Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

11/25/2008

Applicant:

SMITH FAMILY REAL ESTATE INVESTORS LTD

Description:

UST

Completed Inspections

Case Status: COMPLETE
Case Number: T08FR04427
Case Description: INSPECTION
Total Completed Inspections - 7
End Date Description Inspector Results Comments
11/25/2008 VIOL - MOTOR FUEL DISPENSING CFUNKE Approved
11/25/2008 INSP - FULL CFUNKE Approved
11/25/2008 INSP - UST CFUNKE Approved Refer to T08FR04441. Incorrect address for this inspection. This is not 7980 E speedway's report
11/25/2008 INSP - UST CFUNKE Approved 3404.2.7.10 Leak reporting. A consistent or accidental loss of liquid, or other indication of a leak from a tank system, shall be reported immediately to the fire department, the fire code official and other authorities having jurisdiction. The sumps are clean and in good condition. 2204.2 Attended self-service motor fuel-dispensing facilities. Attended self-service motor fuel-dispensing facilities shall have at least one qualified attendant on duty while the facility is open for business. The attendant's primary function shall be to supervise, observe and control the dispensing of fuel. The attendant shall control sources of ignition, give immediate attention to accidental spills or releases, and be prepared to use fire extinguishers. 2701.3.3.15 Emergency plan. A written emergency plan shall be developed to ensure that proper actions are taken in the event of an emergency, and the plan shall be followed if an emergency condition occurs. The process of developing and updating the plan shall involve the participation of affected employees. · The spill kit is in place and the employee's are familiar with the policy.
11/25/2008 VIOL - MOTOR FUEL DISPENSING CFUNKE Approved 2205.2 Equipment maintenance and inspection. Motor fuel-dispensing facility equipment shall be maintained in proper working order at all times. · Hoses on pumps 1,2,5 and 6 are cracked.
11/25/2008 INSP - UST CFUNKE Approved Section 3404.2.12.3 Existing tanks and piping. Existing underground storage tanks and piping shall be tested for leakage at the owner's or operator's expense at least every 24 months in accordance with this section. EXCEPTION: Underground storage tank systems with an approved method of detecting leaks from any component of the system. Tanks shall be emptied of flammable or combustible liquids if required tests are not completed within the specified time. When testing is required, owners or operators shall provide the fire code official with data setting forth the method of testing that is to be used and shall submit the name of a qualified individual who will conduct the test. A testing permit shall be obtained. The method of testing to be used shall consider the effects of temperature, pressure and other variables and shall establish conclusively whether the tank or piping is leaking. Pneumatic testing is prohibited. Devices used for final testing shall be capable of detecting leaks as small as 0.05 gallon per hour. Leaking piping and equipment shall not be used until repaired or replaced. The fire code official is authorized to require that the test be conducted in the code official's presence. · Please provide a copy of either the tank tightness and line leak test results or if a automatic tank gauge system is used please provide the annual calibration test report for that device and- the print out showing that the system has passed its leak test.
11/25/2008 INSP - FULL CFUNKE Approved 2205.5 Fire extinguishers. Approved portable fire extinguishers complying with Section 906 with a minimum rating of 2-A:20-B:C shall be provided and located such that an extinguisher is not more than 75 feet (22 860 mm) from pumps, dispensers or storage tank fill-pipe openings. · The fire extinguishers shall be inspected annually.