Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

01/20/2009

Applicant:

BERNAL LYDIA G

Description:

ELECTRICAL VIOLATIONS

Outstanding Inspections

Case Number: T09DV00208
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
03/06/2009 NPO(EL)-MAIN/PANEL/SUB/DISCONT JVALDEZ Item closed
03/06/2009 NPO(EL)-WIRING/SWITCH/OUTLT/FX JVALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T09DV00208
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/17/2009 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved MAIN SERVICE PANEL HAS BE TAMPERED WITH, 3 CIRCUITS BREAKERS HAVE BEEN DOUBLE LUGGED. 3 FEEDERS TO RECEPTACLE BOXES EXTERIOR OF MAIN DISCONNECT ARE PROVIDING POWER TO OTHER RECEPTACLE BOXES AND ONE 220 AMP COMPRESSOR WHICH IS HARD WIRED TO THE UNIT. THE INTERIOR OF THE DWELLING HAS RECEPTACLES IN BOTH BEDROOMS AND BATH ROOMS THAT ARE INOPERABLE, SAME WITH LIGHTS IN THESE AREAS. THE KITCHEN AND LIVING ROOM ARE OPERABLE. THE JUNCTION BOX UNDER PORCH AREA HAS CONDUCTORS DISCONNECTED WHICH LEAD INTO THE INTERIOR OF THE DWELLING. EXTENSION CORDS WERE FOUND IN THE INTERIOR AND EXTERIOR OF THE PROPERTY. ACTION TAKEN WAS THE 3 RECEPTACLE BOXES UNDER THE DISCONNECT HAD THE EXTENSION CORD REMOVED AND THE 3 CIRCUIT BREAKERS WERE SHUT OFF. THE OWNER WAS PRESENT AT THE DISCONNECT AND WAS GIVEN AN NOTICE OF VIOLATION TO HAVE THE EXPOSED, DISCONNECT WIRING UNDER THE PORCH CORRECTED. THE ORDER ALSO STATED TO REMOVE THE ADDED CONNECTIONS (THE DOUBLE LUGGING REMOVED.) ALL WORK MUST BE PERMITTED AND DONE BY A LICENSED CONTRACTOR WITHIN 10 DAYS. JUNCTION BOX UNDER PROCH AREA HAS CONDUCTORS DISCONNECTED INTERIOR OF DWELLI
03/06/2009 INSP - FOLLOW UP CODE ENFORCE JVALDEZ Approved ON SITE INSPECTION, ALL RECEPTACLES ARE OPERATING. ALL VIOLATIONS ABATED, CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T09DV00208
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
01/21/2009 CONTACTED BY PHONE
01/21/2009 NOTICE OF VIOLATION ISSUED
03/10/2009 VIOLATION CLOSED
07/21/2010 CALLBACK

Documents

File Name Document Type  
T09DV00208.PDF DOCUMENTS VIEW