Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T07FR01169
Case Details
Entered Date:
06/19/2007
Applicant:
SAXON WILLIAM R
Description:
full inspection
Completed Inspections
Case Status: COMPLETE
Case Number: T07FR01169
Case Description: INSPECTION
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/19/2007 | INSP - FULL | JDAVIS | Approved | abated |
06/19/2007 | INSP - FULL | JDAVIS | Approved | FIRE INSPECTION REPORT 6/4/2007 Walgreens ATTN: Patty Mayer 9184 E Valencia Tucson, AZ. 85747 Mrs. Mayer The Tucson Fire Department has conducted a fire safety inspection at the above stated business on June 4, 2007. Below is a list of violations that shall be corrected to provide compliance with the applicable codes, regulations and ordinances. Compliance is required by the 2003 International Fire Code (with modifications). A Re-inspection will be performed on or about June 18, 2007 Notice of Violations: HAZARDOUS COMMUNICATIONS _____ 407.2 Material Safety Data Sheets. Material Safety Data Sheets (MSDS) for all hazardous materials shall be readily available on the premises. _____ 407.4 Training. Persons responsible for the operation of areas in which hazardous materials are stored, dispensed, handled or used shall be familiar with the chemical nature of the materials and the appropriate mitigating actions necessary in the event of a fire, leak or spill. · Train employees on the location of the MSDS/ Hazardous Communication Program. ELECTRICAL _____ 315.2.3 Equipment rooms. Combustible material shall not be stored in boiler rooms, mechanical rooms or electrical equipment rooms. _____ 605.3 Working space and clearance. A working space of not less than 30 inches (762 mm) in width, 36 inches (914 mm) in depth and 78 inches (1981 mm) in height shall be provided in front of electrical service equipment. Where the electrical service equipment is wider than 30 inches (762 mm), the working space shall not be less than the width of the equipment. No storage of any materials shall be located within the designated working space. _____ 605.5 Extension Cords. Extension cords and flexible cords shall not be a substitute for permanent wiring. Extension cords and flexible cords shall not be affixed to structures, extended through walls, ceilings or floors, or under doors or floor coverings, nor shall such cords be subject to environmental damage or physical impact… · Cosmetics _____ 3003.3 Security. Compressed gas containers, cylinders, tanks and systems shall be secured against accidental dislodgment and against access by unauthorized personnel in accordance with Sections 3003.3.1 through 3003.3.3. · Stock Room _____ 1027.2 Reliability. Required exit accesses, exits or exit discharges shall be continuously maintained free from obstructions or impediments to full instant use in the case of fire or other emergency. Security devices affecting means of egress shall be subject to approval of the fire code official. · SW Exit · Stock room exit _____ 901.4.1 Required fire protection systems. Fire protection systems required by this code or the International Building Code shall be installed, repaired, operated, tested and maintained in accordance with this code. · Keep riser clear of stock The Tucson Fire Department is committed to the protection of your property. Your help as a business owner and as a citizen is greatly appreciated. __________________________________________________ Property owner or Property Representative Signature _________________________________ Abatement Date __________________________ Captain Signature Sincerely, Jimmy R. Davis, Jr Fire Inspector Tucson Fire Department |