Inspection History Details
Inspection Status: Correction Required
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T05DV01153
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Correction Required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/16/2006 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 10/13/06, VISITED SITE, TOOK PICTURES, MET WITH MAINT. SUPER. ON SITE, ALL TILES, DETERIORATED WOOD, ROOF EAVES HAS BEEN ADDRESSED. CLOSE CASE. COMPLIANCE. | |
09/07/2006 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 9/7/06, VISITED SITE, TOOK PICTURES, MET WITH PROPERTY SUPERVISIOR ROBERT, WENT OVER ISSUES, NOT ALL OF WEATHER PROTECTION HAS BEEN COMPLETED AT THIS TIME, ALL UNITS HAS BEEN VACATED FOR REMODEL, INTERIORS, DRYWALL, PAINT, ETC. DID SEE WHERE SOME PLUMBING HAS BEEN REPLACED, COPPER PIPES, BATHROOM SUPPLY LINES, PERMIT REQUIRD. RESEARCH | |
12/08/2005 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 12/8/05, ELECTRICAL: VISITED SITE, TOOK PICTURES, INSP. ORTA ASST. 1ST STRUCTURE: SOUTH/EAST CORNER, MANAGER LIVES IN FRONT SECTION. BACK SECTION HOUSES A LAUNDRY ROOM FOR HOUSE KEEPING, INSIDE LAUNDRY ROOM, SHOWS EVIDENCE OF ADDED ELECTRICAL CIRCUITS, CONDUIT, CONVENIENCE OUTLETS, JUNCTION BOXES INSTALLED AFTER ORIGINAL CONSTRUCTION, WATER LINES ADDED AFTER ORIGINAL CONSTRUCTION. BEHIND DRYERS LARGE ACCUMULATION OF DUST AND LINT. CEILING SHOWS EVIDENCE OF ROOF LEAK DUE TO WATER DETERIORATION TO DRYWALL. HOT WATER TANK ROOM DOOR OFF HINGES. HOT WATER TANK HAS BEEN REPLACED FROM ORIGINAL. EXTERIOR ROOF EAVES SHOW DETERIORATION DUE TO LACK OF PROTECTIVE COVERING. OPEN RAMADA WHICH HOUSES SODA MACHINES HAS BEEN ADDED, 2X4'S OVER SPANNED IN LENGHT AND IN WIDTH, 2X4 SPANS APPOX. 12' IN LENGHT AND SPANS APPOX. 4' IN WIDTH. ATTCHED TO MAIN STRUCTURE. NORTH WALL TO EAST UNIT 152 OPEN JUNCTION BOX ENERGIZED CONDUCTORS. CONDUIT NOT PROPERLY SUPPORTED. ELECTRICAL CONNECTIONS BY A/C UNIT OPEN AND EXPOSED, ENERGIZED. FAR SOUTH/EAST WALL SEVERAL ELECTRICAL BOXES, MAIN DISCONNECT, SUB-PANELS, TRIPLED LUGGED. TOP BOX WIRES CUT, ARE ENERGIZED. THESE WIRES ARE THE ONES THAT DOUBLE LUG IN LOWER BOX. 4TH BOX FROM LEFT TO RIGHT, LACKS NETURAL, HAS 6 DISCONNECTS ON ONE DROP, 5 BY CODE. 5TH BOX CIRCUIT PANEL LACKS MAIN DISCONNECT, GROUND WIRE LOOSE FROM STRUCTURE NOT PROPERLY SECURED. DISCONNECTS NOT PROPERLY LABELED AS TO WHAT THEY SERVE. MISSING FRONT DEAD PLATE. MAIN GROUND ELECTRODE CONDUCTOR ENCLOSER NOT EFFECTIVELY BONDED DUE TO IMPAIRED K/O'S. IMPAIRED GROUND AT BOTH ENDS. OPEN ELECTRICAL SPLICES AT LIGHT FIXTURES. USE