Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

11/29/2005

Applicant:

BRIAN EDWARD (NEW OWER)

Description:

HAS BEEN 3 DAYS THAT ENTIRE BUILDING HAS NO HEAT. 12/1 UPDATE: NO ELECTRICITY SINCE FRIDAY OF LAST WEEK.

Outstanding Inspections

Case Number: T05DV01153
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 20
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - ATTACHED STRUCTURES None Not Inspected
VIOL(BL) - ROOF None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
VIOL(PL)-OTHER None Not Inspected
NPO(HC)-HEATING & VENTILATION None Not Inspected
NPO(DL)-VACANT & UNSEC.STRUCT None Not Inspected
VIOL(DL)-NUISANCE STRUCTURE(H) None Not Inspected
VIOL(SA) - BATHS None Not Inspected
VIOL(SA) - KITCHEN None Not Inspected
NPO - EGRESS None Not Inspected
NPO - SMOKE ALARMS None Not Inspected
12/08/2005 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 12/8/05, ELECTRICAL: VISITED SITE, TOOK PICTURES, INSP. ORTA ASST. 1ST STRUCTURE: SOUTH/EAST CORNER, MANAGER LIVES IN FRONT SECTION. BACK SECTION HOUSES A LAUNDRY ROOM FOR HOUSE KEEPING, INSIDE LAUNDRY ROOM, SHOWS EVIDENCE OF ADDED ELECTRICAL CIRCUITS, CONDUIT, CONVENIENCE OUTLETS, JUNCTION BOXES INSTALLED AFTER ORIGINAL CONSTRUCTION, WATER LINES ADDED AFTER ORIGINAL CONSTRUCTION. BEHIND DRYERS LARGE ACCUMULATION OF DUST AND LINT. CEILING SHOWS EVIDENCE OF ROOF LEAK DUE TO WATER DETERIORATION TO DRYWALL. HOT WATER TANK ROOM DOOR OFF HINGES. HOT WATER TANK HAS BEEN REPLACED FROM ORIGINAL. EXTERIOR ROOF EAVES SHOW DETERIORATION DUE TO LACK OF PROTECTIVE COVERING. OPEN RAMADA WHICH HOUSES SODA MACHINES HAS BEEN ADDED, 2X4'S OVER SPANNED IN LENGHT AND IN WIDTH, 2X4 SPANS APPOX. 12' IN LENGHT AND SPANS APPOX. 4' IN WIDTH. ATTCHED TO MAIN STRUCTURE. NORTH WALL TO EAST UNIT 152 OPEN JUNCTION BOX ENERGIZED CONDUCTORS. CONDUIT NOT PROPERLY SUPPORTED. ELECTRICAL CONNECTIONS BY A/C UNIT OPEN AND EXPOSED, ENERGIZED. FAR SOUTH/EAST WALL SEVERAL ELECTRICAL BOXES, MAIN DISCONNECT, SUB-PANELS, TRIPLED LUGGED. TOP BOX WIRES CUT, ARE ENERGIZED. THESE WIRES ARE THE ONES THAT DOUBLE LUG IN LOWER BOX. 4TH BOX FROM LEFT TO RIGHT, LACKS NETURAL, HAS 6 DISCONNECTS ON ONE DROP, 5 BY CODE. 5TH BOX CIRCUIT PANEL LACKS MAIN DISCONNECT, GROUND WIRE LOOSE FROM STRUCTURE NOT PROPERLY SECURED. DISCONNECTS NOT PROPERLY LABELED AS TO WHAT THEY SERVE. MISSING FRONT DEAD PLATE. MAIN GROUND ELECTRODE CONDUCTOR ENCLOSER NOT EFFECTIVELY BONDED DUE TO IMPAIRED K/O'S. IMPAIRED GROUND AT BOTH ENDS. OPEN ELECTRICAL SPLICES AT LIGHT FIXTURES. USE OF WRONG ELECTRICAL WIRING TO LIGHT. BLD. 2: BACK EAST SIDE ELECTRICAL CONDUIT NOT PROPERLY SUPPORTED. A/C WALL UNITS HAS BEEN INSTALLED, WOOD FRAMING DETERIORATED, MISSING IN AREAS, OPENINGS NOT PRPERLY SEALED. JUNCTION BOX TO SMALL FOR AS MANY WIRES ENTERING, CONDUIT NOT SECURED TO JUNCTION BOX, CONDUIT NOT SECURED TO STRUCTURE. JUNCTION BOX FALLING FROM WALL NOT PROPERLY SECURED. OVER HANG HAS HOLE FROM WHERE ADDED CIRCUITS AND CONDUIT HAS BEEN ADDED. MAIN DISCONNECT 1ST BOX, MISSING FRONT DEAD PLATE. 