Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

11/10/2005

Applicant:

POSTRZECH JOHN

Description:

LEAKS IN SHOWER AREA, WATER DAMAGE TO WALLS, ROACH INFESTATION.

Outstanding Inspections

Case Number: T05DV01066
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 11
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected
NPO - UNSECURED BUILD OR STRUC None Not Inspected
VIOL(BL) - DETACHED STRUCTURES None Not Inspected
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected
VIOL(EL) - CIRCUITS None Not Inspected
VIOL(EL)-SUBPANELS/DISCONNECTS None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
VIOL(EL) - FIXTURES None Not Inspected
NPO(PL)-WATER HEATERS None Not Inspected
11/28/2005 NPO(HC)-COOLING JHURD Correction Required 11/28/05, CALLED OCCUPANT LEROY, TALKED WITH LEROY WHO STATED THAT HE IS NOT AT HOME RIGHT NOW WILL BE HOME ABOUT 1 PM, TOLD LEROY THAT I WILL DO OTHER CALLS THEN STOP BY THIS AFTERNOON, LEROY STATED WOULD BE HOME REST OF AFTERNOON, ARRIVED ON SITE APPOX. 3 PM, NO ONE WAS HOME LEFT NO ONE HOME LETTER IN DOOR, 5 DAYS TO RESPOND, WHILE ON SITE FOUND SEVERAL OTHER ISSUES, SUCH AS EXPOSED WOOD ON FRONT ENTRY DOOR, BROKEN LIGHT BULBS WITH EXPOSED FILIMENTS, PROTECTIVE GLOBE COVERS MISSING, APPEARS TO HAVE ADDED ELECTRICAL CIRCUITS, PINIC AREA, LAUNDRY ROOM, SOME EXTERIOR LIGHTING, ELECTRICAL BOX MISSING K/O'S, CONDUIT NOT PROPERLY SUPPORTED, REPLACEMENT OF HOT WATER TANK, FLUE PIPE NOT PROPERLY SEALED, ADDED WATER LINES/OR REPLACED WATER LINES, LAUNDRY FACILITY HAS OPEN AND EXPOSED ROMEX.
12/20/2005 INSP - INITIAL CODE ENFORCMENT JHURD Correction Required 12/1/05 VISITED SITE, TOOK PICTURES, MET WITH OCCUPANT WHO ALLOWED ENTRY, FOUND FRONT ENTRY DOOR HAS BEEN REPLACED BUT NOT FINISHED, FRONT DOOR LACKS PROPER WEATHER STRIPPING, DOUBLE KEY DEAD BOLT INSTALLED ON FRONT DOOR, LIGHT SWITCH MISSING PROTECTIVE COVER PLATE, LIVING ROOM CONVENIENCE OUTLET LOOSE FROM WALL, COOKL STOVE FLEX GAS SUPPLY LINE RUNS THROUGH CABINET AND RUNS INTO STOVE CABINET, NOT PROPERLY INSTALLED. CONVENIENCE OUTLET BEHIND COOK STOVE MISSING PROTECTIVE COVERING, CLOSET SHOWS DETERIORATED DRYWALL DUE TO LEAK IN WALL, DRYWALL WET, DRYWALL AROUND BATHROOM SHOWER HEAD DETERIORATED, BATHROOM WINDOW CRANK DOES NOT OPERATE AS INTENDED, BATHROOM DOOR HAS HOLE, LIVINGROOM DRYWALL HAS BEEN REPLACED IN AREA, HAS NOT BEEN COMPLETELY FINISHED, LACKS PROTECTIVE COVERINGS, SMOKE DETECTOR DOES NOT OPERATE.

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV01066
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
10/19/2006 INSP - FOLLOW UP CODE ENFORCE JHURD Approved RESEARCH SHOWS OWNER RECEIVED EXTENSION ON COMBO PERMIT T06CM00847 NOW EXPIRES ON 04/08/07 BEING ACTIVE IN SYSTEM (PERMITS) DNR HAS NO JURISDICTION UNTIL PERMIT EXPIRES.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV01066
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
04/25/2006 CONTACTED BY PHONE
12/21/2005 NOTICE OF VIOLATION ISSUED
08/15/2008 VIOLATION CLOSED
04/25/2007 PERMITS EXPIRE

Documents

File Name Document Type  
232 W FLORES 8 16 06 T05DV01066 01.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 02.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 03.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 04.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 05.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 06.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 07.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 08.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 09.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 10.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 11.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 12.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 13.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 14.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 15.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 16.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 17.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 18.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 19.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 20.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 21.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 22.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 23.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 24.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 25.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 26.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 27.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 28.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 29.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 30.JPG IMAGES VIEW
232 W FLORES 8 16 06 T05DV01066 31.JPG IMAGES VIEW
232 W FLORES 6 1 07 048.JPG IMAGES VIEW
232 W FLORES 6 1 07 049.JPG IMAGES VIEW
232 W FLORES 6 1 07 050.JPG IMAGES VIEW
232 W FLORES 6 1 07 051.JPG IMAGES VIEW
232 W FLORES 6 1 07 052.JPG IMAGES VIEW
232 W FLORES 6 1 07 053.JPG IMAGES VIEW
232 W FLORES 6 1 07 054.JPG IMAGES VIEW
232 W FLORES 6 1 07 055.JPG IMAGES VIEW
232 W FLORES 6 1 07 056.JPG IMAGES VIEW
232 W FLORES 6 1 07 057.JPG IMAGES VIEW
232 W FLORES 6 1 07 058.JPG IMAGES VIEW
232 W FLORES 6 1 07 059.JPG IMAGES VIEW
232 W FLORES 6 1 07 060.JPG IMAGES VIEW
232 W FLORES 6 1 07 061.JPG IMAGES VIEW
232 W FLORES 6 1 07 062.JPG IMAGES VIEW
232 W FLORES 6 1 07 063.JPG IMAGES VIEW
232 W FLORES 6 1 07 064.JPG IMAGES VIEW
232 W FLORES 6 1 07 065.JPG IMAGES VIEW
232 W FLORES 6 1 07 066.JPG IMAGES VIEW
232 W FLORES 6 1 07 067.JPG IMAGES VIEW
232 W FLORES 6 1 07 068.JPG IMAGES VIEW
232 W FLORES 6 1 07 069.JPG IMAGES VIEW