Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

12/12/2007

Applicant:

BOYCE ANN M 30% & AJDAR VENTUR LLC 17.5% & BOYCE

Description:

inspection

Completed Inspections

Case Status: COMPLETE
Case Number: T07FR02526
Case Description: INSPECTION
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/12/2007 INSP - FULL TSISTERM Approved November 26, 2007 NORTH OF THE RIVER INVESTMENTS LLC 420 TRUXTUN AVE BAKERSFIELD CA 93301 -5316 Dear Sir or Madam, On 11-26-07, a fire prevention inspection was conducted at 4100 E. 29th St. (Las Casitas Apartments). On 12-12-07, a fire prevention re-inspection was conducted at 4100 E. 29th St. (Las Casitas Apartments). The following Tucson Fire Code Violations were noted: 1). The swimming pool is empty and in disrepair. This is a nuisance and shall be remedied. 2). In the pool equipment room there is an electrical box missing a cover. This is a violation of IFC 605.6: 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Please install approved covers on all electrical boxes. 3). In the storage closet near the reception area there is a large hole in the ceiling. This is a violation of IFC 703.1: 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Please cover the hole in the ceiling. 4). At your facility there are many fire extinguishers that have not received the proper maintenance. This is a violation of IFC 906.2: 906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Please maintain or remove your fire extinguishers. 5). In units 11207, 11212, 14204, 13212, 13211, 13219, 15210, 4207, 3204, 4211, 4208, 7104, and 9204 there are broken or missing windows. This is a violation of IFC 311.2: 311.2 Safeguarding vacant premises. Temporarily unoccupied buildings, structures, premises or portions thereof shall be secured and protected in accordance with this section. Please replace glass and secure all premises. 6). The south storage building is missing windows, wall panels, and skylights. This is a violation of IFC 311.2: 311.2 Safeguarding vacant premises. Temporarily unoccupied buildings, structures, premises or portions thereof shall be secured and protected in accordance with this section. Please secure this building. 7). In the south storage facility there is a missing cover at the electrical panel and electrical boxes missing their covers. This is a violation of IFC 605.6: 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Please install approved covers on all electrical boxes. This letter is to inform you that abatement of these Tucson Fire Code violations must be completed by 1-3-07 . A re-inspection shall be conducted at that time to ensure compliance. If you have questions, or if I may be of any assistance please call me at 791-4501 extension 130. Thank you. Sincerely, Tom Sisterman Fire Inspector Tucson Fire Department TS cc:file
12/12/2007 INSP - FULL TSISTERM Approved November 26, 2007 NORTH OF THE RIVER INVESTMENTS LLC 420 TRUXTUN AVE BAKERSFIELD CA 93301 -5316 Dear Sir or Madam, On 11-26-07, a fire prevention inspection was conducted at 4100 E. 29th St. (Las Casitas Apartments). The following Tucson Fire Code Violations were noted: 1). The swimming pool is empty and in disrepair. This is a nuisance and shall be remedied. 2). In the pool equipment room there is an excessive amount of trash. This is a violation of IFC 304.1, 304.2: 304.1 Waste accumulation prohibited. Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. 304.2 Storage. Storage of combustible rubbish shall not produce conditions that will create a nuisance or a hazard to the public health, safety or welfare. Please remove trash from this area. 3). In the pool equipment room there is an electrical box missing a cover. This is a violation of IFC 605.6: 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Please install approved covers on all electrical boxes. 4). In the manager's office there are 3 electrical boxes missing covers. This is a violation of IFC 605.6: 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Please install approved covers on all electrical boxes. 5). In the storage closet near the reception area there is a missing junction box cover plate. This is a violation of IFC 605.6: 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Please install approved covers on all electrical boxes. 6). In the storage closet near the reception area there is a large hole in the ceiling. This is a violation of IFC 703.1: 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Please cover the hole in the ceiling. 7). In the storage closet near the reception area there is an excessive amount of trash. This is a violation of IFC 304.1, 304.2: 304.1 Waste accumulation prohibited. Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. 