2ND BOX. BACK FEEDING SEVERAL BRANCH CIRCUITS. 30 AMP BREAKER-12 GAUGE WIRE SHOWS WHERE OVER HEATING AND MELTING OUTER COATING. MISSING FRONT DEAD PLATE. DOUBLE LUGGING ON GROUNDING BAR. GROUND WIRES IN JUNCTION NOT PROPERLY CAPPED. MIXING OF BREAKERS IN PANEL BOX. 3RD BOX. WIRE CONNECTIONS LOOSE. MISSING FRONT DEAD PLATE. MIXING OF BREAKERS IN PANEL BOX. 4TH BOX. ENCLOSER FOR MAIN GROUNDING ELECTRODE CONDUCTOR IS CROOKED CAUSING KNOCK OUT RINGS TO SEPERATE AND FURTHER CAUSING AN IMPEDANCE TO THE BONDING CONTINUITY. INTERIOR BUSSING WEATHERING, BREAKERS RUSTED, OPERATION IMPAIRED, BUSS BAR SCREWS RUSTED, WIRE COATING DETERIORATED, CRACKING, PEELING, BOX IS FALLING FROM WALL. CONDUIT NOT PROPERLY SECURED TO JUNCTION BOXES. ADDED ELECTRICAL CIRCUITS. APPEARS TO BE USING SINGLE POLE BREAKERS FOR 220 VOLTS. BLD. 3: HOT WATER TANK ROOM: FLUE PIPE NOT PROPERLY INSTALLED. HOT WATER TANK LACKS P.R.V. DRAIN LINE. ON BOTH TANKS. WATER LINES HAS BEEN INSTALLED. INSTALLED A HOLE IN L/B CONDULET FITTING USING CONDULET FITTING AS JUNCTION BOX, USE OF WRONG MATERIAL. 3 SEPERATE MAINS: 1ST BOX: NOT BONDED TO ENCLOSER. 2ND BOX: MAIN BREAKER PANEL BOARD NETURAL BAR NOT BONDED TO ENCLOSER. DOUBLE LUGGED ON BREAKER. 12 GAUGE WIRE INSTALLED ON 50 AMP BREAKER. CUT WIRES IN BOX, ENERGIZED THROUGH INDUCTANCE. (REMOVE) MISSING FRONT DEAD PLATE. 3RD BOX: USING WHITE WIRE AS HOT, NEEDS TO BE IDENIFIED. NETURAL BAR NOT GROUNDED. ELECTRODE GROUNDING CONDUCTOR NOT VISIBLE. (CHECK) BLD. 4: BLD. FEEDER COMMING FROM BLD 3 NOT PROPERLY SECURED AT ROOF TOP. CONDUIT NOT PROPERLY SECURED. CONNECTIONS TO BOXES NOT PROPERLY SECURED. ROOF TOP HAS SEVERAL AREAS WHERE CONDUIT HAS SEPERATED AND CUT IN WIRE CAUSING SPARKS WHEN MOVED. CONVENIENCE OUTLET DANGLING. ROOF TOP ON BLD HAS SEVERAL ISSUES TO BE ADDRESSED. ROMEX IN CONDUIT THEN CHANGES TO PLASTIC SEPERATING AT CONNECTIONS. OFFICE FRONT: BLD 4 USE OF WRONG WIRING FOR ALL EXTERIOR LIGHTING USING ZIP WIRE. OPEN SPLICES, OPEN CONNECTIONS. GTO CABLE NOT PROPERLY INSTALLED, NO DOUBLE BACKS BETWEEN NEON TUBING. HAZARDOUSLY INSTALLED. BEHIND OFFICE STILL BLD 4: ELECTRICAL ROOM: 4 SEPERATE BOXES: A, B1, B2, C BOX A: BACK FEEDING OF DISCONNECTED WIRES THROUGH IN BOX, OPEN ENDS. DOUBLE LUGGING OF BREAKERS. LOOSE CONDUCTOR CONNECTIONS. ARCING. MIXTURE OF BREAKERS, NOT COMPATABLE. ADDED ELECTRICAL CIRCUITS AND PANEL BOX. PANEL BOX HAS BEEN GROUNDED. WRONG. MISSING FRONT DEAD PLATE FILLER PLATES. LACKS PROPER LABELING. BOX B-1: BACK FEEDING DISCONNECTED LINES THROUGH INDUCTANCE. BUSS BAR SHOWS EVIDENCE OF CHARING. LACKS PROPER LABING. CONDUIT SEPERATED FROM PANEL BOX. MISSING FRONT DEAD PLATE FILL PLUGS. BOX B-2: BACKING FEEDING DISCONNECTED LINES. BOX HAS SEVERAL DISCONNECTED LINES ON INTERIOR. MISMATCHED BREAKERS. LACKS PROPER LABELING. CUT WIRE STRANDS ON FEEDER TO MAKE FIT, IMPROPER. FRONT DEAD PLATE MISSING FILLER BLANK COVERS. BOX C: SUB-PANEL