |
| 08/04/2009 | NPO - INT. BUILDING MAINTENANC | RMENDOZA | Item closed | |
| 12/16/2009 | NPO - WORK WITHOUT PERMIT | RMENDOZA | Follow-up inspection |
Completed Inspections
Case Status: COMPLIAN
Case Number: T09DV02130
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2009 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | ADDED LAUNDRY ROOM AND BEDROOM AT THE EAST PORTION OF THE STRUCTURE. NORTH WEST BEDROOM LACKS ADEQUATE EGRESS. ONE WINDOW DOES NOT OPEN. OTHER WINDOW IS NOT OF SUFFICIENT SIZE FOR SAFE EGRESS. IT IS UNDER 5.7 SQUARE FEET OF OPENING. UNIT LACKS AN OPERATIONAL HEATING UNIT. ELECTRICAL CIRCUIT IN THE KITCHEN DAMAGED BY WATER. EXPOSED ROMEX WIRING IN THE LAUNDRY ROOM. ADDED SUBPANELS IN THE LAUNDRY ROOM. SUBPANELS ARE NOT PROPERLY LABELED. LIGHT FIXTURE COVERS ARE MISSING THROUGHOUT THE UNIT. LIGHT SWITCH AND ELECTRICAL OUTLET COVERS ARE MISSING THROUGHOUT THE UNIT. WATER LINE UNDER THE KITCHEN SINK IS BROKEN AND LEAKING. FAUCET CONTROLS ARE REVERSED. WATER LINE UNDER THE BATHROOM SINK IS LEAKING. WATER HEATER LACKS PROPER TEMPERATURE RELIEF PRESSURE VALVE PIPE. PIPE MUST DRAIN TO THE OUTSIDE OF THE UNIT AND MUST BE OF PROPER HEIGHT. CEILING DRYWALL DAMAGE IN EAST BEDROOM CLOSET. FRONT DOOR LACKS ADEQUATE WEATHER PROTECTION. |
| 12/16/2009 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | PERMIT RESEARCH - FOUND PERMIT T09CM03272 ISSUED 12/11/09. WILL REVIEW IN 30 DAYS. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T09DV02130
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 06/22/2009 | CONTACTED BY PHONE |
| 05/07/2009 | NOTICE OF VIOLATION ISSUED |
| 03/17/2011 | VIOLATION CLOSED |
| 05/07/2009 | RESEARCH |