Case Details

Status:

COMPLETE

Type:

INSPECTION

Entered Date:

12/12/2007

Applicant:

RITA & HOUGHTON LLC

Description:

General Inspection

Completed Inspections

Case Status: COMPLETE
Case Number: T07FR02524
Case Description: INSPECTION
Total Completed Inspections - 1
End Date Description Inspector Results Comments
12/26/2007 INSP - FULL JBEZEL Approved Upon reinspection on 12/26/07 problem #1 and #2 were corrected. The following additional peoblems were noted: ___4.PROBLEM: Ceiling tiles missing above center freezer. TFC REFERENCE: 703.1 Maintenance. The required fire-resistance rating of fire-resistance-rated construction (including walls, firestops, shaft enclosures, partitions, smoke barriers, floors, fire-resistive coatings and sprayed fire-resistant materials applied to structural members and fire-resistant joint systems) shall be maintained. Such elements shall be properly repaired, restored or replaced when damaged, altered, breached or penetrated. Openings made therein for the passage of pipes, electrical conduit, wires, ducts, air transfer openings and holes made for any reason shall be protected with approved methods capable of resisting the passage of smoke and fire. REQUIRED CORRECTION: Replace missing ceiling tiles above freezer. ___5. PROBLEM: Fire extingusher behind front counter on floor TFC RFERENCE:906.7 Hangers and brackets. Hand-held portable fire extinguishers, not housed in cabinets, shall be installed on the hangers or brackets supplied. Hangers or brackets shall be securely anchored to the mounting surface in accordance with the manufacturer’s installation instructions. REQUIRED CORRECTION: Mount fire extinguishers on bracket in clearly visible location. Also see references in problem #3. ___6. PROBLEM: Rear exit partially blocked with portable shelving unit. Aisle clearance is inadequate. TFC REFERENCE: 1003.6 Means of egress continuity. The path of egress travel along a means of egress shall not be interrupted by any building element other than a means of egress component as specified in this chapter. Obstructions shall not be placed in the required width of a means of egress except projections permitted by this chapter. The required capacity of a means of egress system shall not be diminished along the path of egress travel. AND: 1021.2 Width. The width of exit passageways shall be determined as specified in Section 1005.1 but such width shall not be less than 44 inches (1118 mm), except that exit passageways serving an occupant load of less than 50 shall not be less than 36 inches (914 mm) in width. REQUIRED CORRECTION: Provide clear pathway of at least 36 inches in width to the exit for staff to exit in the event of an emergency. These violations must be corrected in 2 weeks. This is a reinspection. If violations are not corrected upon next reinspection the citation process will be initiated. Property Representative Signature: _________________________. Fire Inspector Signature: _________________________(791-4502). Reinspection Date: ___/___/___ or later. __X_Approved ___Not Approved