HAS BEEN BONDED, WRONG. COMPLETE ROOM HAS ADDED ELECTRICAL CIRCUITS. EXTERIOR LIGHTING: OPEN SPLICES THROUGHOUT PROPERTY, USE OF WRONG MATERIAL, USING EXTENSION CORD WIRING TO SUPPLY ELECTRICAL POWER. ALSO CONDUICT OR PVC PIPING DOES TO CONNECT TO FIXTURES ALLOWING FOR EXPOSED WIRING, CONDUIT OR PVC PIPEING SEPERATING AT CONNECTION JOINTS. BLD.:4: ROOF TOP, MANY ISSUES. CONDUIT NOT PROPERLY SECURED, HAS BREAKS, SEPERATION, WHEN CONDUIT IS MOVED SPARKS DUE TO INSULATION BROKEN, CUT. ELECTRICAL DROP CONNECTION THAT GOES TO SIGN HAS BARE METAL CONNECTIONS. ALL ROOF TOP ELECTRICAL NEEDS TO BE REEVALUATED BY LICENSED CONTRACTOR. BLD 5: PANEL BOX DOUBLED LUGGED ON 7 SEPERATE BREAKERS. LACKS FRONT DEAD PLATE. EXPOSED WIRING DETERIORATING DUE EXPOSED TO SUN LIGHT.MISMATCHED BREAKERS. UNSUPPORTED CONDUIT. ENERGIZED OPEN BOXES. OPEN CONVENIENCE OUTLETS. 220 VOLTS INSTALLED WITH AN 110 VOLT RECEPTACLE. EAST SIDE OF BLD 5 HOT WATER TANKS REPLACED FROM ORIGINAL. WATER LINES ADDED, REPLACED FROM ORIGINAL. NOT PROPERLY INSTALLED. HOT WATER TANKS SITTING ON BRICKS WITH WOOD ON TOP. ROOF TOP SHOWS CRACKS DETERIORATION. INTERIOR ROOM SHOWS EVEDIENCE OF ROOF LEAK DUE TO WATER DETERIORATION. BLD 6: ROOF TOP : SEVERAL OPEN ENERGIZED JUNCTION BOXES. NORTH END OPEN AND EXPOSED ROMEX. ADDED ELECTRICAL CIRCUITS. BLD 7: ELECTRICAL SYSTEM: EXPOSED ROMEX. KNOCK OUTS MISSING. CONDUIT SEPERATED FROM BOXES. ADDED ELECTRICAL CIRCUITS. CONDUIT BROKEN IN 3 SEPERATE AREAS EXPOSING ROMEX. ZIP CORD BEING USED TO SUPPY PWER TO EXTERIOR LIGHTING. 3 SEPERATE PANEL BOXES. LACKS PROPER CLEARENCES. NEW PANEL BOX INSTALLED RATED FOR 125 AMPS INSTALLED WITH 200 AMP SERVICE.
12/13/2005 INSP - FOLLOW UP CODE ENFORCE JHURD Correction Required 12/10/05, RECIEVED CALL FROM MIKE MAINT. MAN WHO STATED THAT HE IS ON SITE WITH ELECTRICAL CONTRACTOR AND WOULD LIKE ME TO MEET WITH BOTH OF THEM TO GO OVER ISSUES ON EMERGENCY REPAIRS THAT WILL BE REQUIRED, AGREED TO MEET. VISITED SITE, WENT OVER ISSUES WITH ELECTRICAL CONTRACTOR (RON WILKOWSKI) FROM WILKOWSKI ELECTRIC, ASKED RON IF HE HAD ALL READY GONE THROUGH PROPERTY TO SEE CONDITION HE DID, ITS A MESS HE STATED, WENT OVER MAIN ISSUES THAT WAS DEEMED IMMEDIATE AND HAZARDOUS THAT WOULD REQUIRE IMMEDIATE ATTENTION, GAVE RON A COPY OF THE NOTICE AND ORDER STATING SUCH, RON STATED THAT HE SHOULD NOT HAVE A PROBLEM REACHING THE THURSDAY 12/15/05 DEAD LINE, IF HIRED, MIKE MAINT MAN STATED THAT HE WOULD HAVE THE JOB. WILL BE SENDING THE OWNER A PROPOSAL. ALSO GAVE MIKE THE MAINT. MAN A COPY OF SAME NOTICE AND ORDER HE DID SIGN N/O STATES WILL BE DONE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV01153
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
Date Name
11/29/2005 CONTACTED BY PHONE
05/26/2006 CONTACTED IN PERSON
12/14/2005 NOTICE OF VIOLATION ISSUED
05/25/2006 POSTING/PUBLICATION
10/30/2006 VIOLATION CLOSED
05/26/2006 COURT HEARING INFO
01/31/2006 CONTACTED BY MAILING
02/09/2006 ELECTRICAL CONTRACTOR:

