Case: T05DV00642
Case Details
Entered Date:
09/09/2005
Applicant:
CAREY DORTHEA 50% & VERNON KENNETH W 50%
Description:
CRACKS ON SOUTSIDE AND NORTHSIDE OF FOUNDATION, HOUSE SETTLING IN BECAUSE OF WATER TAKEN FROM AQUIFERS.
Case Violations
Case Number: T05DV00642
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 1
Violation Date | Code Statue |
---|---|
05/02/2006 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |
Outstanding Inspections
Case Number: T05DV00642
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 15
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EMERGENCY CALL OUT | None | Not Inspected | ||
NPO - UNSECURED BUILD OR STRUC | None | Not Inspected | ||
VIOL(BL) - ATTACHED STRUCTURES | None | Not Inspected | ||
VIOL(BL) - LIVING AREAS | None | Not Inspected | ||
NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
VIOL(EL) - CIRCUITS | None | Not Inspected | ||
VIOL(EL)-SUBPANELS/DISCONNECTS | None | Not Inspected | ||
NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
VIOL(EL) - FIXTURES | None | Not Inspected | ||
VIOL(EL) - OTHER | None | Not Inspected | ||
NPO(PL)-PLUMBING SYSTEM & FX | None | Not Inspected | ||
NPO(PL)-GAS SUPPLY/CONNECT | None | Not Inspected | ||
VIOL(PL) - FIXTURES | None | Not Inspected | ||
NPO - EGRESS | None | Not Inspected | ||
NPO - SMOKE ALARMS | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV00642
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/29/2005 | INSP - INITIAL CODE ENFORCMENT | JORTA | Approved | MET WITH INSPECTOR R. VIDAL ON SITE TO GO OVER THE ELECTRICAL HAZARDS THAT HE HAD OBSERVED THE DAY BEFORE. I WAS ABLE TO CONFIRM THE ELECTRICAL VIOLATIONS THAT INSPECTOR VIDAL HAD WRITTEN-UP ALONG WITH ADDITIONAL VIOLATIONS. THE AREA WITH THE MOST EXTREME HAZARDS WERE AT THE ELECTRICAL SERVICE AREA AND THE ELECTRICAL SUB-PANEL, WHICH IS LOCATED REMOTE OF THE MAIN SERVICE, BUT WITHIN THE CONTIGUOUS STRUCTURE. THE OVERHEAD SERVICE CONSISTS OF FOUR ELECTRIC METERS WITH THEIR RESPECTIVE DISCONNECTS. THE DISCONNECTS VARIED IN AMPACITY RATINGS FROM THIRTY, TO ONE HUNDRED AMPS. THE METERS WERE ALL FED FROM A SINGLE GUTTER, WHICH WAS FOUND TO BE IN A DILAPIDATED CONDITION, RUSTED OUT AND NOT OF RAINTIGHT CONSTRUCTION, FURTHERMORE THIS GUTTER HAS WIRING THAT CONTAINS BOTH UTILITY CONDUCTORS AS WELL AS CUSTOMER OR PREMISES WIRING, WHICH IS CONTRARY TO THE TECHNICAL CODES. THERE ARE VARIOUS RISERS EMERGING FROM THE GUTTER AND IN PARTICULAR ONE OF THE RISERS WAS FEEDING AN AREA LOCATED DIRECTLY SOUTH APPROXIMATELY ONE HUNDRED FEET WHICH COULD HAVE BEEN USED FOR AN R.V. UNIT. AS INSPECTOR VIDAL POINTED OUT, TWO OF THE METERS WERE NOT IN USE, (DISCONNECTED) AND THE OTHER TWO WERE ON. ONE METER WAS FEEDING A NEWER CIRCUIT BREAKER TYPE OF DISCONNECT SWITCH RATED AT SEVENTY AMPS MAXIMUM WITH OVERCURRENT PROTECTION AT TWENTY AMPS. THIS TWENTY AMP SERVICE DISCONNECT WAS USED TO SUPPLY ONE SIDE OF THE MAIN HOUSE THAT WAS ITS' OWN APARTMENT AT ONE TIME, BUT SOMEONE CUT A HOLE THROUGH THE CMU WALL. THE APARTMENT WAS NOT USED AS A RESIDENCE, BUT WAS METERED SEPERATELY BECAUSE THIS WAS BEING USED AS A MUSIC AND RECORDING STUDIO IN WHICH THE ELECTRIC USAGE WAS METERED SEPARATE AND