Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case: T05DV01147

Parcel: 138100070


Addresses:

5717 S 6TH AV


Inspection Status: Approved

Inspection History: INSP - FOLLOW UP CODE ENFORCE

Case Number - T05DV01147

Inspection Description - INSP - FOLLOW UP CODE ENFORCE

Inspection Status - Approved

Date Description Inspector Results Comments
04/06/2006 INSP - FOLLOW UP CODE ENFORCE Approved CONTACTED BATHCREST BOARD UP CONSTRUCTOR REGARDING ON SITE MEETING TO SECURE MOBILE HOME & RESIDENT. SCHEDULE ON SITE MEETING AT 10:00 AM WITH JACK.
MET ON SITE WITH BOARD UP CONTRACTOR, CHECKED KEYS IN DNR INSPECTOR SET FOR MASTER LOCK ON GATE, 2007 KEY OPENED LOCK, ENTERED PROPERTY TO ACCESS BOARD UP REQUIREMENTS. FOUND BACK DOOR OPEN & UNSECURED. ENTER UNIT & ANNOUNCED DNR INSPECTION ON SITE, WALKED INTERIOR OF STRUCTURE. KITCHEN HAS SOME FIRE DAMAGE EVIDENCE BY FIRE DAMAGED CEILING & WALL, EXPOSED ELECTRICAL CONDUCTOR STICKING OUT OF WALL, LARGE AMMOUNTS OF COMBUSTIBLES. PAPER GOOD THROUGHOUT INTERIOR OF STRUCTURE. BATHROOM WALL IS INA ASTATE OF COLLAPSE, WALL HAS BUCKLED IN, SEVERAL HOLES APPROX 3 FOOT X 12 INCHES AND ANOTHER APPROX 8 INCHES BY 12 INCHES. WINDOW FRAME IS BUCLED INFWARD. WAL IS PLASTER COOKED ADOBE & HAS LARGE AMMOUNTS OF EXPOSED ADOBE IN A DETERIORATED STATE IS ALSO CRAMBLING. WALL BUCKED IN APPROX 6 TO 8 INCHES INWARD. TEMPORARY FRAMING HAS BEEN INSTALLED ON EXTERIOR SIDED OF WALL TO SUPPORT ROOF ASSEMBLY. EXPLOSED ELECTRICAL CONDUCTOR AT BATHROOM DOOR ARE HANGING DOWN & LAYING ON FLOOR. LARGE AMMOUNT OF KITCHEN CEILING HAS COLLAPSED AS WELL AS CEILING IN BEDROOMS, FAMILY ROOM W/FIREPLACE AND APPEARS TO HAVE BEEN CAUSED BY ROOF LEAKING EVIDENCED BY LIGHT SHINING THROUGH. CHECKED ELECTRICAL DISCONNECT, MAIN BRAKER W/EVE FOUND OFF, BUT APPEARS ELECTRICAL SERVICE IS TO METER, CONTATCT TEP FOR DEV. FUNCTION OF CURRENT SERVICE, TEP CUSTOMER SERVICE TECH STATED SERVICE IS CURRENT.
WALKED PROPERTY TO CHECK MOBILE HOME & OTHER STRUCTURE ON SITE MOBILE HOME ENTRY FOUND SECURED INTERIOR IS FULL OF DEBRIS & ALL WINDOW HAVE BEEN BROKEN TO ALLOW EASY ACCESS INTO STRUCTURE INSTRUCTED BOARD UP CONTRACTOR TO SECURE ALL OPENING IN MOBILE HOME & MAIN STRUCTURE.
CHECKED OTHER STORAGE STRUCTURES ON SITE. 4 OTHER STRCUTRE ON SITE. ALL STRUCTURES ARE HEAVELY DETERIORATED AND 3 ARE IN A POSSIBLE STATE OF COLLAPSE. LARGE WOODEN STRUCTURE APPROX 12 x 16 LOCATED ON EAST SIDE OF PROPERTY HAS 2 WALL LISTING APPROX. 10 INCHES IN AN 8 FOOT SPAM HOLE STRUCTURES LEAN TO THE WEST, CENTER OF ROOF HAS COLLAPSED. 2 X 4 WOODS STUDS SUPPORTING ROOF STRUCTURE HAVE DETACHED FROM CAST WALL. CORRUGATED SHED, ROOF FRAME MUST BE OF 2 X 4 WOODEN STUDS, SPANNING OVER 4 FEET (APPROX 12 FEET) SEVERAL ARE IN AN ADVANCED STATE OF WOOD ROT, SEVERAL MUST BE SCABED TOGHETHER, OTHER HAVE ALREADY COLLAPSED. CENTER SUPPORT POST NOT ATTACHED TO 2 X 4 STUDS & ARE SHIMMED TO SUPPORT ROOF ASSEMBLY.
CORRUGATED SHED MENSAVE APPROX 12 X 20 FEET AND CONTAINS LARGE AMMOUNT OF COMBUSTIBLE DEBRIS. DIRECTLY CAST OF SHED IS LARGE HOLE IN GROUND MENSAVING APPROX 12 FOOT BY 12 FOOT APPROX 3 FEET DEEP WITH CONCRETE DIVIDER MAY HABE BEEN SOME TYPE OF HOLDING TANK. OTHER SMALLER CORRUGATED SHED APPROX 8 FOOT BY 10 FOOT ALSO IN AN ADVANCED STATE OF DILAPIDATION, ONE SECTION ON APPROX 4 X 4 HAS COLLAPSE WOOD STUD BADLY WEATHERED ARE SPLITTING ALL ARE 2 X 4 STUDS PANING OVER FOUR FOOT. WILL REVIEW FINDING WITH SUPERVISOR REGARDING STRUCTURE IN MAIN STRUCTURE ON INTERIOR WALL SOUTEAST TO CORNER AND OTHER ON NORTHEAS SIDE BOTTOM OF WALL TO TOP OF WALL. ONE CRACK LOCATED ON NORTHEAST SIDE OF STRUCTURE APPEARS TO HOUSE BEES. BEE INFESTATION APPEARS TO BE IN WALL THE BEES CONSTANT BEE ACTIVITY WHILE ON SITE. PICTURE TAKEN.
03/24/2006 INSP - FOLLOW UP CODE ENFORCE Violation NO PROGRESS/ NO CONTACT BY OWNER
VISITED SITE ON FW/UP INSPECTION, NO PROGRESS HAS BEEN MADE ON REMOVEAL OF ACCUMLATED TRASH & DEBRIS. STRUCTURES STILL REMAINS UNSECURED. OWNER HAS NOT ATTEMPTED TO CONTACT DNR INSP.
RESEARCH IN PERMITS PLUS SCREEN SHOWS OWNER SIGNED FOR CERTIFIED MAIL ON 2/21/06
WILL ATTEMPT TO MAKE CONTACT WITH OWNER THROUGH CITY COMMUCATION. IF NO RESPONCE BY OWNER CITATION WILL BE ISSUED. PICTURES WERE TAKEN.