Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

REFERRED

Type:

RES: VACANT & ABANDONED
Address:

Entered Date:

11/23/2005

Applicant:

MORGAN ROY JR

Description:

REFERRAL FROM PROSECUTORS OFFICE VACANT AND NEGLECTED

Completed Inspections

Case Status: REFERRED
Case Number: T05DV01147
Case Description: RES: VACANT & ABANDONED
Total Completed Inspections - 3
End Date Description Inspector Results Comments
01/31/2006 INSP - INITIAL CODE ENFORCMENT HLOPEZ Approved VISITED SITE ON INITIAL INSPECTION. STRUCUTRE IS VACANT AND HAS SEVERAL WINDOWS BROKEN AND ALLOW EASY ACCESS INTO STRUCTURE, SOME WINDOWS ARE BOARDED. PROPERTY HAS FOUR FOOT CHAIN LINE FENCING SURROUNDING PROPERTY. LARGE AMOUNTS OF DRIED COMBUSTABLE VEGATATION AND VARIOUS AMOUNTS OF TRASH AND DEBRIS, LARGE PILE OF TIRES, BOAT, 12x60 MOBILE HOME, THREE POSSIBLE STORAGE WOODEN SHEDS IN DETERIORATED CONDITION. APPEARS ELECTRICAL UP-GRADE WAS IN PROCESS, EVIDENCE BY NEW TYPE WEATHER HEAD AND DISCONNECT PANEL. LARGE AMOUNTS OF UNPROTECTED WOOD FASIA AS WELL AS STORAGE SHEDS. PICTURES WERE TAKEN, WILL ADVISE PROJECT MANAGER FOR POSSIBLE VANS. ALSO ON PROPERTY IS OLD HORSE CORRAL, VACANT AND GUTTED BUS. LARGE AMOUNTS OF CONSTRUCTION DEBRIS IN BACK YARD.
04/03/2006 EMERGENCY CALL OUT HLOPEZ Approved NO CONTACT BY OWNER, CITATION TO BE ISSUED AFTER BOARDUP ISSE IS REVIEWED BY SUPERVISION CONTACTED SUPERVISOR, WENT OVER ISSUES REGARDING CHAIN AND LOCKS OF CHAIN LINK FENCING AND POSSIBLE ENTRY OPENING. BOTH AGREED TO HAVE BOARD UP CONTACTOR SECURE STRUCTURE AND INSTALL LOCKS. BEFORE ISSUING CITATION, CONTACT ES FOR PROGRESS WITH OPEN CASE AND COORDINATE SO AS NOT TO HAVE 2 CITATIONS FOR SAME VIOLATIONS.
04/06/2006 INSP - FOLLOW UP CODE ENFORCE HLOPEZ Approved CONTACTED BATHCREST BOARD UP CONSTRUCTOR REGARDING ON SITE MEETING TO SECURE MOBILE HOME & RESIDENT. SCHEDULE ON SITE MEETING AT 10:00 AM WITH JACK. MET ON SITE WITH BOARD UP CONTRACTOR, CHECKED KEYS IN DNR INSPECTOR SET FOR MASTER LOCK ON GATE, 2007 KEY OPENED LOCK, ENTERED PROPERTY TO ACCESS BOARD UP REQUIREMENTS. FOUND BACK DOOR OPEN & UNSECURED. ENTER UNIT & ANNOUNCED DNR INSPECTION ON SITE, WALKED INTERIOR OF STRUCTURE. KITCHEN HAS SOME FIRE DAMAGE EVIDENCE BY FIRE DAMAGED CEILING & WALL, EXPOSED ELECTRICAL CONDUCTOR STICKING OUT OF WALL, LARGE AMMOUNTS OF COMBUSTIBLES. PAPER GOOD THROUGHOUT INTERIOR OF STRUCTURE. BATHROOM WALL IS INA ASTATE OF COLLAPSE, WALL HAS BUCKLED IN, SEVERAL HOLES APPROX 3 FOOT X 12 INCHES AND ANOTHER APPROX 8 INCHES BY 12 INCHES. WINDOW FRAME IS