Outstanding Inspections

Case Number: T08DV09343
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 8
End Date Description Inspector Results Comments
12/02/2008 NPO(EL)-MAIN/PANEL/SUB/DISCONT CBIGMAN Notice of violation
12/02/2008 NPO(EL)-WIRING/SWITCH/OUTLT/FX CBIGMAN Notice of violation
12/02/2008 NPO(HC)-COOLING CBIGMAN Notice of violation
12/02/2008 NPO(HC)-HEATING & VENTILATION CBIGMAN Notice of violation
12/02/2008 NPO(DL)-DILAPIDATED STRUCTURE CBIGMAN Notice of violation
12/02/2008 NPO - EXT. HAZ/ATTRACT NUISANC CBIGMAN Notice of violation
12/02/2008 NPO - EXT. BUILDING MAINTENANC CBIGMAN Notice of violation
12/02/2008 NPO - WORK WITHOUT PERMIT CBIGMAN Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T08DV09343
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/26/2008 INSP - INITIAL CODE ENFORCMENT CBIGMAN Approved Evaporative cooler on south side of home has illegally spliced electrical conductors connecting it to extensions cords used in lieu of permanent wiring; conductors lack weather protection. Cooler has been added without permit and must connected to an approved electrical circuit. Propane tank is not secure. Appliance (cooler) stand lacks protection against the elements; requires paint. Electrical circuit on NE corner of home added without permit; lacks protection and required conduit. Electrical (6) receptacle adapter used on same circuit on NE corner of home in lieu of permanent outlet; not rated for outdoor; added without permit. Outlet must be GFCI rated. Interior light fixture on NE connected to extension cord in lieu of permanent wirin; lacks weather protection. Fixture must be rated for outdoor use and connected to an approved and permitted electrical circuit. Addition of electrical circuit for landscape lighting is not of an approved type and lacks installation into required conduit. Outdoor propane furnace heating appliance has been installed without permit. Furnace lacks proper enclosure; flue pipe does not vent to outside; existing installation of fiberglass lined spiral flex piping is not of an approved type for current application. Flex piping is not supported and properly stretched to be straight (is bent). Stairways leading from required exits are missing or not in compliance with the code. Exterior stairway(s)are not positively anchored to the mobile home. This is required per international residential code section r311.2.1
04/07/2009 INSP - FOLLOW UP CODE ENFORCE CBIGMAN Approved FINAL ITEMS ADDRESSES AND ABATED. CLOSE CASE

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T08DV09343
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
12/02/2008 CONTACTED BY MAILING
12/02/2008 NOTICE OF VIOLATION ISSUED
04/08/2009 VIOLATION CLOSED