Case: T07DV00693
Case Details
Entered Date:
01/22/2007
Applicant:
ROSE WENDELLE ANNE
Description:
PROBLEMS WITH GAS LINE. RECEIVED A $600 GAS BILL FOR A SMALL HOUSE. GAS COMPANY TOLD HER THE WRONG AMP AND COOLER DAMPER WAS WRONG. BIG HOLE WAS IN ROOF, LANDLORD SAID IT WAS FIXED. CALLER ISN'T SURE. SOUTHWEST GAS WON'T GIVER HER A BREAK ON BILL. LANDLORD SAID SHE WOULD ONLY GIVE HER $100 TOWARDS THE BILL. 2A GTI SM 01/24/07 2-5-07 - 2ND CALL//CALLER STATED HUSBAND DID NOT KNOW WHAT WAS GOING ON//PLS CALL CARISSA AT 661-5085/
Outstanding Inspections
Case Number: T07DV00693
Case Status: COURTCMP
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/14/2008 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | RMENDOZA | Item closed | |
| 08/14/2008 | NPO - EXT. BUILDING MAINTENANC | RMENDOZA | Item closed | |
| 11/25/2008 | NPO(PL)-PLUMBING SYSTEM & FX | RMENDOZA | Item closed | |
| 11/25/2008 | NPO(HC)-HEATING & VENTILATION | RMENDOZA | Item closed | |
| 11/25/2008 | NPO - WORK WITHOUT PERMIT | RMENDOZA | Court Inspection |
Completed Inspections
Case Status: COURTCMP
Case Number: T07DV00693
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/21/2007 | INSP - INITIAL CODE ENFORCMENT | RMENDOZA | Approved | SOUTH PORTION OF DWELLING CARPORT ENCLOSED AND BEING UTILIZED AS A BEDROOM. ELECTRICAL CIRCUITS ADDED. SOUTH WALL FLEXES APPROX 2-3 INCHES. HEAT PUMP INSTALLED ON THE ROOF WITHOUT PERMITS. UNIT LACKs SMOKE DETECTORS KITCHEN GFCI IS INOPERABLE AND IS TOO CLOSE TO WATER FAUCET. NORTH SIDE BEDROOM LACKS LIGHT SWITCH COVER. FRONT PORCH LIGHT LACKS GLOBE. MAIN SERVICE ELECTRICAL PANEL INSTALLED WITHOUT PERMITS. EXPOSED ROMEX EXITING TOP AND BOTTOM OF SERVICE BOX. PANEL IS NOT PROPERLY LABELED AND ADDRESSED. PANEL COVER DOES NOT FIT PROPERLY. WATER HEATER LACKS VENT PIPE. LACKS TPRV PIPE. LACKS ENCLOSURE. WASHER LOCATED IN SOUTH BEDROOM CLOSET DRAINS TO THE REAR YARD AND IS NOT CONNECTED TO AN APPROVED SEWER SYSTEM. GAS SERVICE CONNECTION HAS TWO SERVICE LINES. ONE ENTERING THE STRUCTURE AND ONE INTO THE GROUND. EVIDENCE OF ROACH INFESTATION. ROACHES EXITING ELECTRICAL PLUGS WHEN TESTING WINDOWS INOPERABLE IN THE KITCHEN, LIVING ROOM, NORTH BEDROOM, CENTER AND SOUTH BEDROOM. PHOTOS TAKEN. RM |
| 11/25/2008 | INSP - FOLLOW UP CODE ENFORCE | RMENDOZA | Approved | WATER HEATER ABATED. ROOM ADDITION BEING MADE TO PATIO. ELECTRIC REMOVED. WINDOW REMOVED. COURT HEARING HELD. PLEAD RESPONSIBLE TO CHARGE C. A & D DISMISSED, CONTINUED TO FEB. 26, 1:30 PM. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T07DV00693
Case Status: COURTCMP
Total Completed Case Activity Conditions: 6
| Date | Name |
| 02/26/2007 | CONTACTED BY MAILING |
| 03/04/2008 | CITATION ISSUED |
| 12/11/2008 | POSTING/PUBLICATION |
| 03/13/2009 | VIOLATION CLOSED |
| 05/15/2008 | COURT HEARING INFO |
| 08/20/2008 | RESEARCH |