304.2 Storage. Storage of combustible rubbish shall not produce conditions that will create a nuisance or a hazard to the public health, safety or welfare. Please remove trash from this area. 8). In the laundry room there is a large hole in the wall. This is a violation of IFC 703.1: 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. Openings through fire-resistance-rated assemblies shall be protected by self- or automatic-closing doors of approved construction meeting the fire protection requirements for the assembly. Please cover hole in the wall with approved fire rated material. 9). In the laundry room behind the dryers there is an excessive amount of trash and lint. This is a violation of IFC 304.1, 304.2: 304.1 Waste accumulation prohibited. Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. 304.2 Storage. Storage of combustible rubbish shall not produce conditions that will create a nuisance or a hazard to the public health, safety or welfare. Please remove trash and lint from this area. 10). In the laundry room there are 2 electrical boxes missing their covers. This is a violation of IFC 605.6: 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Please install approved covers on all electrical boxes. 11). The barbecue near the laundry room is too close to the tree. This is a violation of IFC 307.6.2.2: 307.6.2.2 Location. Barbecue pits outside of buildings shall not be located within 10 feet (3048 mm) of combustible walls or roofs or other combustible material. Please relocate barbecue to a suitable location. 12). At your facility there are many fire extinguishers that have not received the proper maintenance. This is a violation of IFC 906.2: 906.2 General requirements. Portable fire extinguishers shall be selected, installed and maintained in accordance with this section and NFPA 10. Please maintain or remove your fire extinguishers. 13). Near the east dumpsters there is an excessive amount of furniture and trash. This is a violation of IFC 304.1, 304.2: 304.1 Waste accumulation prohibited. Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. 304.2 Storage. Storage of combustible rubbish shall not produce conditions that will create a nuisance or a hazard to the public health, safety or welfare. Please remove furniture and trash from this area. 14). In units 11207, 11212, 14204, 13212, 13211, 13219, 15210, 4207, 3204, 4211, 4208, 7104, and 9204 there are broken or missing windows. This is a violation of IFC 311.2: 311.2 Safeguarding vacant premises. Temporarily unoccupied buildings, structures, premises or portions thereof shall be secured and protected in accordance with this section. Please replace glass and secure all premises. 15). Units 9203, 5207, and 1208 have barbecue grills on their balconies. This is a violation of IFC 308.3.1: 308.3.1 Open-flame cooking devices. Charcoal burners and other open-flame cooking devices shall not be operated on combustible balconies or within 10 feet (3048 mm) of combustible construction. Please remove all barbecues from balconies. 16). Units 8203 and 4103 have an excessive amount of furniture and trash on the patio. This is a violation of IFC 304.1, 304.2: 304.1 Waste accumulation prohibited. Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. 304.2 Storage. Storage of combustible rubbish shall not produce conditions that will create a nuisance or a hazard to the public health, safety or welfare. Please remove furniture and trash from this area. 17). The south storage building is missing windows, wall panels, and skylights. This is a violation of IFC 311.2: 311.2 Safeguarding vacant premises. Temporarily unoccupied buildings, structures, premises or portions thereof shall be secured and protected in accordance with this section. Please secure this building. 18). In the south storage facility there is a missing cover at the electrical panel and electrical boxes missing their covers. This is a violation of IFC 605.6: 605.6 Unapproved conditions. Open junction boxes and open-wiring splices shall be prohibited. Approved covers shall be provided for all switch and electrical outlet boxes. Please install approved covers on all electrical boxes. 19). The south storage building has excessive amounts of furniture and trash inside and outside of the building. This is a violation of IFC 304.1, 304.2: 304.1 Waste accumulation prohibited. Combustible waste material creating a fire hazard shall not be allowed to accumulate in buildings or structures or upon premises. 304.2 Storage. Storage of combustible rubbish shall not produce conditions that will create a nuisance or a hazard to the public health, safety or welfare. Please remove furniture and trash from this area. This letter is to inform you that abatement of these Tucson Fire Code violations must be completed by 12-12-07 . A re-inspection shall be conducted at that time to ensure compliance. If you have questions, or if I may be of any assistance please call me at 791-4502 extension 130. Thank you. Sincerely, Tom Sisterman Fire Inspector Tucson Fire Department TS cc:file