Documents

File Name Document Type  
NOV-NPO-DNR(A0003314).PDF DOCUMENTS VIEW
NOV-NPO-DNR(A0003314).DOC 2.PDF DOCUMENTS VIEW
NOV-NPO-DNR(A0003314)2.PDF DOCUMENTS VIEW
2006-02-09 012.JPG IMAGES VIEW
2006-02-09 013.JPG IMAGES VIEW
2006-02-09 014.JPG IMAGES VIEW
2006-02-09 015.JPG IMAGES VIEW
2006-02-09 016.JPG IMAGES VIEW
2006-02-09 018.JPG IMAGES VIEW
2006-02-09 019.JPG IMAGES VIEW
2006-02-09 020.JPG IMAGES VIEW
2006-02-09 021.JPG IMAGES VIEW
2006-02-09 022.JPG IMAGES VIEW
2006-02-09 023.JPG IMAGES VIEW
2006-02-09 024.JPG IMAGES VIEW
2006-02-09 025.JPG IMAGES VIEW
2006-02-09 026.JPG IMAGES VIEW
2006-02-09 027.JPG IMAGES VIEW
2006-02-09 028.JPG IMAGES VIEW
2006-02-09 029.JPG IMAGES VIEW
2006-02-09 030.JPG IMAGES VIEW
2006-02-09 031.JPG IMAGES VIEW
2006-02-09 032.JPG IMAGES VIEW
2006-02-09 033.JPG IMAGES VIEW
2006-02-09 034.JPG IMAGES VIEW
2006-02-09 035.JPG IMAGES VIEW
2006-02-09 036.JPG IMAGES VIEW
2006-02-09 037.JPG IMAGES VIEW
2006-02-09 038.JPG IMAGES VIEW
2006-02-09 039.JPG IMAGES VIEW
2006-02-09 040.JPG IMAGES VIEW
2006-02-09 041.JPG IMAGES VIEW
2006-02-09 042.JPG IMAGES VIEW
2006-02-09 043.JPG IMAGES VIEW
2006-02-09 044.JPG IMAGES VIEW
2006-02-09 045.JPG IMAGES VIEW
2006-02-09 047.JPG IMAGES VIEW
2006-02-09 048.JPG IMAGES VIEW
2006-02-09 049.JPG IMAGES VIEW
2006-03-09 027.JPG IMAGES VIEW
2006-03-09 028.JPG IMAGES VIEW
2006-03-09 029.JPG IMAGES VIEW
2006-03-09 030.JPG IMAGES VIEW
2006-02-09 012.JPG IMAGES VIEW
2006-02-09 013.JPG IMAGES VIEW
2006-02-09 014.JPG IMAGES VIEW
2006-02-09 015.JPG IMAGES VIEW
2006-02-09 016.JPG IMAGES VIEW
2006-02-09 018.JPG IMAGES VIEW
2006-02-09 019.JPG IMAGES VIEW
2006-02-09 020.JPG IMAGES VIEW
2006-02-09 021.JPG IMAGES VIEW
2006-02-09 022.JPG IMAGES VIEW
2006-02-09 023.JPG IMAGES VIEW
2006-02-09 024.JPG IMAGES VIEW
2006-02-09 025.JPG IMAGES VIEW
2006-02-09 026.JPG IMAGES VIEW
2006-02-09 027.JPG IMAGES VIEW
2006-02-09 028.JPG IMAGES VIEW
2006-02-09 029.JPG IMAGES VIEW
2006-02-09 030.JPG IMAGES VIEW
2006-02-09 031.JPG IMAGES VIEW
2006-02-09 032.JPG IMAGES VIEW
2006-02-09 033.JPG IMAGES VIEW
2006-02-09 034.JPG IMAGES VIEW
2006-02-09 035.JPG IMAGES VIEW
2006-02-09 036.JPG IMAGES VIEW
2006-02-09 037.JPG IMAGES VIEW
2006-02-09 038.JPG IMAGES VIEW
2006-02-09 039.JPG IMAGES VIEW
2006-02-09 040.JPG IMAGES VIEW