PAID FOR BY THE BAND OR GROUP MEMBERS. THE MAIN SERVICE TO THE HOUSE IS RATED AT ONE HUNDRED AMPS AND THIS IN TURN FEEDS THE SUB PANEL FOR THE MAIN HOUSE WHICH IS LOCATED APPROXIMATELY FIFTY FEET AWAY AND ON THE EXTERIOR. THE FEEDER CABLE IS A LISTED TYPE S.E., WHICH IS WEATHERED AND EXPOSING THE CONCENTRIC STRANDING OF THE "GROUNDED" CONDUCTOR, EXPOSING THE DELICATE ALUMINUM STRANDS SUBJECTING THE WIRE TO BREAKING OFF. THE CONCENTRIC LAY OF THIS TYPE OF CABLE IS HELICALLY WOUND AT THE OUTER CIRCUMFERENCE AND IF THE CABLE IS NOT PHYSICALLY PROTECTED THEN THERE IS A DANGER OF LOOSING THE NEUTRAL CONDUCTOR AND CREATING ABNORMALLY HIGH OR LOW VOLTAGES WHICH BURN UP EQUIPMENT, INJURE PERSONELL OR CAUSE OTHER HAZARDS. THE SERVICE EQUIPMENT WAS ALSO IMPROPERLY GROUNDED, WITH THE GROUNDING ELECTRODE CONDUCTOR LOOSELY ATTACHED TO A WATER LINE AND LEFT HANGING IN FREE AIR. THE PLYWOOD USED AS A BACKING FOR THE SERVICE WAS WEATHERED AND LOOSE. THE MAIN SERVICE FOR THE HOUSE WAS BY FAR THE MOST DANGEROUS. THE ONE HUNDRED AMP SERVICE DISCONNECT WAS SO DETERIORATED THAT THE MECHANICAL COMPONENTS WERE WORN OUT AND NOT USEABLE WHICH CREATED AN UNSAFE SITUATION OF ANYONE NOT BEING ABLE TO SHUT OFF THE POWER IN CASE OF EMERGENCY AND PERHAPS WORST YET, IF SOMEONE WOULD TRY TO RE-ENERGIZE THE HOUSE, THERE WOULD CERTAINLY BE A LARGE FLASH CREATED BY AN ARC AND WILL CAUSE SEVERE BURNS OR OTHER SERIOUS INJURY. THERE WERE SEVERAL OTHER AREAS THROUGHOUT THE HOUSE WITH VIOLATIONS SUCH AS OPEN AND EXPOSED WIRES AND SPLICES, HANGING UNPROTECTED ROMEX WIRES, LIGHTING FIXTURES INSTALLED WITHOUT THE REQUIRED JUNCTION BOXES. AS PREVIOUSLY MENTIONED, IMPROPER GAS CONNECTIONS, STUCK WINDOWS, LACK OF SMOKE DETECTORS ALONG WITH OTHER ITEMS AS MENTIONED BY INSPECTOR VIDAL. I ISSUED A NOTICE OF VIOLATION WITH ZERO DAYS FOR COMPLIANCE PRIMARILY BECAUSE OF THE POWER THAT HAD TO BE SHUT OFF AND OTHER CONDITIONS LIKE THE GAS THAT WAS SHUT OFF BECAUSE OF S.W. GAS DETECTING A LEAK. THE OWNER WAS THERE TO ACCEPT AND SIGN THE NOTICE. INSPECTOR VIDAL WAS TAKING CARE OF THE BOARD UP AND ALL OF THE OTHER ISSUES SUCH AS HOUSING AND COMMUNICATING WITH THE TENANTS AND EXPLAINING HOW AND WHEN THEY COULD ENTER TO REMOVE THEIR PERSONAL ITEMS. MR. VIDAL DID CALL TRAVELER'S AID TO SET UP TEMPORARY HOUSING FOR THE TENANTS, BUT WHEN THE TENANTS ARRIVED FOR THIS SERVICE IT WAS DECLINED BECAUSE OF CERTAIN RESTRICTIONS IMPOSED UPON THE WOULD-BE TENANTS THAT WAS INCOMPATIBLE WITH THEIR LIFESTYLE. |
12/15/2005 | INSP - FOLLOW UP CODE ENFORCE | JORTA | Approved | SITE INSPECTION FOLLOW-UP was made after I had talked with Mr. Vernon as he is contemplating on moving in. I spoke with the electrical contractor and he did tell me that he is also running the range and the water heater. At this time there is no permanent heating possibly due to extensive repairs that may be needed because the gas was shut off. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00642
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
10/11/2005 | CONTACTED BY PHONE |
02/10/2006 | CONTACTED BY MAILING |
11/15/2005 | NOTICE OF VIOLATION ISSUED |
12/19/2005 | MESSAGE LEFT ON OFFICE PHONE |
02/22/2006 | PRENOTICE OF VIOLATION |