Case Details

Status:

VOID

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

12/30/2005

Applicant:

LANE SYLVIA

Description:

HOUSE HAS OLD WIRING, KEEPS SHORTING OUT.

Outstanding Inspections

Case Number: T05DV01278
Case Status: VOID
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: VOID
Case Number: T05DV01278
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/03/2006 INSP - INITIAL CODE ENFORCMENT MROMERO Approved SITE INSPECTION: TENANT CINDY AT HOME WITH TWO CHILDREN. MAIN SERVICE: DROP TO WEATHER HEAD APPEARS TO BE NOT AT PROPER HEIGHT, JUST ABOVE ROOF. 100 AMP MAIN SERVICE FUSE TYPE. WITH TWO SUB PANELS WORK WITHOUT PERMITS. HAZARDOUS MODIFICATIONS TO SERVICE PANEL, DOUBLE LUGGING ON LINE SIDE, FEEDING SUBPANEL AS NEUTRAL TRIPPLE LUGGING ON LOADSIDE FEEDING TWO SEPERATE SUBPANELS GROUND CONDUCTORS, MIXING COPPER AND ALUMINUM. ALSO DOUBLE LUGGING TO GROUND WITH SUB PANEL. BOX IS WEATHERED AND WATER DAMAGED, RUSTING IN INTERIOR. SUBPANEL 1ST, LIVE/HOT CONDUCTOR NO FUSES IN PANEL LOAD SIDE CONDUCTORS MELTING, NOT SURE WHERE THEY FEAD CONNECTION/ SCREW HOLD IN WIRE BARELY HOLDING WIRES. NO DEDICATED NUETRAL SECOND SUB PANEL, FRIED WIRE, WEATHERED. DOUBLE LUGGING ON LOADSIDE. MISSING FUSES, NO GROUNDING DEDICATED NUETRALS MISSING ROCK OUTS DISCONNECT FRIED, NOT ABLE TO SAFELY DISCONNECT POWER INTERIOR SUB PANEL; GROUND AND NEUTRAL BEING COMBINED. MIXING ALUMINUM WITH COPPER SPLICING INSIDE OF SUBPANEL. BUSS BAR APPEARS TO BE LOOSE. CARPORT SHED LIGHT BEING FED BY UNPROTECTED ROMEX CARPORT LIGHT; HAZARDOUS UNPROTECTED ROMEX FEEDING LIGHT OUTSIDE OUTLET NOT GFI PROTECTED. ETST SHOWS OPEN GROUND CONDUCT IS LOOSE NOT PROPERLY SECURED TO WALL. INTERIOR: LIVING ROOM: BROKEN LIGHT SWITCH; SMOKE DETECTOR MISSING BATTERY NOT ABLE TO TEST. OUTLETS ARE MIXED FROM 2 PRONG TO 3 PRONG OUTLESTS A/C WALLMOUNT NOT HARDWIRED TENANT STATES IT DROPS REST OF HOME. KITCHEN: OUTLETS TEST OF CABINET UNDER SINK OFF HINGES PLUMBING: DRAIN LEAKING STOVE: ELECTRIC BURNS RIGHT REAR NOT WORKING: HAZARDOUS ELECTRIC UNDER STOVE LOOTED PANTRY MISSING DOOR. WAS EXTERIOR LAUNDRYROOM: ADDED TO ORIGINAL DWELLING OPEN GROUNDS THROUGHOUT LAUNDRY ROOM 1 COMPUTER ROOM WEST WALL OUTLET NOT WORKING OTHERS SHOW OPEN GROUND 2 KIDS ROOM: OPEN GROUND OTHERS THAT DO NOT WORK 3 ROOM SPARE 2 PRONG OUTLETS HALLWAY BATHROOM, WENT NOT WORKING PROPERLY HEATER AND HOT WATER HEATER HWH DOES NOT HAVE PROPER PRESSURE RELIEF VALVE, WATER SPICKET. HEATER; DIRTY NEEDS CLEANING, SERVICING, HEATER DOESN'T WORK MASTER BEDROOM HAS NO GROUNDED OUTLETS TENANT DAVID STATES HAS NO GROUNDED OUTLETS PORCH: ROTTED WOOD, POST NOT ANCHORED.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV01278
Case Status: VOID
Total Completed Case Activity Conditions: 1
Date Name
02/15/2006 CONTACTED BY PHONE