Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

11/03/2008

Applicant:

BUILDER S FASHION SQUARE LLC

Description:

Night Insp

Outstanding Inspections

Case Number: T08FR04133
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
11/03/2008 VIOL - INT.FINISH, DEC. MATL'S GDAURIA Violation TFC 803.5.1 Textile wall coverings. Textile wall coverings shall comply with one of the following: 1. The coverings shall have a Class A flame spread index in accordance with ASTM E 84 Provide documentation that the black draperies hanging @ rear of bldg are of approved materials Drapery materials @ ceiling are blocking the fire sprinkler coverage and must be removed prior to the business opening on Friday November 7, 2008. Failure to do so may result in a Citation being issued, possible closure and a probable fine.
11/03/2008 VIOL - INT.FINISH, DEC. MATL'S GDAURIA Violation TFC 807.1.2 Combustible decorative materials. The permissible amount of decorative materials meeting the flame propagation performance criteria of NFPA 701 shall not exceed 10 percent of the aggregate area of walls and ceilings. TFC 803.5.1 Textile wall coverings. Textile wall coverings shall comply with one of the following: 1. The coverings shall have a Class A flame spread index in accordance with ASTM E 84 *To qualify for the 10% coverage, approved documentation must be provided
11/03/2008 VIOL - FIRE PROTECTION SYSTEMS GDAURIA Violation TFC 903.3.3 Obstructed locations. Automatic sprinklers shall be installed with due regard to obstructions that will delay activation or obstruct the water distribution pattern. * Drapery materials @ ceiling are blocking the fire sprinkler coverage.
11/03/2008 VIOL - MEANS OF EGRESS GDAURIA Violation TFC 1014 - All exit pathways to be completely cleared so as not to impeed egress TFC 1008 Locks and latches Verify that the lock on the VIP door is openable from the inside w/out a key or any "special" knowledge

Completed Inspections

Case Status: COMPLETE
Case Number: T08FR04133
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
11/10/2008 INSP - NIGHT GDAURIA Approved