Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

04/25/2007

Applicant:

WALKER GREGORY MARSHALL & YOSHIKO JT/RS

Description:

TPD REFERRAL - FAMILY IS LIVING IN HOUSE WITH NO POWER//WAITING FOR RESPONSE CALLED IN BY INSPECTOR VIDAL//GAVE 45 MINUTE ETA

Completed Inspections

Case Status: COMPLIAN
Case Number: T07DV03723
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/25/2007 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved THESE NOTES ALSO IN SIRE. RECEIVED A CALL FOR EMERGENCY CALLOUT REGARDING THAT OF ELECTRICAL SERVICE BY USE OF EXTENSION CORDS. STRUCTURE HAS NO ELECTRICAL SERVICE AROUND 4:15PM. INSP ARRIVED ON SITE AROUND 5:00PM. MET WITH TPD OFFICER S HOYTE. OFFICER INDICATED THAT RESIDENCE OF UNIT 3 WAS USING ELECTRICAL EXTENSION CORD TO POWER HIS UNIT FROM UNIT 2. OFFICER ALSO STATED ELECTRICAL SERVICE HAS BEEN TURNED OFF BY TEP. PRIOR TO ARRIVING ON SITE, DNR INSPECTOR ATTEMPTED CONTACTING OWNER TO INFORM OF POSSIBLE SHUTDOWN. INSPECTOR REQUESTED OWNER MAKE CONTACT AND/OR MEET ON SITE. MADE CONTACT WITH TENANT, INFORMED HIM DNR HAD BEEN CONTACTED REGARDING UNIT WAS WITHOUT REQUIRED ELECTRICAL POWER. TENANT STATED HE HAD TEP TERMINATE SERVICE DUE TO TO TENANT WOULD BE VACATING UNIT TOMORROW 04-26-07. TENANT STATED HE HAD PERMISSION FROM OWNER TO STAY. INSPECTOR INFORMED HIM DUE TO CODE REQUIREMENT BY COT TENANT COULD NOT BE ALLOWED TO OCCUPY UNIT WITHOUT REQUIRED ELECTRICAL SERVICE. INSPECTOR REQUESTED ENTRY INTO UNIT TO ACCESS LIVING CONDITION. TENANT REFUSED, BUT AFTER SOME CONVERSATION TENANT ALLOWED ENTRY INTO UNIT. MIN HOUSING ISSUES ARE AS FOLLOWS ELECTRICAL SYS 1) 2 WIRE SYSTEM INSTALLED WITH 3 PRONG RECEPTACLES IN KITCHEN, ONE FOR FRIDGE AND OTHER ON KITCHEN WALL BY SINK HAS NO GFI 2) RECEPTACLE WERE FOUNDMISSING OVER PLATES 3) BEDROOM LIGHT FIXTURE HANGING FROM ELECTRICAL CONDUCTOR (CEILING) 4) ALL TWO PRONG RECEPTACLES ARE WORN OUT AND NO LONGER CAN HOLD IN APPLIANCE CORD PLUGS. 5) EXTERIOR DISCONNCETED PANELS ARE IN A DETERIORATING AND DELAPIDATED STATE, ELECTRICAL CONDUCTOR PENETRATING BACK SIDE OF PANELS ARE NOT PROTECTED BY RUBBER GROMETS, SHUT OFF HANDLE MECHANISMS COMING APART, CONTACT SPADE NOT MAKING FULL CONTACT. 6) EXTERIOR SUB PANEL MOUNTED UNDER ROOF OVERHANG WITHOUT PROPER WEATHER PROTECTION, ELECTRICAL CONDUCTOR UNDER EIGHT FEET NOT IN REQUIRED CONDUIT. 