Inspection

Outstanding Inspections

Case Number: T06FR02698
Case Status: FIELD
Case Description: INSPECTION
Total Outstanding Inspections - 11
End Date Description Inspector Results Comments
INSP - FULL None Not Inspected
10/26/2006 VIOL - ADMINISTRATION JLANGEJA Violation IFC 102.6- No building or structure shall be used or occupied until the building official has issued a Certificate of Occupancy.
10/26/2006 VIOL - PRECAUTION AGAINST FIRE JLANGEJA Violation IFC 315.2- Storage of combustibles shall be orderly. Trash around dumpster shall be cleaned up.
10/26/2006 VIOL - PRECAUTION AGAINST FIRE JLANGEJA Violation IFC 315.2.3- Combustible materials shall not be stored in electrical rooms. Propane cylinder shall be removed.
10/26/2006 VIOL - BUILDING SVCS & SYSTEMS JLANGEJA Violation IFC 605.1- Identified electrical hazards shall be abated. 1. light fixture in safe room shall be covered. 2. wires shall be protected below the ceiling and shall not extend through ceiling. (x 3) 3. motors over food service shall be covered. 4. motor under drink fountain shall be shielded from combustibles. 5. switch in water heater closet shall be replaced and covered. 6. cord to coffee machine shall be repaired.
10/26/2006 VIOL - BUILDING SVCS & SYSTEMS JLANGEJA Violation IFC 605.4- Multiplug adapters and unfused plug strips shall be prohibited. (N Wall)
10/26/2006 VIOL - MEANS OF EGRESS JLANGEJA Violation IFC 1003.6- The path of egress shall not be blocked. The rear exit shall be clear of obstructions. (S)
10/26/2006 VIOL - MEANS OF EGRESS JLANGEJA Violation IFC 1027.6- Where panic hardware is installed, whether required or not, panic hardware shall be the only locking devise on the door. All other hardware shall be removed.
10/26/2006 VIOL - COMPRESSED GASES JLANGEJA Violation IFC 3003.3- Compressed gas cylinders shall be secured from accidental dislodgement. (x 2)
10/26/2006 VIOL - FLAMMABLE LIQUIDS JLANGEJA Violation IFC 3403.2.12- Existing underground storage tanks and piping shall be tested for leakage at the owner's expense. 1. Tank tightness every 2 years 2. Line leak detection every year
11/14/2006 INSP - REINSPECTION JLANGEJA Correction Required Need to remove hardware from rear exit, waiting for LLD/TT from 3rd party.