BUCLED INFWARD. WAL IS PLASTER COOKED ADOBE & HAS LARGE AMMOUNTS OF EXPOSED ADOBE IN A DETERIORATED STATE IS ALSO CRAMBLING. WALL BUCKED IN APPROX 6 TO 8 INCHES INWARD. TEMPORARY FRAMING HAS BEEN INSTALLED ON EXTERIOR SIDED OF WALL TO SUPPORT ROOF ASSEMBLY. EXPLOSED ELECTRICAL CONDUCTOR AT BATHROOM DOOR ARE HANGING DOWN & LAYING ON FLOOR. LARGE AMMOUNT OF KITCHEN CEILING HAS COLLAPSED AS WELL AS CEILING IN BEDROOMS, FAMILY ROOM W/FIREPLACE AND APPEARS TO HAVE BEEN CAUSED BY ROOF LEAKING EVIDENCED BY LIGHT SHINING THROUGH. CHECKED ELECTRICAL DISCONNECT, MAIN BRAKER W/EVE FOUND OFF, BUT APPEARS ELECTRICAL SERVICE IS TO METER, CONTATCT TEP FOR DEV. FUNCTION OF CURRENT SERVICE, TEP CUSTOMER SERVICE TECH STATED SERVICE IS CURRENT. WALKED PROPERTY TO CHECK MOBILE HOME & OTHER STRUCTURE ON SITE MOBILE HOME ENTRY FOUND SECURED INTERIOR IS FULL OF DEBRIS & ALL WINDOW HAVE BEEN BROKEN TO ALLOW EASY ACCESS INTO STRUCTURE INSTRUCTED BOARD UP CONTRACTOR TO SECURE ALL OPENING IN MOBILE HOME & MAIN STRUCTURE. CHECKED OTHER STORAGE STRUCTURES ON SITE. 4 OTHER STRCUTRE ON SITE. ALL STRUCTURES ARE HEAVELY DETERIORATED AND 3 ARE IN A POSSIBLE STATE OF COLLAPSE. LARGE WOODEN STRUCTURE APPROX 12 x 16 LOCATED ON EAST SIDE OF PROPERTY HAS 2 WALL LISTING APPROX. 10 INCHES IN AN 8 FOOT SPAM HOLE STRUCTURES LEAN TO THE WEST, CENTER OF ROOF HAS COLLAPSED. 2 X 4 WOODS STUDS SUPPORTING ROOF STRUCTURE HAVE DETACHED FROM CAST WALL. CORRUGATED SHED, ROOF FRAME MUST BE OF 2 X 4 WOODEN STUDS, SPANNING OVER 4 FEET (APPROX 12 FEET) SEVERAL ARE IN AN ADVANCED STATE OF WOOD ROT, SEVERAL MUST BE SCABED TOGHETHER, OTHER HAVE ALREADY COLLAPSED. CENTER SUPPORT POST NOT ATTACHED TO 2 X 4 STUDS & ARE SHIMMED TO SUPPORT ROOF ASSEMBLY. CORRUGATED SHED MENSAVE APPROX 12 X 20 FEET AND CONTAINS LARGE AMMOUNT OF COMBUSTIBLE DEBRIS. DIRECTLY CAST OF SHED IS LARGE HOLE IN GROUND MENSAVING APPROX 12 FOOT BY 12 FOOT APPROX 3 FEET DEEP WITH CONCRETE DIVIDER MAY HABE BEEN SOME TYPE OF HOLDING TANK. OTHER SMALLER CORRUGATED SHED APPROX 8 FOOT BY 10 FOOT ALSO IN AN ADVANCED STATE OF DILAPIDATION, ONE SECTION ON APPROX 4 X 4 HAS COLLAPSE WOOD STUD BADLY WEATHERED ARE SPLITTING ALL ARE 2 X 4 STUDS PANING OVER FOUR FOOT. WILL REVIEW FINDING WITH SUPERVISOR REGARDING STRUCTURE IN MAIN STRUCTURE ON INTERIOR WALL SOUTEAST TO CORNER AND OTHER ON NORTHEAS SIDE BOTTOM OF WALL TO TOP OF WALL. ONE CRACK LOCATED ON NORTHEAST SIDE OF STRUCTURE APPEARS TO HOUSE BEES. BEE INFESTATION APPEARS TO BE IN WALL THE BEES CONSTANT BEE ACTIVITY WHILE ON SITE. PICTURE TAKEN.