7) EXTERIOR MOUNTED TOGGLE SWITCH LACKS WEATHER PROTECTION COVER (RAINTIGHT) PLUMBING SYS 1) BATH TUB DRAIN CLOGGED AND WILL NOT DRAIN 2) BATH TUB OVER FLOW DRAIN COVER MISSING FIRE SAFETY 1) STRUCTURE LACKS WORKING SMOKE DETECTORS 2) SEVERAL WINDOW WERE FOUND BOLTED TOGETHER AND WILL NOT ALLOW FOR QUICK EASY EGRESS FROM STRUCTURE. COOLING SYS 1) COOLER HAS NOT BEEN MAINTAINED, CODER CONTAINS LARGE AMOUNTS OF RUST AND SOME SECTIONS RUSTED THROUGH 2) AIR DEFUSER MISSING FOR DUCT OPENING ON WALL INTERIOR FEATURES 1) INTERIOR FLOOR COVERINGS HAVE NOT BEEN MAINTAINED, SEVERAL AREAS WERE FOUND WITH BROKEN TILES THROUGHOUT UNIT. 2) INTERIOR WALLS AND DOOR CONTAIN LARGE AMOUNT OF GRAFFITI THROUGHOUT STRUCTURE EXTERIOR SURFACES 1) SEVERAL BROKEN WINDOWS THROUGHOUT STRUCTURE 2) BACK DOOR HAS NOT BEEN MAINTAINED IN GOOD CONDITION, DOOR SURFACE HAS BEEN ALLOWED TO S PLINTER AND HAS EXPOSED LAYERS OF VENEER 3) ALL EXTERIOR WOOD FASCICE IN A DELAPIDATED DETERIORATING CONDITION PAINT SURFACE HAS BEGUN TO BLISTER AND CHIP AWAY, SOME SECTION CONTAIN WOOD WROUGHT. CASE WILL REQUIRE RESEARCH, NOV TO BE ISSUED AFTER COMPLETING RESEARCH. PICTURE WERE TAKEN AND NOV WAS HANDDELIVERED FOR TC SEC 16-11 (C) ELECT SYS LACK OF REQUIRED ELECTRICAL SERVICE TC SEC 16-14 STRUCTURE CONSTITUTING A NUISANCE, STRUCTURE EXHIBITS ACTUAL DANGER. STRUCTURE WAS POSTED UNFIT TO OCCUPY AND TEP WAS NOTIFIED AND REQUESTED TO MONITOR. CASE # 070425048 TPD OFFICER S HOYTE WAS PRESENT. - Mel
11/21/2007 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved VISITED SITE FOR COMPLIANCE INSPECTION ON 11-21-07. MET WITH OWNER ON-SITE TO ACCESS ABATED VIOLATION. ALL VIOLATIONS HAVE BEEN ADDRESSED. 1) ALL NEW ELECTRICAL UPRADE AT METERS WITH EXTERIOR WIRING DONE UNDER PERMIT # T07EL01531,30,29&28. 2) ALL INTERIOR ELECTRICAL ISSUES ABATED, NEW RECEPTACLES THROUGH UNIT, NEW LIGHT FIXTURES. 3) NEW SMOKE ALARMS THROUGOUT UNITS. 4) ALL WINDOW HARDWARE OPERABLE & BOLTS USED TO SECURE WINDOWS SHUT REMOVED. 5) NEW FLOORING & CARPET THROUGOUT. 6) ALL EXTERIOR & INTERIOR GRAFFITI REMOVED & INTERIOR PAINTED. 7) NEW TUB & TILE INSTALLED IN BATHROOM, PLUMB ISSUES ABATED. 8) EXTERIOR FASCIA REPLACED & WEATHER PROTECTION PAINT COVER HAS BEEN APPLIED. PICTURES TAKEN. MARK CASE CLOSED & COMPLIANCE.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T07DV03723
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
09/25/2007 CONTACTED BY PHONE
06/11/2007 NOTICE OF VIOLATION ISSUED
09/11/2007 COURT ORDERED ABATEMENT
11/27/2007 VIOLATION CLOSED