Case: T05DV00922
Case Details
Entered Date:
10/14/2005
Applicant:
CASAGRANDE THOMAS R & APRIL 40% & BEAN
Description:
STOVE SHOCKS, LEAK UNDERNEATH KITCHEN SINK, LIVING ROOM WINDOW DOES NOT WORK, DAMAGE FROM ROOF LEAK IN FRONT OF WINDOW, WALL DAMAGED.
Completed Inspections
Case Status: COURTCMP
Case Number: T05DV00922
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/05/2005 | INSP - INITIAL CODE ENFORCMENT | HLOPEZ | Approved | VISITED SITE ON INITIAL INSPECTION OF UNIT #7. NO ANSWER, MESSAGE MACHINE CAME ON. NO MESSAGE WAS LEFT. ATTEMPTED CONTACT WITH TENANT AT UNIT #7. UNIT 7 WAS FOUND VACANT AND SECURED. WALKED COMPLEX, DID FIND SEVERAL MIN-HOUSING ISSUES THROUGH OUT PROPERTY. ISSUES ARE AS FOLLOWS PERMITS REQUIRED POSSIBLE W/O/P-HOUSE STRUCTURE ON NORTH WAST SIDE OF PROPERTY APPEARS TO HAVE HAD A GARAGE CONVERTED TO A LIVING SPACE. STRUCTURE ATTACHED TO MAIN STRUCTURE HAS ASPHALT PAVING LEADING RIGHT TO STRUCTURE. THI WOOD SIDING CAME ALL WAY DOWN WALL ON SOUTH SIDE, NEW TYPE WINDOWS HAVE BEEN INSTALLED, MAIN STRUCUTRE EXISITING CURRENT WINDOW ARE WOD FRAMES ALSO NEW ROOF TOP HEAT PUMP WITH FIRE PLACE, SHEET METAL VENT AND WEATHER PROOF COLLOR APPEAR TO HAVE BEEN RECENTLY INSTALLED. PLUMBING SYSTEM 1) UNITS #3 AND 4 ARAGE AREA. WASH BASIN PLUMBING IS CLOGGED WATER DOES NOT DRAIN INTO SEWER 2) EXTERIOR HOT WATER HEATER ENCLOSURE ARE IN A DETERIORATED STATE, ROOF IS CAVING IN AND DOORS ARE MISSING AND NOT ATTACHED TO ENCLOSURE 3) VENT SYSTEM (FLUE) ARE NOT SECURED PROPERLY 4) LAUNDRY ROOM-DRYER NOT HOOKED UP TO EXHAUST VENTS, LARGE AMOUNTS OF COMBUSTABLE LINT HAVE BEEN ALLOWED TO ACCUMULATE ALONT WALL AND POSE A FIRE SAFTEY ISSUE 5) RECEPTACLE LACKING COVER PLATE BEHIND WASHING MACHINE LAUNDRY ROOM: INTERIOR FEATURES 1) INTERIOR WALLS HAVE NOT BEEN MAINTAINED, SEVERAL LARGE HOLES IN WALLS 2) ENTRY DOOR HAS BEGUN TO DETACH FROM HINGES AND WILL NOT CLOSE PROPERLY, CYLINDER FOR DOOR KNOB MISSING, DOOR STYLE SPLIT 3) INTERIOR CLOSET DOOR PRIVACY LOCK HAS BEEN DAMAGED 4) WINDOW MISSING ON SOUTH WALL (WINDOW FRAME AND GLASS) ACCESSORY STRUCTURE SECURITY WROUGHT IRON FENCING ON SECOND FLOOR NORTH SIDE ARE LOOSE AS WELL AS BOTTOM OF STAIR WELL AT EAST SIDE AND POSE A SAFTEY HAZARD TO THE OCCUPANTS. CORNER POST NOT ANCHORED TO SLAB. ELECTRICAL SYSTEM-POOL AREA 1) HAZARDOUS EXPOSED ELECTRICAL CONDDUCTOR AT NORTH SIDE OF FENCING, INSIDE PUMP AREA, AT DISCONNECT PANEL 2) NON-WEATHER PROOF J-BOX FOR PORCH AREA LIGHT FIXTURE 3) POOL CONTROL BOX NOT SECURED TO FENCING 4) WEATHER PROOF COVER LACKING A RECEPTACLE IN POOL EQUIPMENT AREA ELECTRICAL SYSTEM-4 UNITS ORIGINAL 30 AMP SYSTEM HAS HAD ALTERATION DONE, ALTERATION DONE HAS VOIDED GRANDFATHER RIGHTS. 