Case: T05DV00569
Case Details
Entered Date:
08/11/2005
Applicant:
OLSON PAUL C & KATHY 50% & CAULKINS
Description:
RV HOOKED UP TO SEWER AND CORDS IN DRIVEWAY
Outstanding Inspections
Case Number: T05DV00569
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T05DV00569
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/11/2005 | INSP - INITIAL CODE ENFORCMENT | GGOODMAN | Approved | VISITED SITE, UPON ARRIVAL FOUND RV PARKED TO THE SOUTH OF STRUCTURE, IT ALSO APPEARED THAT STRUCTURE WAS BEING RENNOVATED, EVIDENCED BY A PILE OF TRASH ALSO TO THE SOUTH OF STRUCTURE WHICH INCLUDED THE DOORS AND OTHER FIXTURES THAT CAME OUT OF THE STRUCTURE.KNOCKED ON FRONT DOOR OF STRUCTURE, RECEIVED NO ANSWER,BUT DID FIND BY LOOKING THROUGH THE FRONT SLIDING GLASS DOOR THAT THE STRUCTURE WAS UNDER REMODEL AS DFLOORING HAD BEEN REMOVED, KITCHEN CABINETS HAD BEEN REMOVED, AS WELL AS MOST LIGHTING FIXTURES AND BATH FIXTURES. IT ALSO APPEARED AS THOUGH HOUSE HAD BEEN PAINTED, NEW DOORS HAVE BEEN ADDED, AND NEW FLOORING BEING PREPARED TO BE PUT DOWN, EVIDENCED BY THE THINSET AND GROUT IN THE LIVINGROOM AREA. NEW TOILETS AND VANITY FIXTURES WERE ALSO LYING INSIDE THE STRUCTURE, WITH CEILING FANS LYING OUTSIDE. KNOCKED ON DOOR OF RV, RECEIVED NO ANSWER. FROM THE FRONT DOOR OF HOUSE STRUCTURE FOUND ELECTRICAL CORDS RUNNING TO THE RV, BUT CORDS WERE UNPLUGGED. DID FIND A GARDEN HOSE RUNNING TO AND CONNECTED TO THE RV. FROM THE DRIVERS SIDE OF RV FOUND ELECTRICAL ( APPROX THE SIZE OF A 10-4 CORD), RUNNING TO THE BACKYARD AREAWHERE CORD WAS PLUGGED INTO AN ELECTRICAL BOX LYIG ON THE GROUND. MULTIPLE HAZARDOUS ELECTRICAL LINES WERE FOUND ON THE GROUND, ( ROMEX CONNECTED TO WEATHER EXPOSED ELECTRICAL BOXES). EXPOSED ROMEX RAN FROM THE BOXES APPROXIMATELY 15 FEET TO A CARPORT AREA, INTO CONDUIT AT THAT POINT TO A DISCONNECT SERVICE UNDER THE CARPORT, AND ON THE STORAGE SECTION WALL. THERE WERE EXPOSED JUNCTION BOXES ALONG THE CONDUIT RUN WITH EXPOSED WIRING AND WIRE NUTS CONNECTING WIRES. EXPOSED ROMEX LYING ON THE GROUND DID NOT APPEAR TO BE DIRECT BURIAL TYPE WIRE. CALLED AND SPOKE TO INSPECTOR 2, WENT OVER ISSUES OF THE ENTIRE PROPERTY INSIDE AND OUT. RICK SUGGESTED POSTING UNIT FOR HAZARDOUS ELECTRICAL. WE AGREED TO POST UNIT FOR WORK WITHOUT PERMITS AND HAZARDOUS ELECTRICAL. RICK ALSO SUGGESTED THAT I BE SURE OR TRY TO FIND OUT IF RV WAS SELF CONTAINED, NO GENERATOR ANY WHERE. DID WALK THE RV AREA FOUND NO EVIDENCE THAT WASTE WAS BEING DUMPED ON THE PROPERTY. POSTED STRUCTURE FOR HAZARDOUS ELECRICAL AND PERMITS REQUIRED.LEFT A NOTE PERTAINING TO RV AND DID MENTION THAT RV COULD NOT BE USED FOR LIVING CONDITIONS UNLESS RV CAN BE USED IN A SELF CONTAINED MANNER. PICTURES WERE TAKEN. SPOKE WITH NEIGHBOR AT 1122 CAMINO MIRA FLORES, GEORGINA RIVERAS, WHO MENTIONED THAT SHE DID NOT KNOW WHO WAS LIVING AT THE PROPERTY , HOWEVER HER FATHER HAS SEEN PEOPLE WORKING AT THE STRUCTURE AS THERE HAD BEEN A DUMPSTER ONSITE FOR A WHILE BUT HAD SINCE BEEN REMOVED. FOUND NOBODY HOME AT 1115 & 1130 CAMINO MIRA FLORES. |
| 09/23/2005 | INSP - FOLLOW UP CODE ENFORCE | GGOODMAN | Approved | VISITED SITE, KNOCKED ON FRONT DOOR, RECEIVED NO ANSWER. FOUNT WORK HAS CONTINUED ON THE HOUSE ITSELF EVIDENCED BY THE NEWLY INSTALLED FRONT DOOR, TILE INSTALLED THROUGHOUT THE HOUSE, AND NEWLY INSTALLED CEILING FANS. FOUND THAT THE ELECTRICAL ROMEX LYING ON THE GROUND, CONNECTED TO THE RV HAD BEEN REMOVED, HOWEVER THE JUNCTION BOX THAT THE ROMEX WAS CONNECTED TO REMAINED UNCOVERED (NO COVER PLATE) LEAVING WIRES AND WIRE NUTS EXPOSED TO THE ELEMENTS. FOUND THAT THE TRASH AND DEBRIS LEFT LYING AROUND THE PROPERTY HAD BEEN PICKED UP AND REMOVED FROM THE PROPERTY. AND FOUND THAT THE RV HAD BEEN REMOVED FROM THE SOUTHEAST DRIVE AND PLACED IN THE SOUTHWEST DRIVE, SOUTH OF THE EXISTING CARPORT. CHECKED PERMITS PLUS TO VERIFY THAT PERMIT HAD BEEN SECURED. FOUND PERMIT WAS IN APPLIED STATUS, MONEY HAD BEEN PAID FOR PERMIT, BUT WAS STILL BEING REVIEWED BY DAVE WITT. SENT EMAIL TO ZONING ASKING IF OWNER WAS IN VIOLATION FOR NOT REMOVING RV. NO POWER OR WASTE LINES WERE SEEN CONNECTED TO THE RV. PICTURES WERE TAKEN. WILL COMPLETE FOLLOW BEFORE CLOSING CASE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00569
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 08/12/2005 | CONTACTED BY PHONE |
| 05/08/2006 | VIOLATION CLOSED |