Case: T08FR00796
Case Details
Entered Date:
03/26/2008
Applicant:
HOM HOWARD & JANET LIVING TR
Description:
Full Inspection MOON SMOKE SHOP Building Rep: James Ball Phone # 622-7261 120 W. Grant Rd
Outstanding Inspections
Case Number: T08FR00796
Case Status: COMPLETE
Case Description: INSPECTION
Total Outstanding Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/26/2008 | INSP - FULL | JLONGO | Correction Required | Full inspection completed. Please correct the following Tucson Fire Cide Violations |
03/26/2008 | VIOL - FIRE PROTECTION SYSTEMS | JLONGO | Correction Required | 901.6 Inspection, testing and maintenance. Fire detection, alarm and extinguishing systems shall be maintained in an operative condition at all times, and shall be replaced or repaired where defective. -- ---Nonrequired fire protection systems and equipment shall be inspected, tested and maintained or removed. All Portable Fire Exstinguishers shall be tested once anually ____ Service or remove all Portable Fire Exstinguishers |
03/26/2008 | VIOL - MEANS OF EGRESS | JLONGO | Correction Required | 1008.1.8.5 Unlatching. The unlatching of any door or leaf shall not require more than one operation. 1008.1.8 Door operations. Except as specifically permitted by this section egress doors shall be readily openable from the egress side without the use of a key or special knowledge or effort. _____ Remove all self made brackets from rear egress door 1011.4 Internally illuminated exit signs. Internally illuminated exit signs shall be listed and labeled and shall be installed in accordance with the manufacturer's instructions and Section 2702 of the International Building Code. Exit signs shall be illuminated at all times. ____ Fix all exit signs ________________________________________________ (Joseph P. Longo, Inspector, Tucson Fire Department) I, ______________________ have received a copy of this inspection report. (Building Representative) ______________________________ (Captain) Full inspection done by Inspector Joseph P. Longo Re-inspection scheduled on or after __4_/_8__/_08__ Call Inspector Longo at 235-4262 or 791-4502, if you have any further questions. Thank you. Re-inspection passed: ______________________ Joseph P. Longo |