1) UNDER FUSE PROTECTION 2) UNDER SIZE WIRE 3) PROTECTIVE GROMET LACKING AT PENATRATION 4) UNPROTECTED CLOTH ELCETRIAL CONDUCTORS ARE NOT INSTALLED IN CONDUIT AND UNDER 8 FEET. APPEARS ELECTRICAL CONDUCTOR TO RUN THROUGH ATTIC SPACE THEN RUNS DOWN INTO GROUND THEN TO 2 UNITS ON WEST SIDE OF PROPERTY. WILL REVIEW PICTURES WITH ELECTRICAL INSPECTOR. 5) A/C WINDOW UNITS HAVE BEEN INSTALLED APPEAR NOT TO BE INSTALLED ON REQUIRED SEPERATE CIRCUIT. 6) NEWER TYPE ELCTRICAL DISCONNECT HAS BBEN INSTALLED , IS NO LISTED AS SERVICE EQUIPMENT 7) GFIC RECEPTACLE IN GARAGE AREA AT UNIT #1 3&4 ARE NOT WORKING CORRECTLY AND LACK WEATHER PROTECTION 8) RECEPTACLE FOR COOLERS ARE NOT WEATHER PROOF AND ARE DETERIORATED STATE POSSIBLE WORK WITH OUT PERMITS (STRUCTURAL) HOUSE STRUCTURE ON NORTH EAST CORNER HAS HAD NEW HEAT PUMP INSTALLED AND FIRE PLACE INSTALLED RECENTLY AS EVIDENCED BY NEW SHEET METAL COMPONENTS. RESEARCH WILL BE CONDUCTED FOR REQUIRED PERMITS AND INSPECTIONS. HOUSE STRUCTURE APPEARS TO HAVE HAD A GARAGE CONVERTED TO HABITABLE SPACE WITH ELECTRICAL, EVIDENCED BY NEWER TYPE WINDOWS, 1/2 WALL ON SOUTH SIDE WALL T1-11 WOOD SIDING AND ASPHALT RUNS RIGHT UP TO WALL ON EAST SIDE. RESEARCH WILL BE CONDUCTED FOR REQUIRED PERMITS AND INSPECTIONS. CARPORTS UNIT 3 & 4 SILL PLATES ARE NOT INSTALLED AS REQUIRED, 2x6 LAYING SIDE WAY FOR BEARING WALL, 2"x6" SCABED TOGETHER APPEARS TO HAVE BEEN CUT OUT INTO WALLS IWTH OUT APPROVED ATTACHMENT HARDWARE. SOME BEAMS HAVE BEEN NAILED AND LACKS PROPER ATTACHMENT HARDWARE. SUPPORT POST LACKING IN MIDDLE OF STRUCTURE. |
| 07/12/2006 | EMERGENCY CALL OUT | HLUCCA | Approved | CONTUCTED RESEARCH IN CITY OF TUCSON PERMITS PLUS PROGRAM. RESEARCH FOUND NO PERMIT IS ISSUED STATUS, CONTACTED OWNER ANN, SHE STATED THAT ELECTRICAL CONTRACTOR HAS BEEN HIRED & SHOULD OF HAD PERMIT ALREADY. INFOREMED HER OF REASERCH CONDUCTED & NO ELECTRICAL PERMIT FOR UP GRADE & REWIRE OF STRUCTURES WERE ON FILE. SHE STATED SHE WOULD CONTACT A ELECTICAL CONTRACTOR TODAY AS WELL AS ARCITECT. INFORMED HER NEW PROCEDURESS HAVE BEEN INSERTED INTO DNR PROCESS & COULD NO LONGER GRANT EXTENTION, INFORMED HER CITATION WILL BE ISSUED & EXPLAINED THE CITAION PROCESS. SHE STATED SHE WOULD CONTACT ELECTRICL CONTRACTOR & HAVE PERMITS ISSUED TODAY. DNR INSPECTOR INFORMED HER HE NEEDED TO BE INFORMED IF PERMITS ARE ISSUED TODAY 07-11-06. CONTACTED ELECTRICAL CONTRACTOR ASKED IF HE HAD PULLED REQUIRED PERMIT. HE STATED NO NOT YET, BUT WAS DEFINITELY GOING TO DO THE REQUIRED WORK. HE STATED HE WAS OUT OF TOWN ON ANOTHER JOB & WOULD CONTACT SOMEONE IN HIS OFFICE TO PULL PERMITS. STATED PERMITS WILL BE PULLED BY 07-13-06. DUE TO 2 EXTENTION WAS GIVEN & NOT UNDER WAY CITATION HES BEEN ISSUED. |
| 09/28/2006 | INSP - FOLLOW UP CODE ENFORCE | HLOPEZ | Approved | COURT FW/UP NOTES STORED IN SIRE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00922
Case Status: COURTCMP
Total Completed Case Activity Conditions: 2
| Date | Name |
| 12/21/2005 | CONTACTED BY PHONE |
| 03/10/2006 | NOTICE OF VIOLATION ISSUED |