OF WRONG ELECTRICAL WIRING TO LIGHT. BLD. 2: BACK EAST SIDE ELECTRICAL CONDUIT NOT PROPERLY SUPPORTED. A/C WALL UNITS HAS BEEN INSTALLED, WOOD FRAMING DETERIORATED, MISSING IN AREAS, OPENINGS NOT PRPERLY SEALED. JUNCTION BOX TO SMALL FOR AS MANY WIRES ENTERING, CONDUIT NOT SECURED TO JUNCTION BOX, CONDUIT NOT SECURED TO STRUCTURE. JUNCTION BOX FALLING FROM WALL NOT PROPERLY SECURED. OVER HANG HAS HOLE FROM WHERE ADDED CIRCUITS AND CONDUIT HAS BEEN ADDED. MAIN DISCONNECT 1ST BOX, MISSING FRONT DEAD PLATE. 2ND BOX. BACK FEEDING SEVERAL BRANCH CIRCUITS. 30 AMP BREAKER-12 GAUGE WIRE SHOWS WHERE OVER HEATING AND MELTING OUTER COATING. MISSING FRONT DEAD PLATE. DOUBLE LUGGING ON GROUNDING BAR. GROUND WIRES IN JUNCTION NOT PROPERLY CAPPED. MIXING OF BREAKERS IN PANEL BOX. 3RD BOX. WIRE CONNECTIONS LOOSE. MISSING FRONT DEAD PLATE. MIXING OF BREAKERS IN PANEL BOX. 4TH BOX. ENCLOSER FOR MAIN GROUNDING ELECTRODE CONDUCTOR IS CROOKED CAUSING KNOCK OUT RINGS TO SEPERATE AND FURTHER CAUSING AN IMPEDANCE TO THE BONDING CONTINUITY. INTERIOR BUSSING WEATHERING, BREAKERS RUSTED, OPERATION IMPAIRED, BUSS BAR SCREWS RUSTED, WIRE COATING DETERIORATED, CRACKING, PEELING, BOX IS FALLING FROM WALL. CONDUIT NOT PROPERLY SECURED TO JUNCTION BOXES. ADDED ELECTRICAL CIRCUITS. APPEARS TO BE USING SINGLE POLE BREAKERS FOR 220 VOLTS. BLD. 3: HOT WATER TANK ROOM: FLUE PIPE NOT PROPERLY INSTALLED. HOT WATER TANK LACKS P.R.V. DRAIN LINE. ON BOTH TANKS. WATER LINES HAS BEEN INSTALLED. INSTALLED A HOLE IN L/B CONDULET FITTING USING CONDULET FITTING AS JUNCTION BOX, USE OF WRONG MATERIAL. 3 SEPERATE MAINS: 1ST BOX: NOT BONDED TO ENCLOSER. 2ND BOX: MAIN BREAKER PANEL BOARD NETURAL BAR NOT BONDED TO ENCLOSER. DOUBLE LUGGED ON BREAKER. 12 GAUGE WIRE INSTALLED ON 50 AMP BREAKER. CUT WIRES IN BOX, ENERGIZED THROUGH INDUCTANCE. (REMOVE) MISSING FRONT DEAD PLATE. 3RD BOX: USING WHITE WIRE AS HOT, NEEDS TO BE IDENIFIED. NETURAL BAR NOT GROUNDED. ELECTRODE GROUNDING CONDUCTOR NOT VISIBLE. (CHECK) BLD. 4: BLD. FEEDER COMMING FROM BLD 3 NOT PROPERLY SECURED AT ROOF TOP. CONDUIT NOT PROPERLY SECURED. CONNECTIONS TO BOXES NOT PROPERLY SECURED. ROOF TOP HAS SEVERAL AREAS WHERE CONDUIT HAS SEPERATED AND CUT IN WIRE CAUSING SPARKS WHEN MOVED. CONVENIENCE OUTLET DANGLING. ROOF TOP ON BLD HAS SEVERAL ISSUES TO BE ADDRESSED. ROMEX IN CONDUIT THEN CHANGES TO PLASTIC SEPERATING AT CONNECTIONS. OFFICE FRONT: BLD 4 USE OF WRONG WIRING FOR ALL EXTERIOR LIGHTING USING ZIP WIRE. OPEN SPLICES, OPEN CONNECTIONS. GTO CABLE NOT PROPERLY INSTALLED, NO DOUBLE BACKS BETWEEN NEON TUBING. HAZARDOUSLY