2006-02-09 041.JPG IMAGES VIEW
2006-02-09 042.JPG IMAGES VIEW
2006-02-09 043.JPG IMAGES VIEW
2006-02-09 044.JPG IMAGES VIEW
2006-02-09 045.JPG IMAGES VIEW
2006-02-09 047.JPG IMAGES VIEW
2006-02-09 048.JPG IMAGES VIEW
2006-02-09 049.JPG IMAGES VIEW
2006-05-22 001 SOME OF THE GROUNDING ON BLDG. NO. IMAGES VIEW
2006-05-22 002 GROUNDING AND WATER BOND. .JPG IMAGES VIEW
2006-05-22 003 FACIA- NOT COMPLETED. .JPG IMAGES VIEW
2006-05-22 004 NEW PANELBOARD. .JPG IMAGES VIEW
2006-05-22 005 FACIA AND ROOF SYSTEM. .JPG IMAGES VIEW
2006-05-22 006 OVERALL VIEW OF THE FACIA. .JPG IMAGES VIEW
2006-05-22 007 BOARD-UP ON BUILDING NO. 4. .JPG IMAGES VIEW
2006-05-22 008 GAP IN WOOD SEAL NOT ABATED. .JPG IMAGES VIEW
2006-05-22 009 UNPROTECTED WOOD .JPG IMAGES VIEW
2006-05-22 010 RAW SEWAGE NOT TAKEN CARE OF .JPG IMAGES VIEW
2006-05-22 011 SEAL AROUND A-C LACKING. .JPG IMAGES VIEW
2006-05-22 012 WORK ON WATER AND VENT SYSTEM O.K. IMAGES VIEW
2006-05-22 013 NEW VENTING .JPG IMAGES VIEW
2006-05-22 014 NOT ALL OF PORCH NOT TORN DOWN..JPG IMAGES VIEW
2006-05-22 015 FACIA WORK AT PORCH. .JPG IMAGES VIEW
2006-05-22 016 CLEARANCES IMPROVED AT ELECTRIC ROO IMAGES VIEW
2006-05-22 017 OVERALL VIEW POSTING STILL IN PLACE IMAGES VIEW
1742 N ORACLE RD 10 13 06 10.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 11.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 12.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 13.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 14.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 15.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115309.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115310.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115311.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115312.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115313.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115314.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115315.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115316.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115317.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115318.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115319.JPG IMAGES VIEW
1742 N ORACLE RD 10 13 06 T05DV0115320.JPG IMAGES VIEW