Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL ZONING

Entered Date:

12/15/2006

Applicant:

FARACI CATHERINE

Description:

STOVE GETS TOO HOT, TOO MUCH TRASH WEEDS & DEBRIS NEAR THE HOUSE, 3 FOOT BARRIER NOT PRESENT NEAR HOUSE? ELECTRICAL WATER HEATER NOT PROTECTED PROPERLY. 5 ELDERLY PERSONS OCCUPYING HOUSE.

Outstanding Inspections

Case Number: T06DV03032
Case Status: COMPLIAN
Case Description: RESIDENTIAL ZONING
Total Outstanding Inspections - 14
End Date Description Inspector Results Comments
VIOL - ILLEGAL ACCESSORY STRUC None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - ROOF None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
NPO(PL)-PLUMBING SYSTEM & FX None Not Inspected
NPO(PL)-SEWAGE DISPOSAL (SYS) None Not Inspected
VIOL(PL) - FIXTURES None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
VIOL(SA) - BATHS None Not Inspected
NPO - EGRESS None Not Inspected
NPO - SMOKE ALARMS None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T06DV03032
Case Description: RESIDENTIAL ZONING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/12/2006 INSP - INITIAL CODE ENFORCMENT RMENDOZA Approved KITCHEN - ELECTRICAL OUTLET EAST WALL SHOWS OPEN GROUND. DOOR DOES NOT SEAL PROPERLY AND HAS LARGE GAPS. WASHER AREA - LIGHT FIXTURE HAS NO GLOBE AND IS RIGHT UP AGAINST SHELVING, LESS THEN 18". VENT LINE AND DRAIN POSSIBLY INSTALLED WITHOUT PERMITS. DRYER VENT CONNECTED TO WHAT APPEARS TO BE THE ORIGINAL WATER HEATER VENT PIPE. AREA BEHIND WASHER/DRYER IS FULL OF LINT AND REQUIRES CLEANING. DINING ROOM - WINDOW CRANK INOP. DOOR DOES NOT SEAL PROPERLY AND DOOR FRAME IS DETERIORATED AND CRACKED. LIVING ROOM - DOOR DOES NOT SEAL PROPERLY. LACKS WINDOW CRANKS. ELECTRICAL OUTLET ON THE SOUTH WALL SHOWS OPEN GROUND. MANY REPAIRS TO THE CEILING DUE TO ROOF DAMAGE. HALLWAY CARPET IS UNSECURED AND POSES A TRIP HAZARD. EMERGENCY LIGHT IN HALLWAY IS INOP. BEDROOM 1 - LIGHT FIXTURE IN THE CLOSET LACKS PROPER CLEARANCE AND GLOBE. EXTENSION CORD CONNECTED TO FIXTURE TO POWER TV. LACKS WINDOW CRANK, WINDOW INOP. MAIN BATHROOM - LACKS TUB FAUCET FIXTURES. SINK MIRROR IS BROKEN, LACKS TOILET FLUSH HANDLE. BEDROOM 2 - BEDROOM AND CLOSET DOOR ARE NOT ATTACHED TO THE DOOR FRAMES. CLOSET LIGHT LACKS PROPER CLEARANCE AND GLOBE. ACCESS TO THE WINDOW IS BLOCKED BY DEBRIS. BEDROOM 3 - WINDOW CRANKS INOP. CLOSET LIGHT LACKS GLOBE AND PULL CHAIN IS INOP. BEDROOM 4 - WINDOW ACCESS BLOCK BY CLOTHES DRESSER. OUTSIDE REAR STRUCTURE - WOOD IS SEVERLY DETERIORATED AND LACKS SUFFICIENT WEATHER PROTECTION. LIGHT FIXTURE AT REAR DOOR LACKS GLOBE. MAIN ELECTRICAL SERVICE - MISSING BLANKS AND PLUGS, LACKS LABELING AND ADDRESSING. DUE TO RUST AND DETERIATION UNABLE TO PULL DEAD FRONT. WATER LINES ON THE WEST AND NORTH SIDE OF THE STRUCTURE LACK PROPER WEATHER PROTECTION. WATER HEATER LACKS COLD WATER SHUT OFF. TPRV IS NOT ACCESSIBLE. VENT PIPE IS BELOW ROOF LINE. ALSO LACKS PROPER ENCLOSURE. ADDITION OF PORCH AND CARPORT ( ONE PEICE ) ON THE NORTH AND WEST SIDE OF THE STRUCTURE IS ATTACHED. BEAM IS INSTALLED INCORRECTLY AND COVER (ROOF) HAS BEEN PARTIALLY REMOVED. FRONT PORCH IS SEPERATING FROM THE ROOF TRUSSES. APPROX 3 INCH GAP AT THE NORTH EAST CORNER. ROOF ON THE SOUTH SIDE OF THE DWELLING SHOWS SEVERE DETERIORATION. ROOF PROTECTION IS PEELED AND TRUSSES ARE BOWED AND SAGGING. RM
04/29/2008 INSP - FOLLOW UP CODE ENFORCE RMENDOZA Approved PROPERTY NO LONGE A CARE GIVER HOME. CLOSE THIS CASE. OPENING A NEW CASE AS RES. OCCUPIED WITH NEW VIOLATIONS.

Completed Activity Special Conditions

Case Description - RESIDENTIAL ZONING
Case Number - T06DV03032
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
12/27/2006 CONTACTED BY MAILING
02/22/2008 VIOLATION CLOSED