Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

07/29/2005

Applicant:

WEST ORA G & KARCHER BILLIE JEANNE TR

Description:

COMPLAINT: COOLER, WINDOWS DON'T OPEN, ELECTRICAL THAT GOES OUT. FURNACE - GAS COMPANY WON'T LIGHT.

Outstanding Inspections

Case Number: T05DV00535
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T05DV00535
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/09/2005 INSP - INITIAL CODE ENFORCMENT GGOODMAN Approved VISITED SITE, MET WITH TENANT MYRA ROMO, WHO MENTIONED SHE HAD LIVED AND RESIDENCE FOR APPROX 2 YRS. HAD ALWAYS ASKED DAUGHTER OF OWNER, BILLY TO MAKE ALL THE REPAIRS NECCESARY, BUT OFTEN DEALT WITH BILLIES HUSAND LARRY WHO OFTEN REFUSED TO DEAL WITH REPAIRS.MENTIONED THAT LARRY OFTEN BECAME UPSET THAT SHE WAS CALLING IN COMPLAINTS. MYRA MENTIONED THAT SHE BECAME AFRAID IF SOMETHING WENT WRONG, BECAUSE SHE FELT GUILTY IF A COMPLAINT HAD TO BE CALLED IN. MYRA ALSO MENTIONED THAT HER BIGGEST CONCERN WAS THE COOLER AND THE FACT THAT AIR FROM THE DUCT WORK LEFT A BLACK RESIDUE AROUND THE SUPPLY GRILLES. MYRA MENTIONED THAT HER SON HAS BEEN TO THE EMERGENCY ROOM WITH A BAD CONSTANT COUGH AND HAS BEEN NAUSEATED, AND DOCTORS HAVE NOT BEEN ABLE TO FIGURE OUT WHAT HAS BEEN CAUSING THE COUGHING AND NAUSEA. I EXPLAINED TO MYRA THAT I WOULD BE CONDUCTING A THOROUGH INSPECTION, HOW IT AND THE NOV WORKED, MY FINDINGS ARE AS FOLLOWS: >ELECTRICAL BATHROOM RECEPTICLE ON NORTH WALL SHOWS OPEN GROUND. >RECEPTICLE IN SOUTHWEST BEDROOM, WEST WALL LACKS RECEPTICLE COVER. >SOUTH EAST BEDROOM RECEPTICLE, LIGHT SWITCH COVER IS BROKEN. >ONLY PART OF KITCHEN LIGHT IS WORKING AT THIS TIME. >FRONT CARPORT LIGHT HAS BEEN ADDED. WIRING TO LIGHT HAS BEEN RUN FROM FRONT PORCH LIGHT, WIRING LEFT EXPOSED. >REAR PORCH LIGHT SWITCH NOT PROPERLY INSTALLED, MUST BE IN WEATHER PROOF BOX. >EXTERIOR SERVICE PANEL AS BEEN DOUBLE AND TRIPLE LUGGED. APPPEARS PANEL HAS BEEN ADDED TO. PERMITS WILL BE REQUIRED AS WELL AS A SERVICE UPGRADE. INTERIOR FEATURES: >WINDOWS THROUGHOUT THE STRUCTURE LACK WINDOW CRANKS, HAVE CRANKS THAT DO NOT OPERATE PROPERLY, AND HAVE WINDOW LOCKS THAT DO NOT OPERATE PROPERLY OR DO NOT OPERATE AT ALL. >KITCHEN CABINETS HAVE BEEN MODIFIED FOR THE MICROWAVE, LEAVING BOTTOM SHELF OUT WHICH IS NEEDED TO HELP PROPERLY SUPPORT THE MICROWAVE. >KITCHEN CABINET DOORS ARE DIFFICULT TO OPEN AND CLOSE DUE TO SWELLING AND BEING PAINTED TOO MANY TIMES. >KITCHEN POCKET DOOR NOT WORKING AS INTENDED,COULD NOT PULL DOOR OUT OF FRAME. PLUMBING: >FLOOR HEATER IN HALLWAY IS NO LONGER WORKING, WAS TAGGED BY SOUTHWEST GAS AS NOT SERVICABLE. MECHANICAL EQUIPMENT: >BATH FAN NOT WORKING PROPERLY, WHEN TURNED ON A LOUD RUMBLING OCCURS. >WIRING FOR MICROWAVE IMPROPER. CORD HAS BEEN SPLICED. >COOLER NOT WORKING PROPERLY.AIR FLOW NOT APPROPRIATE,NORTH SIDE OF COOLER HAS BEEN COVERED WITH PLASTIC. WORK WITHOUT PERMITS: >APPEARS LIGHTS IN LIVINGROOM HAVE BEEN ADDED. >APPEARS REAR PORCH HAS BEEN ADDED, WORK WITHOUT PERMITS.
05/23/2006 INSP - FOLLOW UP CODE ENFORCE GGOODMAN Approved VISITED SITE, APPEARED UNIT HAD BEEN RE-RENTED. CALLED AND SPOKE TO OWNER MR KARCHER WHO MENTIONED ALL ITEMS ON NOV HAD BEEN ABATED, WOULD BE OK TO IN SPECT AS LONG AS NEW TENANT JOHN AGREED. KNOCKED ON DOOR, MET WITH TENANT JOHN, EXPLAINED I SPOKE WITH MR KARCHER WHO MENTIONED IT WOULD BE OK TO INSPECT AS LONG AS HE AGREED AND THAT I HAD ONLY 5 ISSUES THAT NEEDED CHECKING. JOHN AGREED. * QUICKLY CHECKED REMAINING ITEMS FOUND ALL ISSUES HAD BEEN ABATED, ITEMS CHECKED OFF ON NOV AND DATED. NO PICTURES WERE TAKEN EXCEPT FOR THE FRONT OF THE HOUSE, REAR YARD. CLOSE CASE!!

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T05DV00535
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
01/31/2006 NOTICE OF VIOLATION ISSUED
05/26/2006 VIOLATION CLOSED
08/22/2005 INSPECTOR CONTACTED BY PHONE

Documents

File Name Document Type  
2006-05-23 167.JPG IMAGES VIEW
2006-05-23 168.JPG IMAGES VIEW
2006-05-23 169.JPG IMAGES VIEW
2005-08-05 012.JPG None VIEW