INSTALLED. BEHIND OFFICE STILL BLD 4: ELECTRICAL ROOM: 4 SEPERATE BOXES: A, B1, B2, C BOX A: BACK FEEDING OF DISCONNECTED WIRES THROUGH IN BOX, OPEN ENDS. DOUBLE LUGGING OF BREAKERS. LOOSE CONDUCTOR CONNECTIONS. ARCING. MIXTURE OF BREAKERS, NOT COMPATABLE. ADDED ELECTRICAL CIRCUITS AND PANEL BOX. PANEL BOX HAS BEEN GROUNDED. WRONG. MISSING FRONT DEAD PLATE FILLER PLATES. LACKS PROPER LABELING. BOX B-1: BACK FEEDING DISCONNECTED LINES THROUGH INDUCTANCE. BUSS BAR SHOWS EVIDENCE OF CHARING. LACKS PROPER LABING. CONDUIT SEPERATED FROM PANEL BOX. MISSING FRONT DEAD PLATE FILL PLUGS. BOX B-2: BACKING FEEDING DISCONNECTED LINES. BOX HAS SEVERAL DISCONNECTED LINES ON INTERIOR. MISMATCHED BREAKERS. LACKS PROPER LABELING. CUT WIRE STRANDS ON FEEDER TO MAKE FIT, IMPROPER. FRONT DEAD PLATE MISSING FILLER BLANK COVERS. BOX C: SUB-PANEL HAS BEEN BONDED, WRONG. COMPLETE ROOM HAS ADDED ELECTRICAL CIRCUITS. EXTERIOR LIGHTING: OPEN SPLICES THROUGHOUT PROPERTY, USE OF WRONG MATERIAL, USING EXTENSION CORD WIRING TO SUPPLY ELECTRICAL POWER. ALSO CONDUICT OR PVC PIPING DOES TO CONNECT TO FIXTURES ALLOWING FOR EXPOSED WIRING, CONDUIT OR PVC PIPEING SEPERATING AT CONNECTION JOINTS. BLD.:4: ROOF TOP, MANY ISSUES. CONDUIT NOT PROPERLY SECURED, HAS BREAKS, SEPERATION, WHEN CONDUIT IS MOVED SPARKS DUE TO INSULATION BROKEN, CUT. ELECTRICAL DROP CONNECTION THAT GOES TO SIGN HAS BARE METAL CONNECTIONS. ALL ROOF TOP ELECTRICAL NEEDS TO BE REEVALUATED BY LICENSED CONTRACTOR. BLD 5: PANEL BOX DOUBLED LUGGED ON 7 SEPERATE BREAKERS. LACKS FRONT DEAD PLATE. EXPOSED WIRING DETERIORATING DUE EXPOSED TO SUN LIGHT.MISMATCHED BREAKERS. UNSUPPORTED CONDUIT. ENERGIZED OPEN BOXES. OPEN CONVENIENCE OUTLETS. 220 VOLTS INSTALLED WITH AN 110 VOLT RECEPTACLE. EAST SIDE OF BLD 5 HOT WATER TANKS REPLACED FROM ORIGINAL. WATER LINES ADDED, REPLACED FROM ORIGINAL. NOT PROPERLY INSTALLED. HOT WATER TANKS SITTING ON BRICKS WITH WOOD ON TOP. ROOF TOP SHOWS CRACKS DETERIORATION. INTERIOR ROOM SHOWS EVEDIENCE OF ROOF LEAK DUE TO WATER DETERIORATION. BLD 6: ROOF TOP : SEVERAL OPEN ENERGIZED JUNCTION BOXES. NORTH END OPEN AND EXPOSED ROMEX. ADDED ELECTRICAL CIRCUITS. BLD 7: ELECTRICAL SYSTEM: EXPOSED ROMEX. KNOCK OUTS MISSING. CONDUIT SEPERATED FROM BOXES. ADDED ELECTRICAL CIRCUITS. CONDUIT BROKEN IN 3 SEPERATE AREAS EXPOSING ROMEX. ZIP CORD BEING USED TO SUPPY PWER TO EXTERIOR LIGHTING. 3 SEPERATE PANEL BOXES. LACKS PROPER CLEARENCES. NEW PANEL BOX INSTALLED RATED FOR 125 AMPS INSTALLED WITH 200 AMP SERVICE. |
|
