Case Details

Status:

COMPLETE

Type:

INSPECTION
Address:

Entered Date:

08/16/2006

Applicant:

PORTELLO HENRIETTA

Description:

FIRE INSPECTION CHECK LIST USED

Completed Inspections

Case Status: COMPLETE
Case Number: T06FR02440
Case Description: INSPECTION
Total Completed Inspections - 11
End Date Description Inspector Results Comments
02/20/2007 VIOL - MEANS OF EGRESS MWAINWRI Approved
02/20/2007 VIOL - MEANS OF EGRESS MWAINWRI Approved 2003 IFC 1027.3 Egress pathway clear All path ways to all exits required or not. This includes exits from windows MUST HAVE PATH TO SECONDARY EXIT IN NE BEDROOM CLEAR
02/20/2007 VIOL - MEANS OF EGRESS MWAINWRI Approved 2003 IFC TFC 1008.18 Door operation No double key dead-bolt locks, no special knowledge needed, no slide bolt locks. Only one unlatching device,Except group R’s can have night latch, indicating dead bolt, or security chain on exits only REMOVE DBL KEYED DEAD BOLT FROM FRONT SCREEN DOOR. REPLACE WITH THUMB TURN TYPE LATCH.
02/20/2007 VIOL - FIRE SERVICE FEATURES MWAINWRI Approved
02/20/2007 VIOL - FIRE SERVICE FEATURES MWAINWRI Approved 2003 IFC 505.1 ADDRESSING All building will have approved address numbers plainly legible & visible from the street fronting the property. Min. 3” high w/ contrasting background. 1) REPAIR ADDRESS NUMBERS, NEED CONTRASTING COLOR BEHIND NUMBERS.
02/20/2007 VIOL - PRECAUTION AGAINST FIRE MWAINWRI Approved
02/20/2007 VIOL - BUILDING SVCS & SYSTEMS MWAINWRI Approved
02/20/2007 VIOL - BUILDING SVCS & SYSTEMS MWAINWRI Approved 2003 IFC 603.1 & 316.2 Fuel fired appliances and house cleaning. Furnaces, dryer and hot water heaters are all heat sources and must bemaintained and cleaned. NOT STORAGE IN FRONT OF HOTWATER HEATER.
02/20/2007 VIOL - BUILDING SVCS & SYSTEMS MWAINWRI Approved 2003 IFC TFC 605.5 Extension cords Grounds, used as permanent wiring, run under carpet, attached to walls can be replaced w/ power strip that has overcurrent protection 1) REMOVE EXTENSION CORD IN SW BEDROOM 2) REMOVE EXTENSION CORD ON BACK PORCH
02/20/2007 VIOL - BUILDING SVCS & SYSTEMS MWAINWRI Approved 2003 IFC 605.1 605.1 Abatement of electrical hazards Exposed electrical wires , covers, and panels locked. Undergroud romex can be above 7’ and not in conduit, if protected from UV light and damage. 1) REPAIR OUTLET AND WIRES IN STORAGE ROOM E WALL. 2) REMOVE SURGE STRIP THROUGH WALL. HARD WIRE OUTLET FOR SURGE PROTECTOR TO PLUG INTO.
02/20/2007 INSP - FULL MWAINWRI Approved