Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T09DV02130
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/21/2009 | INSP - INITIAL CODE ENFORCMENT | Approved | ADDED LAUNDRY ROOM AND BEDROOM AT THE EAST PORTION OF THE STRUCTURE. NORTH WEST BEDROOM LACKS ADEQUATE EGRESS. ONE WINDOW DOES NOT OPEN. OTHER WINDOW IS NOT OF SUFFICIENT SIZE FOR SAFE EGRESS. IT IS UNDER 5.7 SQUARE FEET OF OPENING. UNIT LACKS AN OPERATIONAL HEATING UNIT. ELECTRICAL CIRCUIT IN THE KITCHEN DAMAGED BY WATER. EXPOSED ROMEX WIRING IN THE LAUNDRY ROOM. ADDED SUBPANELS IN THE LAUNDRY ROOM. SUBPANELS ARE NOT PROPERLY LABELED. LIGHT FIXTURE COVERS ARE MISSING THROUGHOUT THE UNIT. LIGHT SWITCH AND ELECTRICAL OUTLET COVERS ARE MISSING THROUGHOUT THE UNIT. WATER LINE UNDER THE KITCHEN SINK IS BROKEN AND LEAKING. FAUCET CONTROLS ARE REVERSED. WATER LINE UNDER THE BATHROOM SINK IS LEAKING. WATER HEATER LACKS PROPER TEMPERATURE RELIEF PRESSURE VALVE PIPE. PIPE MUST DRAIN TO THE OUTSIDE OF THE UNIT AND MUST BE OF PROPER HEIGHT. CEILING DRYWALL DAMAGE IN EAST BEDROOM CLOSET. FRONT DOOR LACKS ADEQUATE WEATHER PROTECTION. |