12/06/2005 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 12/6/05, RECIEVED CALL FROM UNIT 31 OCCUPANT DANNY STATING HAS NO HEAT, MADE APPT. WITH DANNY TO DO INSP. WILL BE AFTER 12:00. VISITED SITE, TOOK PICTURES, OCCUPANT ON SITE, MIKE MAINT. ON SITE, ANOTHER GENTLEMAN MIKE WORKING ON ELECTRIC IN UNIT 31, LISTENED TO OCCUPANTS COMPLAINTS ABOUT LACK OF HEAT AND LOSS OF ELECTRIC IN 1/2 THE UNIT, TURNED ON HEATER STARTED UP AND STARTED HEATING, DURNING CONVERSATION OCCUPANT STATED THAT WOULD ONLY RUN SHORT PERIOD OF TIME ABOUT 15 MINUTES, THEN WOULD NOT WORK ANY MORE, LET HEATER RUN FOR APPOX. 1 TO 1-15 MINUTES FOUND NO PROBLEM IN THIS TIME CYCLED ON AND OFF AS INTENDED, ROOM TEMP 70 CHECKED HEATER WHEN IN HEAT CYCLE TEMP 155, CHECKED WHEN IN FAN CYCLE STILL COOLING AT 101 TEMP, MIKE WORKING ON ELECTRIC HAS NOT FOUND PROBLEM AS OF YET, DONE INSP. ON INTERIOR OF UNIT, FOUND 220 RECEPTICLE FOR COOK STOVE HANGING FROM WALL, POSSIBLE INSTALLED WITH PERMIT. ALSO 3-PRONG CONVENIENCE OUTLET INSTALLED ON 2-WIRE SYSTEM, ALL ISSUES COMBINED WILL REQUIRE PERMIT, EXPLAINED TO MIKE MAINT. PERSON WORKING ON ELECT. IS NOT LICENSED, WILL REQUIRE LICENSED CONTRACTOR AND PERMIT FROM D.S.D. KITCHEN LIGHT MISSING PROTECTIVE COVERING, FULL STANDING REFRIG. KITCHEN SINK WATER SUPPLY LINES MISSING EMERGENCY SHUT OFF HANDLES, FRONT DOOR DOES NOT SEAL AS INTENDED. UNIT LACKS REQUIRED SMOKE DETECTOR. MANAGEMENT STATES THAT THEY OFFERED OCCUPANT ANOTHER UNIT TO STAY IN, OCCUPANT REFUSED, |
|
12/02/2005 | INSP - INITIAL CODE ENFORCMENT | Correction Required | 12/1/03, VISITED SITE, PER INSP. 2 RICK, ELECTRICAL ISSUES. TALKED WITH ON SITE MANAGER BINA, WHO STATED THAT ALL OF PROPERTY DOES HAVE ELECTRICAL SERVICE, DOES HAVE AN ISSUE IN UNIT NUMBER 31, LOST 1/2 THE ELECTRIC IN UNIT, HAS ALL READY CONTACTED AN ELECTRICAN, EXPECTED TO BE OUT TODAY TO MAKE REPAIRS, 12/1/05, ALSO SAME UNIT 31 HAD A PROBLEM WITH HEAT, HEAT/A/C UNIT HAD BEEN REPLACED, PER MANAGEMENT, WALKED EXTERIOR OF PROPERTY, AND LOOK AT ELECTRICAL SERVICE ENTRANCES, FOUND IN SEVERAL LOCATIONS, DOUBLE LUGGING OF BREAKERS, MISUSE OF WIRE SUCH AS 14 GAUGE WIRE ON 30 AMP BREAKERS, SEVERAL WIRES HAD BEEN CUT BUT NOT REMOVED, USE OF ZIP WIRE TO SUPPLY POWER TO EXTERIOR LIGHTING, 1 SERVICE ENTRANCE LOOSE FROM WALL, SEVERAL ADDED ELECTRICAL CIRCUITS THROUGHOUT PROPERTY, VISITED SITE IN LATE AFTERNOON, STARTING TO GET DARK, WILL RESCHEDULE TO DO COMPLETE INSP. OF EXTERIOR. TALKED WITH BINA (MANAGER) WHO STATED THAT OWNER WILL BE IN TOWN ON WED/THURSDAY, OF NEXT WEEK WOULD LIKE TO SCHEDULE WHEN OWNER IS THERE. BINA WILL CALL ME AND CONFIRM DATE BY END OF DAY FRIDAY 12/2/05. |