Case: T06FR02959
Case Details
Entered Date:
12/29/2006
Applicant:
KARABELAS DIMITRI C
Description:
Full inspection
Completed Inspections
Case Status: COMPLETE
Case Number: T06FR02959
Case Description: INSPECTION
Total Completed Inspections - 13
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2006 | VIOL - MEANS OF EGRESS | DRAMIREZ | Approved | TFC 1027.2 Exits shall be continuously maintained from obstructions and impediments. Screen door to the rear exit binds against the floor when opening. |
| 04/06/2006 | VIOL - MEANS OF EGRESS | DRAMIREZ | Approved | TFC 1008.1.8.4 Manually operated flush bolts or surface bolts shall not be permitted. (rear exit door) |
| 04/06/2006 | VIOL - FIRE PROTECTION SYSTEMS | DRAMIREZ | Approved | TFC 904.11.1 Pull station for hood system shall be relocated to a location with a minimum of 10 ft. and a max. of 30 ft. travel distance from cooking appliances. Must be in the direction of the exit. |
| 04/06/2006 | VIOL - FIRE PROTECTION SYSTEMS | DRAMIREZ | Approved | TFC 3003.3 Compressed gas cylindersshall be secured against accidental dislodgement. |
| 04/06/2006 | VIOL - FIRE PROTECTION SYSTEMS | DRAMIREZ | Approved | TFC904.11.5 Portable fire extinguihsers shall be provided within 30 feet travel distance of cooking equipment. |
| 04/06/2006 | VIOL - FIRE PROTECTION SYSTEMS | DRAMIREZ | Approved | TFC 904.4 Commercial hood system shall be inspected and tested at 6 mo. intervals. Your system is past due for inspection. |
| 04/06/2006 | VIOL - FIRE PROTECTION SYSTEMS | DRAMIREZ | Approved | TFC Portable fire extinguishers shall be installed in a hanger or braket. |
| 04/06/2006 | VIOL - FIRE PROTECTION SYSTEMS | DRAMIREZ | Approved | TFC 906.6 Portable extingguishers shall not be obstructed from view. |
| 04/06/2006 | VIOL - BUILDING SVCS & SYSTEMS | DRAMIREZ | Approved | TFC 605.5 Extension cords shall not be a substitute for permanent wiring. |
| 04/06/2006 | VIOL - FIRE SERVICE FEATURES | DRAMIREZ | Approved | TFC 505.1 You shall provide address numbers for the building. Numbers shall be legible and visable from the street. |
| 04/06/2006 | VIOL - FIRE SERVICE FEATURES | DRAMIREZ | Approved | TFC 605.3 Working space and clearance shall be provided for the electric service panel. Minimum of 36 inches. |
| 04/06/2006 | VIOL - FIRE SERVICE FEATURES | DRAMIREZ | Approved | TFC 504.2 Exterior doors rendered nonfunctional and that retain a functional appearance Shall have affixed to the exterior side of the door a sign reading "THIS DOOR BLOCKED". |
| 04/06/2006 | INSP - FULL | DRAMIREZ | Approved |