Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

04/21/2009

Applicant:

CHENG HOLDINGS LP

Description:

ELECTRICAL SHORT - KITCHEN FLOOD AND WENT TO TURN OFF WATER AND GOT SHOCKED ALARM # 0924317

Outstanding Inspections

Case Number: T09DV02130
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
06/16/2009 NPO(EL)-WIRING/SWITCH/OUTLT/FX RMENDOZA Item closed
06/16/2009 NPO(PL)-PLUMBING SYSTEM & FX RMENDOZA Item closed
08/04/2009 NPO(HC)-HEATING & VENTILATION RMENDOZA Item closed
08/04/2009 NPO - EGRESS RMENDOZA Item closed
08/04/2009 NPO - EXT. BUILDING MAINTENANC RMENDOZA Item closed
08/04/2009 NPO - INT. BUILDING MAINTENANC RMENDOZA Item closed
12/16/2009 NPO - WORK WITHOUT PERMIT RMENDOZA Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T09DV02130
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/21/2009 INSP - INITIAL CODE ENFORCMENT RMENDOZA Approved ADDED LAUNDRY ROOM AND BEDROOM AT THE EAST PORTION OF THE STRUCTURE. NORTH WEST BEDROOM LACKS ADEQUATE EGRESS. ONE WINDOW DOES NOT OPEN. OTHER WINDOW IS NOT OF SUFFICIENT SIZE FOR SAFE EGRESS. IT IS UNDER 5.7 SQUARE FEET OF OPENING. UNIT LACKS AN OPERATIONAL HEATING UNIT. ELECTRICAL CIRCUIT IN THE KITCHEN DAMAGED BY WATER. EXPOSED ROMEX WIRING IN THE LAUNDRY ROOM. ADDED SUBPANELS IN THE LAUNDRY ROOM. SUBPANELS ARE NOT PROPERLY LABELED. LIGHT FIXTURE COVERS ARE MISSING THROUGHOUT THE UNIT. LIGHT SWITCH AND ELECTRICAL OUTLET COVERS ARE MISSING THROUGHOUT THE UNIT. WATER LINE UNDER THE KITCHEN SINK IS BROKEN AND LEAKING. FAUCET CONTROLS ARE REVERSED. WATER LINE UNDER THE BATHROOM SINK IS LEAKING. WATER HEATER LACKS PROPER TEMPERATURE RELIEF PRESSURE VALVE PIPE. PIPE MUST DRAIN TO THE OUTSIDE OF THE UNIT AND MUST BE OF PROPER HEIGHT. CEILING DRYWALL DAMAGE IN EAST BEDROOM CLOSET. FRONT DOOR LACKS ADEQUATE WEATHER PROTECTION.
12/16/2009 INSP - FOLLOW UP CODE ENFORCE RMENDOZA Approved PERMIT RESEARCH - FOUND PERMIT T09CM03272 ISSUED 12/11/09. WILL REVIEW IN 30 DAYS.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T09DV02130
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
06/22/2009 CONTACTED BY PHONE
05/07/2009 NOTICE OF VIOLATION ISSUED
03/17/2011 VIOLATION CLOSED
05/07/2009 RESEARCH

Documents

File Name Document Type  
NOV_5.7.09.DOC DOCUMENTS VIEW