Completed Activity Special Conditions

Case Description - RES: VACANT & ABANDONED
Case Number - T05DV01147
Case Status: REFERRED
Total Completed Case Activity Conditions: 3
Date Name
02/24/2006 NOTICE OF VIOLATION ISSUED
07/08/2009 VIOLATION CLOSED
06/08/2006 CITATION ISSUED

Documents

File Name Document Type  
5717 S 6TH AV DILAPIDATED STRUCTURES 2006-03-27 IMAGES VIEW
5717 S 6TH AV DILAPIDATED STRUCTURES 2006-03-27 0 IMAGES VIEW
5717 S 6TH AV DISABLED VEHICAL TRASH & DEBRIS 2006 IMAGES VIEW
5717 S 6TH AV TRASH & DEBRIS 2006-03-27 005.JPG IMAGES VIEW
5717 S 6TH AV TRASH & DEBRIS 2006-03-27 008.JPG IMAGES VIEW
5717 S 6TH AV TRASH & DEBRIS TIRES 2006-03-27 002 IMAGES VIEW
5717 S 6TH AV VACANT & UNSECURED TR 2006-03-27 01 IMAGES VIEW
5717 S 6TH AV VACANT & UNSECURED TR 2006-03-27 007 IMAGES VIEW
5717 S 6TH AV VANCANT & UNSECURED 2006-03-27 001.J IMAGES VIEW
5717 S 6TH AV VANCANT & UNSECURED WOP 2006-03-27 0 IMAGES VIEW
5717 S 6TH AV 2006-04-06 008.JPG IMAGES VIEW
5717 S 6TH AV COLLASPED CEILING 2006-04-06 038.JP IMAGES VIEW
5717 S 6TH AV COLLASPED CEILING 2006-04-06 004.JPG IMAGES VIEW
5717 S 6TH AV COMBUSTIBLE DEBRIS 2006-04-06 003.JP IMAGES VIEW
5717 S 6TH AV DETERIORATED & EXPOSED ABODE WALL 2 IMAGES VIEW
5717 S 6TH AV DETERIORATED & EXPOSED ABODE WALL 20 IMAGES VIEW
5717 S 6TH AV DILAPIDATED CEILING 2006-04-06 036. IMAGES VIEW
5717 S 6TH AV DILAPIDATED CEILING 2006-04-06 039. IMAGES VIEW
5717 S 6TH AV DILAPIDATED CEILING 2006-04-06 035.J IMAGES VIEW
5717 S 6TH AV DILAPIDATED STRUCTURE 2006-04-06 01 IMAGES VIEW
5717 S 6TH AV DILAPIDATED STRUCTURE 2006-04-06 02 IMAGES VIEW
5717 S 6TH AV DILAPIDATED STRUCTURE 2006-04-06 011 IMAGES VIEW
5717 S 6TH AV ELECT HAZ 2006-04-06 002.JPG IMAGES VIEW
5717 S 6TH AV ELECT HAZ 2006-04-06 040.JPG IMAGES VIEW
5717 S 6TH AV ELECTRICAL 2006-04-06 030.JPG IMAGES VIEW
5717 S 6TH AV ELECTRICAL 2006-04-06 031.JPG IMAGES VIEW
5717 S 6TH AV ELECTRICAL 2006-04-06 032.JPG IMAGES VIEW
5717 S 6TH AV ELECTRICAL 2006-04-06 029.JPG IMAGES VIEW
5717 S 6TH AV ELECTRICAL 2006-04-06 033.JPG IMAGES VIEW
5717 S 6TH AV FIRE DAMAGE 2006-04-06 001.JPG IMAGES VIEW
5717 S 6TH AV GRAFFITI 2006-04-06 034.JPG IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 014 IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 016 IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 025 IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 041 IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 012. IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 017. IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 021. IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 022. IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 024. IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 028. IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 009.J IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 010.J IMAGES VIEW
5717 S 6TH AV STRUCTURAL HAZARDS 2006-04-06 005.JP IMAGES VIEW
5717 S 6TH AV TRASH & DEBRIS 2006-04-06 023.JPG IMAGES VIEW
5717 S 6TH AV TRASH & DEBRIS 2006-04-06 026.JPG IMAGES VIEW
5717 S 6TH AV TRASH & DEBRIS 2006-04-06 037.JPG IMAGES VIEW
5717 S 6TH AV TRASH & DEBRIS 2006-04-06 020.JPG IMAGES VIEW
5717 S 6TH AV TRASH & DEBRIS 2006-04-06 015.JPG IMAGES VIEW
5717 S 6TH AV UNPROTECTED EXCAVATION 2006-04-06 01 IMAGES VIEW